Deep SEA Electronics 8810 User Manual

TYPICAL WIRING DIAGRAM
A larger diagram is available in the operators manual.
Deep Sea Electronics Plc.
Deep Sea Electronics I
8706
8708
TOLL FREE (USA only) : Tel: 1 866 636 9703
Email: dsesales@deepseausa.com
Web: www.deepseausa.com
DIMENSIONS AND MOUNTING
DIMENSIONS
240.0mm x 181.1mm x 41.7mm (9.4” x 7.1” x 1.6”)
PANEL CUTOUT
220mm x 160mm (8.7 x 6.3)
Accessing the Front Panel Configuration Editor.
Ensure the engine is at rest and the module is in STOP mode by pressing the Stop/Reset
Stop button and
If a module security PIN has been set, the PIN number request is then shown .
, the first ‘#’ changes to ‘0’. Press
(right) when the first digit is correctly entered. The digit you have just entered will now
The other digits of the PIN number. You can press
after editing the final PIN digit, the PIN is checked for validity. If the
enter the PIN.
• If the PIN has been successfully entered (or the module PIN has not been enabled), the editor is
to enter edit mode. The parameter begins to flash to indicate that
change the parameter to the required value.
. The parameter
To exit the editor at any time, press and hold the
EDITING A PARAMETER
(right)
to cycle to the parameter within the section you have chosen.
to enter edit mode. The parameter begins to flash to indicate that
change the parameter to the required value.
. The parameter
To exit the editor at any time, press and hold the
DEEP SEA ELECTRONICS
IN ST AL LATI ON I NST RU CT IO NS
nc.
NOTE: When the editor is visible, it is automatically exited after 5 minutes of inactivity to ensure
The PIN number is automatically reset when the editor is exited (manually or automatically) to
More comprehensive module configuration is possible
NOTE: The contents of the tables overleaf may differ depending on the actual module configuration.
053-137
8810
ISSUE 1
button.
Press and hold the the
Press
value.
Press show ‘#’ for security.
one of the previous digits.
When is pressed number is not correct, you must re-
displayed.
To edit the parameter, press you are editing the value.
Press the up or down buttons to
Press to save the value
Enter the editor as described above.
Press the (up) (down) and
Then press (up) or (down)
To edit the parameter, press you are editing the value.
Press the up or down buttons to
Press to save the value
Tick button together.
(up) or (down) to adjust it to the correct
(left) if you need to move back to adjust
ceases flashing to indicate that it has been saved.
or button.
to cycle to the section you wish to view/change.
ceases flashing to indicate that it has been saved.
For flat surface mounting in a Type 1 enclosure to meet UL requirements
Tel:+44 (0)1723 890099
Fax: +44 (0)1723 893303
Email: support@deepseaplc.com
Web: www.deepseaplc.com
Phone: +1 (815) 316-
Fax: +1 (815) 316-
:
security.
NOTE: ensure security.
NOTE: contact us for further details
or button.
using the PC configuration software. Please
ACCESSING THE “MAINTENANCE” EDITOR
b SectiT
ADJUSTABLE PARAMETERS
-
Front Panel Configuration Editor
Section
Parameter
Detail of Parameter
Parameter Action
Values
s
s
KVAr Fixed Export
kVAr Share
None
Oil Pressure Low Oil Pressure Shutdown Trip 0.00 Bar
Inputs
Timers
Generator
Engine
Alt. Config Options
Coolant Temperature High Coolant Alarms Pre-Alarm Trip 00 Deg C
Fuel Level Fuel Usage Alarm Running Rate Up / down
Start Timers Start Delay Remote Start Off Load
Stopping Timers Stopping Timers Return Delay s
Display Page Timer mm: ss
Generator Options AC System
Generator Current Current Options CT Primary (L1,L2,L3,N) 0A
Generator Voltage Under Voltage Alarms Alarm Trip 0%
Generator Frequency Under Frequency Alarms Alarm Trip
Generator Power Overload Protection Overload Protection Trip 0% (0 kW)
Synchronising Load Control
Engine Options Overspeed Options Overspeed Overshoot 0%
Speed Settings Under Speed Alarm Enable Enabled / Disabled
Plant Battery Under Voltage Alarms Under Volts Enable Enabled / Disabled
Default Configuration
Low Coolant Alarms Pre Alarm Trip 00 Deg C
Start Timers Preheat s
Generator Rating KW Rating 0 KW
Earth Fault Earth CT Primary 0A
Over Current Alarm IDMT Alarm Enabled / Disabled
Short Circuit Trip 0% 0.0A
Nominal Voltage Nominal Voltage 0V Over Voltage Alarms Pre-alarm ttrip 0V
Nominal Frequency Nominal Frequency 0.0Hz Pre-Alarm Trip
Ramp Speed Ramp Speed 0.0 %/s Load Demand Calling For More Sets 0 %
Insufficient Capacity Action
Droop Enable Enabled / Disabled
Over Speed Alarm Trip 0000 RPM
Over Voltage Alarms Over Volts Enable Enabled / Disabled
Charge Alt Alarm Alarm Enable Enabled / Disabled
Charge Alt Pre-Alarm Pre-Alarm Enable Enabled / Disabled
.
Warning Trip 0.00 Bar
Electrical Trip 00 Deg C Shutdown Trip 00 Deg C
Stopped Rate Up / down
Remote start On Load Telemetry Start s
Cranking Time s Crank Rest Time s Smoke Limit s Smoke Limit Off s Safety on Delay s Warming up Timer s
Cooling Time mm:ss Fail To Stop Delay 0s Gen Transient Delay 0s
Scroll Timer s
kVAr Rating 0 kVAr
CT Secondary 5Amp / 1 Amp 5 / 1 Amp Full Load Rating 0A
Trip Action Enabled / Disabled Trip Percentage 0%
Trip 0% 0.0A
Pre-Alarm Trip 0A
Alarm Trip 0V Pre-Alarm Trip
Alarm Trip
Reverse Power Trip (Delay) 0kW (0.0 s)
Reactive Load Mode
Calling For Less Sets 0 %
Overshoot Delay s
Percent 0.0%
Alarm Trip 0000 RPM Warning Enable Enabled / Disabled Warniing Trip 0000 RPM
Pre-Alarm Enable Enabled / Disabled Pre-Alarm Trip 0000 RPM
Under Volts Delay mm:ss Under Volts Pre-Alarm 0.0v
Over volts Delay mm:ss Over Volts Pre-Alarm 0.0v
Alarm Trip 0.0v Alarm Delay s
Pre-Alarm Trip 0.0v Pre-Alarm Delay s
3 Phase, 4 wire Delta 2 Phase, 3 Wire L1-L3 2 Phase, 3 Wire L1-L2 3 Phase, 3 Wire Single Phase, 2 Wire 3 Phase, 4 Wire
0.0Hz
0.0Hz
0.0Hz
0.0Hz
Warning / Shutdown / None / Indication / Electrical Trip
Alternative Configuration 3 Alternative Configuration 2 Alternative Configuration 1 Main Configuration
Request
Activati on
Press
Button
Press (up) or (down) buttons together. Press ,(Up) or(down) (right) to cycle to the
Parameter you wish to action.
Description Action
USB Stick Removal Request Override Starting Alarms Request Clear AMF Alarm Clear Manual Fuel Pump Inactive Min / Max Session Reset Request Cancel Telemetry
To exit the editor at any time, press and hold the Tick button.
ACCESSING THE ‘RUNNING’ CONFIGURATION EDITOR
The ‘running’or editor can be entered while the engine is running. All protections remain active if the engine is running while the running editor is entered.
Press and hold the button to enter the running editor.
ADJUSTABLE PARAMETERS (Running Configuration Editor) Enter the editor as described
above.
Press the (up) or (down) buttons to cycle to the section you wish to view / change.
To Edit the parameter press the Tick button to enter edit mode. The parameter begins to flash to indicate that
Press the (up) or (down) buttons to change the parameter to the required value.
Press and hold Tick button to exit the “Running Configuration Editor”.
Section Parameter Detail Of Parameter Values
Language
Generator
Display
Engine
Time
you are editing the value.
Press the Tick button to save the value. The parameter ceases flashing to indicate that it has
Language other English (United Kingdon) Running Load Power Factor 0%
0.00pf 0kVAr Load Parallel Power 0% 0kW Load Priority Load Priority 1 Options Starting Alarms Disabled / Enabled Decoupling Test Mode Disabled / Enabled Voltage Voltage Adjust 0% Frequency Frequency Adjust 0% Press/ Temp Units Pressure kPA / PSI / Bar Temperature Deg F / Deg C Volume Units Volume Litre / Gallons US / Gallons (UK) Display LCD Backlight 0% AC Graphics AC Min / Max Enable Enabled / Disabled AC Meter Enable Enabled / Disabled THD Screen Enable Enabled / Disabled Engine Multi Meter Mode Enabled / Disabled Tier 4 Screen Enabled / Disabled Alarm Alarm Alert Box Enabled / Disabled Summary Summary Area Graphic Bars / Connectors Home Commissioning Screens Enabled / Disabled Speed Adjust
Module Time hh:mm:ss Module Date DD/ MM/ YYYY Date Format MM/ DD/ YYYY OR DD/ MM/ YYYY MM/ DD/ YYYY OR DD/ MM/ YYYY
Up / Down buttons
been saved.
Loading...