Retrofit Questionnaire V16-2-06
Delem
General Information
Brand of machine
What hydraulic system is used
(include copy of hydraulic switching diagram in
case of a non Delem control!)
Backgauge configuration
Which brand controller is currently on the machine
If Delem controller, which type and Serial Number
Delem controller specific information
General:
What is the software version of the controller
What KO-table is installed
Input Voltage 230V or 110V
Arm mounting bolts distance: 95mm or 135mm
I/O Boards:
7280- Please complete the type number (e.g. 7280-002)
7281-
7282- Please complete the type number
7289- Please complete the type number
Please complete the type number
1 Y1 & Y2 Proportional valve interface:
Internal valve amplifier, LVDT 3-12V feedback, coil 24V 0,8A (Hoerbiger)
External Valve amplifier, -10V..+10V (Bosch, Rexroth, etc )
2 Y1 & Y2 encoder interface (see notes 2,3 and 4):
12 pole FRB -> 5V Differential Ended
12 pole Binder -> 5V Single Ended and 5V Differential Ended
DK-FRB/M-BIN/F
3 Proportional pressure valve interface:
Current controlled, Coil 24V 1,5A
Voltage controlled, output 0V..+10V
4 X encoder interface (see note 1):
9 pole Sub-D -> 5V Single Ended, 5V Differential Ended and 12V Single Ended
12 pole FRB -> 5V Single Ended and 5V Differential Ended
12 pole Binder -> 5V Single Ended and 5V Differential Ended
7 pole Binder -> 5V Single Ended
7 pole Binder -> 12V Single Ended
DK-FRB-SUBD
DK-BIN12/F-SUBD9/M-5S
DK-BIN7/F-SUBD9/M-5S
DK-BIN7/F-SUBD9/M-12S
5 Aux encoder interface:
9 pole Sub-D -> 5V Single Ended, 5V Differential Ended and 12V Single Ended
12 pole FRB -> 5V Single Ended and 5V Differential Ended
12 pole Binder -> 5V Single Ended and 5V Differential Ended
7 pole Binder -> 5V Single Ended
7 pole Binder -> 12V Single Ended
DK-FRB-SUBD
DK-BIN12/F-SUBD9/M-5S
DK-BIN7/F-SUBD9/M-5S
DK-BIN7/F-SUBD9/M-12S
6 Aux axis function (see note 5):
X2, R, R1, R2, Z, Z1 or Z2
Part support unit
E v e r y t h i n g u n d e r c o n t r o l
Retrofit Questionnaire V16-2-06
Delem
7 Function outputs:
Function output F1-F2-F3 floating
Function output F1-F2-F3 common connected to GND (J13,J14 SET on X-Y board)
8 Crowning device:
Motorized Wila crowning -> A>, A< with potentiometer feedback
Hydraulic crowning -> 0
Not mounted
Notes:
1) If the machine has an AC controlled X-axis, this must be changed to a Servo controlled type
(closed loop control, +/-10V speed signal, encoder feedback)!
2) In case of 12V linear scale, replace it by a 5V type
3) In case of 40u linear scale, replace it by a 20u type
4) In case of a single linear scale application contact Delem
5) If the machine is equipped with add-on cards DI-43 (7259-00x) or DI-44 (7357-00x), these
cards should be replaced by the DI-01. In this case please indicate if you need the HSB bus
connection cables and the required lengths
6) The DA-65R does not accept the old DLA file format. Please contact Delem for conversion
possibilities of products and tools. The machine parameters should programmed manually.
Remarks:
..+
10V analog output
The DA-65R is standard supplied with a 12-pole female FRB connector for the Y1 and Y2 linear
scale interface. For the X and AUX axis a 9-pole SUBD connector is standard available. Listed below
are the optional parts, which can be ordered together with the DA-65R.
Order Information (DA-65R optional parts)
Y-axis conversion cables (length is 0,25 mtr):
Qty Order code Cable ID Description
DK-FRB/M-BIN/F 1112-001 Enc. conv. cable for 12p FRB-male to 12p BIN-
female
DK-FRB-split-F-2M 1041-001 Splitter cable for single scale application
X-axis conversion cables (length is 0,25 mtr):
Qty Order code Cable ID Description
DK-BIN7/F-SUBD9/M-12S 1110-001 Enc. conv. cable for 7p BINDER-female to 9p
SUBD-male 12V
DK-BIN7/F-SUBD9/M-5S 1110-003 Enc. conv. cable for 7p BINDER-female to 9 p
SUBD-male 5Vse
DK-BIN12/F-SUBD9/M-5S
DK-FRB-SUBD
1110-002 Enc. conv. cable for 12p BINDER-female to 9p
SUBD-male 5Vse/5Vde
1126-001 Enc. conv. cable for 12p FRB-female to 9p
SUBD-male 5Vse/5Vde