De dietrich DHD506XU1, DHD506XU2, DHD509XU2, DHD509XU1 User Manual

User's guide - Trapezoid hood
EN
Introduction
Dear Customer,
Thank you for choosing the De Dietrich hood. Our design staff have produced a new generation of kitchen equipment, to make everyday cooking a pleasure. The modern, attractive design of your new De Dietrich hood will blend smoothly into your kitchen installation, providing an optimum combination of easy use and performance. The De Dietrich range also includes a huge choice of fitted cooking hobs, ovens, dish-washers and refrigerators, that will match your new De Dietrich hood. A specialist in the world of cooking, De Dietrich works hard to contribute to your culinary success, and your cooking pleasure, offering ever more effective products, which are easy to use, environmentally friendly, attractive and reliable.
The De Dietrich name.
Safety instructions
- You should never "flambé" dishes under the hood or operate gas rings under the hood without cooking utensils being placed on them (the flames sucked up into the hood can damage the appliance).
- When frying food under the appliance, a careful watch must be kept on this at all times.
- Repairs must only be carried out by an approved specialist.
- You should regularly clean the filter cartridge to avoid any risk of fire.
- The hood should never be used over a combustible fuel burning stove (wood, coal, etc).
These hoods have been designed for non-commercial use in private homes. With a view to constantly improving our products, we reserve the right to modify their technical, functional or aesthetic characteristics, making any changes to their features considered necessary or desirable in view of technical progress. These hoods are designed exclusively for cooking foodstuffs and drinks. These products do not contain any asbestos based components.
Throughout this manual,
indicates safety recommendations,
indicates advice to help you make the best use of your oven
Installing your hood?
If you possess an outlet to the exterior: fig. 4 Your hood can be connected to this using a flue (Ø 125 or 150 mm, enamelled, made from aluminium, flexible or made from a non-flammable material). If you flue is below 125 mm in diameter, you must obligatorily use the “recycling” mode.
If y
ou do not possess an outlet to the exterior: fig. 5 All of our appliances can be used in recycling mode. In this case, you should add an active carbon filter which will keep in odours.
The controls on your hood Fig.1
In the case of a kitchen heated by a device connected to a chimney (for example a stove) the "recycling" version of the hood should be installed. Do not
use the hood without metal filters. Suitable ventilation should be ensured for the room when the suction hood is used at the same time as appliances using gas or another combustible fuel.
3-speed model
Motor off
Slow speed
Medium speed
Fast speed
Light off
Light on
The hood must be installed in conformity with the applicable regulations concerning the ventilation of premises. In France, these regulations are
detailed in DTU 61.1 from the CSTB. In particular, the evacuated air must not be channelled into a duct used to evacuate fumes from appliances using gas or other combustible fuels. Disused ducts may only be used after approval from a competent specialist. The minimum distance between the cooking surface and the lowest part of the hood must be 70 cm. If the instructions for the hob installed under the hood specify a distance of more than 70 cm, this requirement must be respected.
- Draw a horizontal line 70 cm minimum from the cooktop (fig. 2).
- Draw a vertical line on the wall running from the ceiling to the lower edge of the hood aligned with the cooktop (fig. 2).
- Place the mounting hole template against the wall (fig. 2).
- Drill the 6 holes. Insert the 6 wall plugs.
- Screw up the top two screws of the hood, but not completely - allow them to protrude by 5 mm (fig. 3).
- Remove the metal filter.
- Attach the suction hood to the two screws (fig. 4).
Assembling your hood
Connecting up your hood
This appliance is delivered with a H 05 VVF power cable with 2 conductors of 0.75 mm² (neutral, live). This must be connected to the
220-240 V single phase mains network via a CEI 60083 standard plug which must remain accessible following installation. We will not be liable in the event of an accident arising following incorrect installation. The fuse for your installation must be 10 or 16A. If the power cable is damaged, call the after sales service department in order to avoid danger.
Adjust the level of your hood before fully tightening up all four screws.
Assembling the chimney
Hood to be used with external evacuation: fig. 5 and 9
- Attach the metal chimney bracket to the wall, also placing this against the ceiling (fig. 7).
- In the case of a flue with a diameter of 125 mm, use the adapter supplied (fig.9).
If your exterior duct is below 125 mm, you must obligatorily connect your hood in recycling mode.
- Prepare your telescopic chimney, taking care to block off the vents (fig. 9). Fit the chimneys into one another as far as they will go.
- Fit the upper part to the metal bracket (fig. 9).
- Adjust the length of the telescopic chimney by bringing down the lower part and fitting it to the top of the hood (fig. 9).
Hood to be used in "recycling" mode: fig. 6 and 10
- Attach the metal chimney bracket against the wall, also placing this against the ceiling. Take care to centre the deflector vis-à-vis the vertical line drawn on the wall (fig. 7).
- Place and screw the deflector plate to the chimney where the vents are located (fig. 8).
- Prepare your chimney, taking care to block off the vents so that they are visible (fig. 9).
- Attach the upper part to the metal chimney bracket.
- Adjust the length of the telescopic chimney by bringing down the lower part and fitting it into the top of the hood.
To ensure optimal use of your device, we advise that you connect a flue with a diameter of 150 mm (not supplied). Limit the number of angles and bends as far as possible, and keep the length of the flue to a minimum. In the event that the hood will be functioning using exterior evacuation, you should ensure a sufficient inlet of fresh air to avoid a pressure deficiency in the room.
Changing the lamp?
1. Remove metal filters (fig. 11).
2. Unscrew then change the E14-40W bulb (fig. 12).
3. Replace the metal filters.
Before carrying out any work, the power supply to the hood must be turned
off, either by unplugging it or by using the circuit breaker switch.
Dismantling the filter cartridge
(fig. 11)
Assembling the carbon filter
(fig. 13)
1. Remove the cartridges.
2. Place the carbon filter on the cartridge, on the inner side of the hood.
3. Fit the 2 fastener clips.
4. Repeat this operation on all of the cartridges.
Cleaning your hood?
The power supply to the hood must be turned off either by removing the plug
or by using the circuit breaker switch before you remove the metal filters.
After cleaning, the metal filters must be refitted in conformity with the
instructions.
MAINTENANCE
WHY?
HOW ?
VITAL EVERY MONTH
VITAL EVERY YEAR
This filter traps fatty vapours and dust. This
component plays an important part in
ensuring the effectiveness of your hood.
This filter traps odours and must be
changed at least once a year
depending on your level of use.
Use a commercial household cleaning product
then rinse abundantly and dry. This cleaning can
be carried out in your dishwasher in the vertical
position (ensure that the cartridge never
comes into contact with dirty crockery or
silver tableware).
You should order these filters from
your dealer (quoting the reference
shown on the ID plate located
inside the hood) and note the date
the filter was changed.
FILTER CARTRIDGE
ACTIVATED CARBON FILTER
Never use metal scouring pads, abrasive products or excessively stiff brushes.
To clean the body and the lighting port, you should use only commercial household cleaning products
diluted in water and then rinse using clean water, drying with a soft cloth.
Remove the protective film before using the
filter cartridge for the first time.
For hoods installed in
"recycling" mode.
To avoid all risks of fire.
166.5
Fig. 1 Fig. 2
Fig. 5
Fig. 6
Fig. 4
Fig. 3
391 mm
833 mini (recyclage) - 1033 mm maxi
256 mm
482 mm
m
m
5
3
m
2
m
m
600 / 900 m
5mm
> 70 cm
2
1
=
=
150
=
Fig. 7 Fig. 8
Fig. 9
Fig. 13
Fig. 11
Fig. 12
Fig. 10
=
99635682 11/05
Loading...