DE DIETRICH CBI-II, CBB 15 E User Manual

Reverse combustion log-fired boiler
CBI-II / CBB 15 E
EN
User Guide
300019729-001-C
.
1 Used symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 Important recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.1 Ventilating the boiler room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.3 Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.1 Installing the heating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.3 Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
3.4 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4.1 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4.2 Subsequent start-ups by the final user (at least at the beginning of the heating season) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4.3 Ignition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.4 Adding more logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5 Cleaning and regular servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5.1 Cleaning the boiler (Every 3 to 7 days) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5.2 Maximum quantity of ashes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5.3 Cleaning the flue gas collector (Around 1 time per month). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
5.4 Cleaning the extractor fan* (Around 1 time per month) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.5 Checking the doors (Around 1 time per month) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6 Stopping the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
2
CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C
2. Important recommendations
Congratulations on your choice of a high quality product. We strongly advise you to read the following instructions in order to guarantee the optimal operation of your appliance. We are sure that it will be entirely to your satisfaction and will meet with all of your expectations.

1 Used symbols

Caution danger
Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment.
Specific information
Information must be kept in mind to maintain comfort.
Reference
Z
Refer to another manual or other pages in this instruction manual.

2 Important recommendations

For a proper operating of the boiler, follow carefully the
instructions.
Any intervention on the appliance and heating equipment
must be carried out by a qualified technician.
The manufacturer is not liable for any improper use of the
appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter).
Keep children away from the boiler.
Incorrect use or unauthorised modifications to the
installation or the equipment itself invalidate any right to claim.
Keep to the polarity shown on the terminals: phase (L),
neutral (N) and earth
In the event of a power cut:
- Do not open the boiler doors.
- Do not add any fuel.
Check regularly that the installation contains water and is
pressurised.
Keep the boiler doors closed during operation.
Open the boiler doors only during commissioning and
when adding fuel.
Do not burn unsuitable fuel.
4
.

2.1 Ventilating the boiler room

Position the air inlets in relation to the high ventilation vents in order that the air is refreshed throughout the boiler room.
The minimum cross-sections and the positions of the fresh air inlet and the air outlet must comply with prevailing regulations.
Do not obstruct the air inlets in the room (even partially).
Caution:
In order to avoid damage to the boiler, it is necessary to prevent the contamination of combustion air by chlorine and/or fluoride compounds, which are particularly corrosive. These compounds are present, for example, in aerosol sprays, paints, solvents, cleaning products, washing products, detergents, glues, snow clearing salts, etc. Therefore:
- Do not suck in air evacuated from premises using such products: hairdressing salons, dry cleaners, industrial premises (solvents), premises containing refrigeration systems (risk of refrigerant leakage), etc.
- Do not stock such products close to the boilers.
If the boiler and/or peripheral equipment are corroded by such chloride or fluoride compounds, the contractual guarantee cannot be applied.
16/06/2009 - 300019729-001-C CBI-II / CBB 15 E
3
2. Important recommendations

2.2 Maintenance

- The boiler must be serviced and fully cleaned and the flue gas conduit swept by a qualified professional at least 2 times per year.
- We recommend taking out a maintenance contract.
- The boiler must be cleaned every 3 to 7 days.
- Check the seal on the boiler doors 1 time per month.

2.3 Fuel

Use
- Broad-leaved hardwood (oak, beech, hornbeam, etc.)
- Broad-leaved softwood (birch, poplar, lime, etc.)
- Resinous wood (pine, fir, spruce, larch, etc.): To be used occasionally (2 to 3 loads maximum and follow with the same number of hardwood and softwood loads)
Characteristics of logs that can be used
- Dry wood, stored under cover (for at least 2 years), with a low humidity level (less than 20% of the gross mass)
- Logs with a maximum diameter of 150 mm
- Maximum length of the logs:
- Regularly check the level of water in the system and top up if required, taking care that cold water is not added suddenly into the boiler when it is hot. If this operation is repeated several times per season, locate the leak and repair it.
Do not drain the installation, except in cases of absolute
necessity. For example: Several months' absence with the risk of ice in the building.
Do not use
- Chipboard panels
- Coated, painted or treated wood
- Wood containing pieces of metal
- Wood not stored under cover for at least 12 months
- Any fuel other than wood
Model CBI-II 20 CBI-II 30 CBI-II 40 CBB 15 E
mm 330 530 530 330
- For improved combustion quality, prefer shorter logs (25 - 33 cm) split into cross-sections with a maximum diameter of 10 to 15 cm.
- For more regular combustion, better boiler autonomy and improved annual efficiency, arrange the logs in an orderly manner in the combustion chamber.
Calorific power and energy content of various types of wood
Broad-leaved softwood and
conifers
Type of wood
Gross humidity
(%)
Average weight of a
stere of wood
(kg/stere)
Calorific power
(kWh/kg)
Energy content
(kWh/stere)
Broad-leaved
hardwood
20 30 20 30
530 600 380 440
3.9 3.3 3.9 3.3
2070 1980 1480 1450
Equivalent in litres of
fuel oil
(l/stere)
Equivalent between storage volume requirements Fuel oil: 2000 l F 2m = 15 stere of logs F 15 m
210 200 150 145
3
(1 m x 1 m x 2 m)
3
(3 m x 2.5 m x 2 m)
Multiplied by 2 for storage over 2 years
(Drying of freshly cut wood)
4
CBI-II / CBB 15 E 16/06/2009 - 300019729-001-C

3 Description

3.1 Installing the heating

Depending on the heating installation, certain components can be suppressed or added. Get your fitter to explain your installation to you.
Description Operation
3. Description
CBI-II
Reverse combustion log-fired
boiler
CBB 15 E
Log-fired boiler with natural
draught
EA108
Wall module for elevating the
return temperature
ML9
Thermostatic module for elevating
the return temperature
Logs
Burns wood in complete safety and protects the environment. Removes the heat from the fumes given off by combustion and transfers it to the heating water.
Burns wood in complete safety and protects the environment. Removes the heat from the fumes given off by combustion and transfers it to the heating water.
Used to read the return temperature. Stays off if the return temperature is lower than 60°C.
Used to prevent the return of water colder than 60°C into the boiler.
The natural energy of wood is converted into heat by combustion in the Bioenergy boiler.
Buffer tank
PS / PSB
DC / QUADRO
Domestic hot water tank
LIGHT / DUO / TRIO
8962N094A
DIEMATIC VM
Regulation
Differential regulator Controls the domestic load pump.
Radiators or underfloor heating Transfers the heat from the heating water to the premises.
Used for storing hot water extracted from the biofuel boiler (max. 85°C). Compensates for any differences between heat production and needs. Solar use with DC / QUADRO
Maintains a reserve of domestic hot water for the household (e.g. shower) with an electric back-up for the summer. Solar use with LIGHT / DUO / TRIO
Optimally ensures the desired temperature on the premises and saves on fuel, whatever the outside temperature.
16/06/2009 - 300019729-001-C CBI-II / CBB 15 E
5