DeDietrich KALIKO TWH Split FS 270 E, KALIKO TWH Split FS 200 E User Manual

Page 1
KALIKO SPLIT
TWH Split FS 200 E TWH Split FS 270 E
User Guide
Thermodynamic water heater
en
NIE-A-011
Page 2
Dear Customer,
Thank you very much for buying this Appliance.
Please read this manual carefully before using your appliance. Keep this document in a safe place for future reference.
In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this.
We hope you will receive many years of satisfactory service.
Page 3
37638216-02 - 19062015 KALIKO SPLIT
Table of Contents
Table of Contents
1 Safety Instructions
1.1 General safety instructions .......................................................................................................................... 5
1.2 Recommendations ...................................................................................................................................... 6
1.3 Specific safety instructions .......................................................................................................................... 8
1.4 Liability ........................................................................................................................................................ 9
1.4.1 Manufacturer's liability .......................................................................................................................................... 9
1.4.2 Installer's liability................................................................................................................................................... 9
1.4.3 User's liability........................................................................................................................................................ 9
1.5 Safety data sheet: R-134a refrigerant fluid ............................................................................................... 10
1.5.1 Product identification .......................................................................................................................................... 10
1.5.2 Identification of hazards ..................................................................................................................................... 10
1.5.3 Composition of / Information on the ingredients ................................................................................................. 10
1.5.
4 First Aid............................................................................................................................................................... 10
1.5.5 Fire prevention measures ................................................................................................................................... 11
1.5.6 In the event of accidental spillage ...................................................................................................................... 11
1.5.7 Handling ............................................................................................................................................................. 11
1.5.8 Personal protection ............................................................................................................................................ 12
1.5.9 Regulations ........................................................................................................................................................ 12
1.6 Internet site .................................................................................................................................................. 12
2 About this manual
2.1 General ..................................................................................................................................................... 13
2.2 Documentation available ........................................................................................................................... 13
2.3 Symbols used ............................................................................................................................................ 13
2.3.1 Symbols used in the manual .............................................................................................................................. 13
2.3.2 Symbols used on the appliance ......................................................................................................................... 13
3 Technical specifications
3.1 Homologations .......................................................................................................................................... 14
3.1.1 Certifications ....................................................................................................................................................... 14
3.1.2 Directive 97/23/EC .............................................................................................................................................14
3.1.3 Test before leaving the factory ........................................................................................................................... 14
3.2 Technical data ........................................................................................................................................... 15
3.2.1 Characteristics of the appliance ......................................................................................................................... 15
3.2.2 Heating time of the thermodynamic water heater according to air temperature................................................. 16
3.2.3 Operation and limits of the thermodynamic water heater ................................................................................... 16
4 Description of the product
4.1 General description ................................................................................................................................... 17
4.2 Operating principle .................................................................................................................................... 17
4.3 Main components ...................................................................................................................................... 18
4.3.1 Domestic hot water tank ..................................................................................................................................... 18
4.3.2 Outdoor unit........................................................................................................................................................ 19
4.4 Description of the display .......................................................................................................................... 20
4.4.1 Description of the control keys ........................................................................................................................... 20
4.4.2 Description of the display ................................................................................................................................... 20
Page 4
7638216-02 - 190620154 KALIKO SPLIT
Table of Contents
5 Using the appliance
5.1 Using the control panel ............................................................................................................................. 21
5.1.1 First time commissioning .................................................................................................................................... 21
5.1.2 Setting the time .................................................................................................................................................. 22
5.1.3 Setting the operating ranges .............................................................................................................................. 23
5.1.4 Setting domestic hot water set point .................................................................................................................. 25
5.1.5 Electrical back-up ............................................................................................................................................... 26
5.1.6 Recommissioning procedure after a power outage ............................................................................................ 26
6 Switching off the appliance
6.1 Switching off the installation ...................................................................................................................... 27
6.2 Prolonged absence ................................................................................................................................... 27
7 Maintenance
7.1 General ..................................................................................................................................................... 28
8 Troubleshooting
8.1 Messages (Ex and Px type code) ............................................................................................................. 29
8.1.1 Messages on the display .................................................................................................................................... 29
9 Scrapping / Recycling
9.1 General ..................................................................................................................................................... 30
10 Appendices
10.1 Declaration of Conformity .......................................................................................................................... 31
10.2 ErP information ......................................................................................................................................... 32
10.2.1 Product data sheet: thermodynamic water heater ............................................................................................ 32
Page 5
57638216-02 - 19062015 KALIKO SPLIT
1 Safety Instructions
1.1 General safety instructions
1 Safety Instructions
Danger
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are given correct supervision or instruction on using the appliance in complete safety and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance should not be carried out by children without adult supervision.
Danger
In the event of a refrigerant leakage:
1 Do not use a naked flame, do not smoke, do
not operate electrical contacts or switches (doorbell, light, motor, lift, etc.).
2 Open the windows. 3 Switch off the appliance. 4 Avoid contact with the refrigerant. Danger of
frost injuries.
5 Locate the probable leak and seal it
immediately.
Danger of electric shock
Before any work, switch off the mains supply to the heat pump.
Caution
Installation of the thermodynamic water heater and the heat pump must be done by a qualified professional in accordance with prevailing local and national regulations.
Warning
Do not touch the refrigeration connection pipes with your bare hands while the heat pump is running. Danger of burn or frost injury.
Page 6
7638216-02 - 190620156 KALIKO SPLIT
1 Safety Instructions
Warning
Take precautions with the domestic hot water. Depending on the settings of the thermodynamic water heater, the domestic hot water temperature may exceed 65°C.
Caution
Only genuine spare parts may be used.
Warning
Only qualified persons are authorised to assemble, install and maintain the installation.
1.2 Recommendations
Note
● The appliance is intended to be permanently connected to the water mains.
● Maximum / minimum water inlet pressure: See chapter on Technical Specifications.
● The pressure limiter device must be regularly operated in order to remove limescale deposits and ensure that it is not blocked.
● Draining: Shut off the domestic cold water inlet. Open a hot water tap in the installation and then open the valve on the safety unit. When the water stops flowing, the appliance has been drained.
● A pressure reducer (not provided) is necessary when the the supply pressure exceeds 80% of the calibration of the safety valve or safety unit and it must be located upstream of the appliance.
● As water may flow out of the discharge pipe on the pressure limiter device, the discharge pipe must be kept clear and open.
● Connect the pressure limiter device to a drainage pipe, kept open to the air, in a frost-free environment, and at a continuous downward gradient.
Caution
Install the domestic hot water tank in a frost-free environment.
Caution
Do not neglect to service the thermodynamic water heater. Service the thermodynamic water heater regularly to ensure that it runs correctly.
Page 7
77638216-02 - 19062015 KALIKO SPLIT
1 Safety Instructions
Caution
If the home is unoccupied for a long period and there is a risk of frost, drain the domestic hot water tank.
Note
Keep the domestic hot water tank and the outdoor unit accessible at all times.
Note
Never remove or cover the labels and data plates affixed to appliances. Labels and data plates must be legible throughout the entire lifetime of the appliance.
Immediately replace damaged or illegible instructions and warning stickers.
Note
Remove the casing only to perform maintenance and repair work. Put the casing back in place after maintenance and repair work.
Note
Keep this document close to the place where the appliance is installed.
Caution
Do not make any modifications to the thermodynamic water heater without the written consent of the manufacturer.
Warning
In accordance with the NFC 15.100 electrical safety standard,
only qualified professionals are
permitted access to the inside of the appliance.
Warning
● Ensure correct earthing.
● Install the outside unit on a solid, stable
structure capable of bearing its weight.
● Do not install the thermodynamic water heater
in a place that has an atmosphere with a high salt content.
● Do not install the thermodynamic water heater
in a place exposed to steam and combustion gases.
● Heating water and domestic water must not
come into contact with each other.
Page 8
7638216-02 - 190620158 KALIKO SPLIT
1 Safety Instructions
1.3 Specific safety instructions
Warning
Refrigerant fluid and pipes:
● Use only R-134a refrigerant fluid to fill the
system.
● Use tools and pipe components especially
designed for use with R-134a refrigerant fluid.
● Use copper pipes deoxidised with
phosphorus to carry the refrigerant fluid.
● Use beading to guarantee the tightness of the
connections.
● Store the refrigerant connection pipes away
from dust and humidity (risk of damage to the compressor).
● Cover both ends of the pipes until the
beading process.
● Do not use a load cylinder.
● Regarding information on installation on
the appliance, electrical connection and connection of the water circuit, refer to the paragraphs below in this manual.
● Regarding information on handling, servicing
and scrapping the appliance, refer to the paragraphs below in this manual.
Note
In order to limit the risk of being scalded, the installation of a thermostatic mixing valve on the domestic hot water flow pipes is recommended.
Page 9
97638216-02 - 19062015 KALIKO SPLIT
1 Safety Instructions
1.4 Liability
1.4.1 Manufacturer's liability
Our products are manufactured in compliance with the requirements of the various Directives applicable. They are therefore delivered with the any markings and documents necessary. In the interests of the quality of our products, we strive constantly to improve them. We therefore reserve the right to modify the specifications given in this document. Our liability as manufacturer may not be invoked in the following cases:
● Failure to abide by the instructions on installing the appliance.
● Failure to abide by the instructions on using the appliance.
● Faulty or insufficient maintenance of the appliance.
1.4.2 Installer's liability
The installer is liable for the installation and initial commissioning of the appliance. The installer must abide by the following instructions:
● Read and follow the instructions given in the manuals provided with the appliance.
● Install the appliance in compliance with prevailing legislation and standards.
● Carry out initial commissioning and any checks necessary.
● Explain the installation to the user.
● If maintenance is necessary, warn the user of the obligation to check the appliance and keep it in good working order.
● Hand over all manuals to the user.
1.4.3 User's liability
To guarantee optimal operation of the appliance, the user must respect the following instructions:
● Read and follow the instructions given in the manuals provided with the appliance.
● Call on qualified professionals to handle installation and initial commissioning.
● Have the installer explain the installation.
● Have the required inspections and maintenance carried out by a qualified installer.
● Keep the instruction manuals in good condition close to the appliance.
Page 10
7638216-02 - 1906201510 KALIKO SPLIT
1 Safety Instructions
1.5 Safety data sheet: R-134a refrigerant fluid
1.5.1 Product identification
■ Name of the refrigerant fluid R-134a
■ Emergency call:
- Anti-poison Centre INRS/ORFILA: +33 (0) 1 45 42 59 59.
1.5.2 Identification of hazards
■ Effects harmful to health:
- The vapours are heavier than air and may lead to asphyxia owing to reduced oxygen levels.
- Liquefied gas: Contact with the liquid may cause serious frost and eye injuries.
■ Product classification: This product is not classified as a "hazardous preparation" according to European Union regulations.
1.5.3 Composition of / Information on the ingredients
■ Chemical nature: 1,1,1,2-Tetrafluoroethane R-134a.
■ Ingredients that may lead to hazardous situations:
Substance name Concentration CAS number CE number Classification GWP
1,1,1,2-Tetrafluoroethane R-134a 100% 811-97-2 212-377-0 1300
1.5.
4 First Aid
■ If inhaled: Evacuate the subject from the
contaminated area and take him into the open air. If feeling unwell: Call a doctor.
In the event of contact with the skin: Treat frost injuries like burns. Rinse with copious amounts of water, do not remove clothing (risk of adhesion to the skin).
■ If skin burns appear, call a doctor immediately.
In the event of contact with the eyes: Rinse immediately in water, holding the eyelids well apart (at least 15 minutes). Consult an ophthalmologist immediately.
Page 11
117638216-02 - 19062015 KALIKO SPLIT
1.5.5 Fire prevention measures
■ Appropriate extinguishing agents: All extinguishing agents can be used.
■ Inappropriate extinguishing agents: None to our knowledge. In the event of fire nearby, use the appropriate extinguishing agents.
■ Specific hazards:
● Rise in pressure. In the presence of air, an inflammable mixture may form under certain temperature and pressure conditions.
● Toxic and corrosive vapours may be released by the effect of the heat.
■ Special intervention methods: Cool the volumes exposed to heat with water spray.
■ Protection of the firemen:
● Full self-contained breathing apparatus.
● Complete body protection.
1.5.6 In the event of accidental spillage
■ Individual precautions:
● Avoid contact with the skin and eyes.
● Do not intervene without appropriate protective equipment.
● Do not inhale the vapours.
● Evacuate the hazardous area.
● Stop the leakage.
● Eradicate all sources of ignition.
● Ventilate the spillage area mechanically (risk of asphyxia).
■ Cleaning / Decontamination: Allow residual product to evaporate.
1.5.7 Handling
■ Technical measures: Ventilation.
■ Precautions to be taken:
● No smoking.
● Prevent the build-up of electrostatic charges.
● Work in a well ventilated place.
1 Safety Instructions
Page 12
7638216-02 - 1906201512 KALIKO SPLIT
1 Safety Instructions
1.5.8 Personal protection
■ Respiratory protection:
● If insufficient ventilation: AX type cartridge mask
● In confined spaces: Full self-contained breathing apparatus.
■ Hand protection: Protective gloves in leather or nitrile rubber.
■ Eye protection: Safety glasses with side protection.
■ Skin protection: Clothing made mostly of cotton.
■ Industrial hygiene: Do not drink, eat or smoke in the work place.
1.5.9 Regulations
■ EC Regulation 842/2006: Fluorinated greenhouse gases under the Kyoto Protocol.
■ Classified installations No. 1185
1.6 Internet site
Note
The user and installation manuals are also available on our internet site.
Page 13
137638216-02 - 19062015 KALIKO SPLIT
2 About this manual
2 About this manual
2.1 General
This manual is intended for the installer of a TWH Split FS 200 E or TWH Split FS 270 E thermodynamic water heater, incorporating an SFS 200 E or SFS 270 E domestic hot water tank and an outdoor unit with SODU 2 M display.
2.2 Documentation available
● Installation and Service Manual
● User Guide
2.3 Symbols used
2.3.1 Symbols used in the manual
Danger
Risk of dangerous situations that may result in serious personal injury.
Danger of electric shock
Risk of electric shock.
Warning
Risk of dangerous situations that may result in minor personal injury.
Caution
Risk of material damage.
Note
Please note: important information.
See
Reference to other manuals or pages in this manual.
2.3.2 Symbols used on the appliance
Fig.1 Symbols used on the appliance
1 Alternating current. 2 Protective earthing. 3 Before installing and commissioning the appliance, carefully read the
instruction manuals provided.
4 Dispose of used products in an appropriate recovery and recycling
structure.
5 Caution: danger of electric shock, live parts.
Disconnect the mains power prior to carrying out any work.
6 Electrical back-up. 7 CE Marking: equipment conforming to European legislation. 8 NF Marking: equipment that respects French safety and performance
criteria.
9 Protection rating.
NIE-A-003
1
2
3
4
5
6
7
8
9
IPX1B
Page 14
7638216-02 - 1906201514 KALIKO SPLIT
3 Technical specifications
3.1 Homologations
3.1.1 Certifications
■ NF certification
Appliances concerned: KALIKO SPLIT (TWH Split FS 200 E or TWH Split FS 270 E) Specifications LCIE 103-15/B (July 2011) for NF Electricity Performance Marking This product complies with the requirements of the following NF Standards on Electricity:
● EN 60335-1:2002 +A1:2004 +A11:2004 +A12:2006 +A2:2006 +A13:2008 +A14:2010
● EN 60335-2-21:2003 +A1:2005 +A2:2008
● EN 60335-2-40:2003 +A11:2004 +A12:2005 +A1:2006 +A2:2009
● EN 62233:2008
● EN 16147:2011
■ Electrical Conformity / CE Marking
This product complies with the requirements of the following European Directives and Standards:
- 2006/95/EC Low Voltage Directive Relevant Standard: EN 60.335.1.
- 2004/108/EC Electromagnetic Compatibility Directive
3.1.2 Directive 97/23/EC
This product complies with the requirements of European Directive 97 / 23 / EC, Article 3, Paragraph 3, on pressurised appliances.
3.1.3 Test before leaving the factory
Before leaving the factory, each appliance is tested on the following elements:
- Water tightness.
- Air tightness.
- Electrical safety.
3 Technical specifications
Page 15
157638216-02 - 19062015 KALIKO SPLIT
3.2 Technical data
3.2.1 Characteristics of the appliance
Model Unit TWH Split FS 200 E TWH Split FS 270 E
Daily electricity consumption (Q
elec
) kWh 3.532 5.576
Declared load profile L XL
Sound power level at 1 m indoors (L
WA
)
(4)
dB(A) <17 <17
Daily fuel consumption (Q
fuel
) kWh 0 0
Emissions of nitrogen oxides (NO
X
) mg/kWh 0 0
Weekly fuel consumption with smart controls (Q
fuel, week,smart
)
kWh - -
Weekly electricity consumption with smart controls (Q
elec, week,smart
) kWh - -
Weekly fuel consumption without smart controls (Q
fuel, week,smart
) kWh - -
Weekly electricity consumption without smart controls (Q
elec, week,smart
) kWh - -
Storage volume (V) I 215 270
Mixed water at 40°C (V40) I 299 373
Sound power level, outdoors (L
WA
)
(4)
dB(A) 59 59
Output (outdoor unit) air temperature = 7°C W 1750 1750
Absorbed electrical power (outdoor unit) W 900 900
Heating time (10-54°C)
(1)
hours 5.5 7.1
COP in accordance with the EN16147 standard
(1)
3.30 3.42
Pes (Output)
(1) (3)
W 26.5 28.5
Air flow rate – maximum m
3
/h 1300 1300
Electrical resistor output W 2400 2400
Operating pressure MPa (bar) 1.0 (10) 1.0 (10)
Power supply voltage V 230 230
Circuit breaker A 16 16
Refrigerant fluid R134a kg 1.60 1.60
Length of the refrigeration connection (minimum / maximum) m 2 / 20 2 / 20
Maximum difference in height on the refrigeration connection m 10 10
Weight of the domestic hot water tank (empty) kg 70 82
Protection of the domestic hot water tank IP X1B X1B
Weight of the outdoor unit kg 33 33
Protection of the outdoor unit IP 24 24
Limit operating temperatures of the outdoor unit °C -15 / 42 -15 / 42
Settings range for the domestic hot water set point °C 38/75 38/75
(1) Value obtained with an air temperature of 7°C and a water temperature of 10°C, according to LCIE Specifications No. 103­15/B:2011 based on the NF EN 16147 standard, with a 5-m long refrigeration connection with 0 m difference in height. (2) Equivalent hot water volume at 40°C. (3) Electrical power consumed with no hot water use. (4) Value obtained at 20°C air on average during heating from 10°C to 55°C.
3 Technical specifications
Page 16
7638216-02 - 1906201516 KALIKO SPLIT
3.2.2 Heating time of the thermodynamic water heater according to air temperature
Fig.2 Heating time TWH Split FS 200 E
■ Scenario for complete heating cycles on the thermodynamic water
heater for a cold water temperature of 10°C
Y
-15 -5
0
1
2
3
4
5
6
7
8
9
10
11
12
13
15 25 35
5
B
A
X
A Heating time for a set point of 40 °C B Heating time for a set point of 55 °C X Air temperature (°C) Y Heating time (hours)
Fig.3 Heating time TWH Split FS 270 E
Y
-15 -5
0
1
2
3
4
5
6
7
8
9
10
11
12
13
15 25 35
5
B
A
Y
-15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
5152535
-5
B
A
X
X
3.2.3 Operation and limits of the thermodynamic water heater
Fig.4 Maximum temperature in
thermodynamic mode
The graph opposite shows the maximum temperature at which the outdoor unit can heat up the domestic hot water tank according to air temperature.
40° 35°
-15 -10
-7 23
24
237
X
55°
60°
62°
65°
Y
X Air temperature (°C) Y Domestic hot water temperature (°C).
Note
For a set point in excess of the limits of the thermodynamic mode, the surplus will be handled by the immersion heater in the domestic hot water tank. In order not to impair the life span and maintain the reliability of the components, the outdoor unit has a limit on its
operating temperature (air temperature -15°C/+42°C) and domestic hot water production (see fig.4).
3 Technical specifications
Page 17
177638216-02 - 19062015 KALIKO SPLIT
4 Description of the product
4.1 General description
The thermodynamic water heaters in the KALIKO SPLIT range
have the
following specifications:
● Floor-standing thermodynamic storage water heater
● Heat pump extracting energy from the outside air
● Display with timer program
● 2.4 kW steatite immersion heater
● Glass-lined tank protected by magnesium anode
● Very thick insulation (0% CFCs).
The domestic hot water tank can be heated by:
● The outdoor unit (Cf fig. 4).
● The immersion heater (electrical back-up - AUTO Mode and E-heat Mode) (up to 70°C).
4.2 Operating principle
The thermodynamic water heater uses the outside air to produce domestic hot water. The refrigerant circuit is a closed circuit in which the R-134a refrigerant plays the role of an energy carrier. The heat from the intake air is transferred to the refrigerant in the finned heat exchanger at a low evaporation temperature. The refrigerant is drawn in in vapour form by a compressor, which raises it to a higher pressure and temperature and sends it to the condenser. In the condenser, the heat extracted in the evaporator and some of the energy absorbed by the compressor are released into the water. The refrigerant is depressurised in the expansion valve and then cooled. The refrigerant fluid can again extract the heat contained in the intake air from the evaporator.
Fig.5 Schematic diagram
1
6
7 4 5 3
8
2
1 Domestic hot water tank 2 Outside unit 3 Condenser 4 Evaporator 5 Compressor 6 Expansion valve 7 Fan 8 Air flow
4 Description of the product
Page 18
7638216-02 - 1906201518 KALIKO SPLIT
4.3 Main components
4.3.1 Domestic hot water tank
Fig.6 Description of the components
5
8
9
11
13
10
12
7
1
2
3
4
14
6
15
16
17
1 Top cover 2 Top insulation 3 Sensor cable duct 4 230-V sensor cable duct 5 Condenser tube 6 Domestic hot water outlet 7 Magnesium anode 8 Sensor tube 9 Temperature sensor 10 Steatite immersion heater 11 Safety thermostat 12 Condenser 13 Domestic cold water inlet 14 1/4" refrigeration connection 15 Sensor cable clamp 16 3/8" refrigeration connection 17 230-V cable clamp
Note
Do not place anything on top of the domestic hot water tank.
4 Description of the product
Page 19
197638216-02 - 19062015 KALIKO SPLIT
4.3.2 Outdoor unit
Fig.7 Description of the components
4
3
2
1
12
15
13
14
16
17
11
8
9
10
7
5 6
1 Evaporator 2 Fan 3 Compressor 4 Compressor outlet temperature sensor 5 Display connection terminal block 6 Temperature sensor connector 7 Three-way valve 8 2-way valve 9 Evaporator temperature sensor
10 Filter-drier 11 Outside temperature sensor 12 Electronic expansion valve 13 High pressure pressure switch 14 4-way valve 15 Electrical connection terminal block 16 Air suction temperature sensor 17 Electrical control unit
4 Description of the product
Page 20
7638216-02 - 1906201520 KALIKO SPLIT
4.4 Description of the display
4.4.1 Description of the control keys
Fig.8 Description of the keys
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
3
2
4
1
56
Electrical
Heating
Timer /
Clock
Enter
1 MODE key (choice between holiday mode and in residence) 2 Operating indicator (In Residence: green light / Holiday: light off) 3 Browse keys 4 Forced mode activation 5 Programming 6 Confirm key
4.4.2 Description of the display
Fig.9 Description of the display
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
4
2
1
5
6
3
Enter
Electrical
Heating
Timer /
Clock
1 Temperature set point / domestic hot water temperature / error code 2 Error indicator 3 Operating status indicator for the electrical back-up 4 Compressor operation indicator 5 Time display (hour:minutes) 6 Burner operating hours setting
4 Description of the product
Page 21
217638216-02 - 19062015 KALIKO SPLIT
5 Using the appliance
5 Using the appliance
5.1 Using the control panel
5.1.1 First time commissioning
Caution
Only a qualified professional may carry out first time commissioning.
1 Connecting the system to the mains
Fig.10 Start-up
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Electrical
Heating
Enter
Timer /
Clock
Starting up the thermodynamic water heater: 2 Press the MODE key (in residence). The operating indicator light
comes on.
Note
Pressing the MODE key a second time puts the appliance in holiday mode. The operating indicator light goes off.
Fig.11 Check
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Enter
Electrical
Heating
Timer /
Clock
3 Check that no error codes or messages are shown on the display.
The domestic hot water set point temperature is set to 50°C in the
factory. The compressor starts up after 3 minutes if domestic hot water production is required.
Note
To speed up the heating process, select the operating mode: electrical back-ups § 5.1.5 The appliance will automatically return to normal operating mode once the temperature set point has been reached.
Page 22
7638216-02 - 1906201522 KALIKO SPLIT
5 Using the appliance
Fig.12 Timer/Clock
5.1.2 Setting the time
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Timer /
Clock
Enter
Electrical
Heating
Set the time: 1 Press Timer/Clock
The display “hh” on the “hh : mm” display starts flashing, meaning that
the hour can be set.
Fig.13 Setting the time
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Enter
Electrical
Heating
Timer /
Clock
2 Press the up/down arrows to go forwards or back.
Fig.14 Minutes setting
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Timer /
Clock
Enter
Electrical
Heating
3 Press Timer/Clock
The minutes display begins to flash. 4 Proceed in the same way to set the minutes.
Fig.15 Confirmation
Electrical
Heating
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Timer /
Clock
Enter
5 Press Enter to confirm.
Page 23
237638216-02 - 19062015 KALIKO SPLIT
Fig.16 Starting the heating process
5.1.3 Setting the operating ranges
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Enter
Electrical
Heating
Timer /
Clock
Two operating ranges are available: Timer 1 and Timer 2. Both operating ranges are set in a similar manner.
For each operating range, set a start time and an end time. 1 Press Timer/Clock three times to select Timer 1 - On. 2 The display “hh” on the “hh : mm” display starts flashing, meaning that
the start time for the heating process is ready to be set.
Fig.17 Setting the start time
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Enter
Electrical
Heating
Timer /
Clock
3 Press the up/down arrows to go forwards or back.
Fig.18 Minutes setting
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Enter
Electrical
Heating
Timer /
Clock
4 Press Timer/Clock 5 The minutes display starts flashing. 6 Set the minutes using the up/down arrows to go forwards or back.
Fig.19 Confirmation
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Electrical
Heating
Enter
Timer /
Clock
7 Press Timer/Clock to confirm.
The start time of the heating process is confirmed.
5 Using the appliance
Page 24
7638216-02 - 1906201524 KALIKO SPLIT
Fig.20 End of the heating process
Timer 1
On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
NIE-A-082
Enter
Electrical
Heating
Timer /
Clock
8 The display “hh” on the “hh : mm” display starts flashing, meaning that
the end time for the heating process is ready to be set.
Fig.21 Setting the end time
Timer 1
On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Enter
Electrical
Heating
Timer /
Clock
9 Press the up/down arrows to go forwards or back.
Fig.22 Minutes setting
Timer 1
On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Enter
Electrical
Heating
Timer /
Clock
10 Press the Timer/Clock key. 11 The minutes display starts flashing. 12 Set the minutes using the up/down arrows to go forwards or back.
Fig.23 Confirmation
Timer 1
On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Electrical
Heating
Timer /
Clock
Enter
13 Press the Enter key to confirm or press the Timer/Clock key again to
set the second operating range.
The end time of the heating process is confirmed.
Note
To reset the timer program to zero, hold down the Timer/Clock key for 3 seconds.
5 Using the appliance
Page 25
257638216-02 - 19062015 KALIKO SPLIT
Fig.24 Setting the set point
5.1.4 Setting domestic hot water set point
Set Temp
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Electrical
Heating
Timer /
Clock
Error
Enter
The domestic hot water set point is set with the up arrow and the down arrow keys. 1 Press the up arrow key to increase the set point or
press the down arrow key to reduce it. The set point
value flashes. 2 Confirm by pressing the Enter key.
■ Settings table for the domestic hot waterset point value according to the number of showers per day.
200-litre model
Number of showers Set point
3 50
4 50
5 50
6 55
7 60
8 65
9 70
270-litre model
Number of showers Set point
3 50
4 50
5 50
6 50
7 50
8 55
9 60
10 65
11 70
5 Using the appliance
Page 26
7638216-02 - 1906201526 KALIKO SPLIT
Fig.25 E-Heat mode
5.1.5 Electrical back-up
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
NIE-A-058
Electrical
Heating
Timer /
Clock
Enter
- Press the Electrical Heating key. The Electrical Heating icon flashes.
- Press the Enter key to confirm. Once the set point has been reached, the control system goes back to normal mode.
■ Presentation of
electrical back-up mode:
This mode is used to bring the thermodynamic water heater quickly up to temperature by simultaneously running the heat pump and the electrical back-up.
5.1.6 Recommissioning procedure after a power outage
1 Check that the thermodynamic water heater is running (green LED
on). Otherwise, press the MODE key.
2 Check the time setting on the display §5.1.2. 3 Check the programming of the the operating ranges §5.1.3.
5 Using the appliance
Page 27
277638216-02 - 19062015 KALIKO SPLIT
6 Switching off the appliance
6.1 Switching off the installation
Caution
Do not switch off the appliance so as not to delete the control parameters. Instead, press the MODE button on the display and deactivate the operating ranges (see §5.1.2) to put the thermodynamic water heater in holiday mode. It will thus be protected from frost.
6.2 Prolonged absence
In the event of prolonged absence, press the MODE button on the display and deactivate the operating ranges (see §5.1.2) to put the thermodynamic water heater in holiday mode. It will thus be protected from frost.
6 Switching off the appliance
Page 28
7638216-02 - 1906201528 KALIKO SPLIT
7 Maintenance
7.1 General
OFF
Caution
Installation and maintenance of the appliance must be done by a certified professional in accordance with prevailing statutory texts and codes of practice.
Caution
Before working on the appliance, ensure that it is switched off and safe.
Caution
Check the discharge from the compressor condenser.
Caution
Before carrying out any work on the refrigerant circuit, shut down the appliance and wait a few minutes. Certain items of equipment such as the compressor and the pipes can reach temperatures in excess of 100 °C and high pressures, which may cause serious injuries.
Note
When the appliance is switched off, the fan continues to run by inertia for approximately one minute.
Maintenance operations are important for the following reasons:
● To guarantee optimum performance
● To extend the life span of the equipment
● To provide an installation which offers the customer optimum comfort over time.
Caution
The control components must never come into contact with water. Before cleaning, cut the power to the appliance.
Caution
If it becomes necessary to disconnect the refrigerant connections, be sure to recover the refrigerant fluid.
7 Maintenance
Page 29
297638216-02 - 19062015 KALIKO SPLIT
8 Troubleshooting
8.1 Messages (Ex and Px type code)
Fig.26 Faults display
8.1.1 Messages on the display
Set Temp
Timer 1 On Off
Timer 2 On Off
Set Temp
Error
Electrical Heating
Heating
Electrical
Heating
Enter
Timer /
Clock
Error
In the event of disruption, the control panel displays a message and a corresponding code:
- The "spanner" pictogram appears
- The green warning light flashes
1 Make a note of the code displayed.
The code is important for the correct and rapid diagnosis of the type of error and for any technical assistance that may be needed.
2 Switch off and then switch the appliance back on.
The appliance starts up again autonomously when the reason for the disruption has been cleared.
3 If the code is displayed again, correct the problem by following the
instructions in the table below:
Code Description Check / Solution
E2
Communication error between the outdoor unit and the display
Contact the professional who handles maintenance of the appliance
E4
T5L water temperature sensor error Contact the professional who handles maintenance of the
E5
T3 evaporation temperature sensor error Contact the professional who handles maintenance of the
E6
T4 air temperature sensor error Contact the professional who handles maintenance of the
E9
Th suction temperature sensor error Contact the professional who handles maintenance of the
EA
Tp discharge temperature sensor error Contact the professional who handles maintenance of the
EP
Electrical differential error Contact the professional who handles maintenance of the
P1
High pressure error Contact the professional who handles maintenance of the
P2
Electrical overconsumption error on the compressor
Contact the professional who handles maintenance of the appliance
P4
Discharge temperature error: too high Contact the professional who handles maintenance of the
bA
Air temperature information outside the operating limits
The weather and/or installation conditions do not enable the heat pump to operate. Hot water is produced by the electrical back-up.
EF
Error on the main controller Contact the professional who handles maintenance of the
appliance
db
Frost protection running Contact the professional who handles maintenance of the
appliance
Note
Press the Down Arrow key and Enter simultaneously for 3 seconds to clear the errors.
8 Troubleshooting
Page 30
7638216-02 - 1906201530 KALIKO SPLIT
9 Scrapping / Recycling
9.1 General
Caution
This appliance bears the recycling symbol pursuant to European Directive 2002/96/EC on Waste from Electrical and Electronic Equipment (WEEE). In correctly disposing of this appliance, you are helping to prevent any consequences harmful to the environment or human health.
Note
The symbol found on this appliance and in the documentation that accompanies it indicates that this product may under no circumstances be treated as household waste. It must therefore be brought to a waste collection centre responsible for recycling electrical and electronic equipment.
As regards scrapping, abide by the standards on the elimination of waste in force in the country of installation.
If electrical appliances are discarded on a rubbish tip, hazardous substances may leak into the groundwater, enter the food chain and have harmful consequences on health and well-being.
9 Scrapping
Page 31
317638216-02 - 19062015 KALIKO SPLIT
10 Appendices
10.1 Declaration of Conformity
The appliance complies with the standard type described in the EC declaration of conformity. It has been put into circulation in accordance with the requirements of European Directives.
The original of the declaration of compliance is available from the manufacturer.
10 Appendices
Page 32
7638216-02 - 1906201532 KALIKO SPLIT
10 Appendices
10.2 ErP information
10.2.1 Product data sheet: thermodynamic water heater
Brand name - Product name Unit TWH Split FS 200 E TWH Split FS 270 E
Declared load profile L XL
Water heating energy efficiency class under average weather conditions
A A
Water heating energy efficiency under average weather conditions
% 138 141
Annual energy consumption
kWh
(1)
GJ
(2)
743
0
119
0
Other draw-off profiles for which the water heater is appropriate and water heating energy efficiency and corresponding annual electricity consumption
(3)
Thermostat temperature setting
°C 55 54
Sound power level L
WA
indoors
(3)
dB(A) <17 <17
Operating capacity in off-peak hours
(3)
Smart control enabled
(4)
- -
Water heating energy efficiency under colder ­warmer weather conditions
% 90-167 92-173
Annual energy consumption under colder - warmer weather conditions
kWh
(1)
GJ
(2)
1140-612
0
1813-970
0
Sound power level L
WA
outdoors dB(A) 59 59
(1) Electricity. (2) Fuel. (3) If applicable. (4) When the stated smart value is "1", the information on water heating energy efficiency and annual electricity and fuel consumption, as applicable, refers only to the situation in which smart control is enabled.
See
For specific precautions about assembly, installation and maintenance: Refer to chapter 1 “Safety instructions”.
Page 33
337638216-02 - 19062015 KALIKO SPLIT
Notes
Page 34
7638216-02 - 1906201534 KALIKO SPLIT
Notes
Page 35
357638216-02 - 19062015 KALIKO SPLIT
Notes
Page 36
DE DIETRICH THERMIQUE 57, ruedelaGareF- 67580 MERTZWILLER-BP 30
7638216- 001- 02
7638216 v02 - 19062015
Loading...