DE DIETRICH AGC 15, AGC 25, AGC 35 User Manual

Modulens
Gas fired floor-standing condensing boiler
AGC 10/15 AGC 15 AGC 25 AGC 35
EN
User Guide
300026080-001-03
Contents
1.1 Symbols used .......................................................4
1.1.1 Symbols used in the manual ...................................4
1.1.2 Symbols used on the equipment .............................4
1.2 Abbreviations ........................................................5
1.3 General ..................................................................5
1.3.1 Manufacturer’s liability .............................................5
1.3.2 Installer’s liability .....................................................6
1.3.3 User’s liability ..........................................................6
1.4 Certifications .........................................................6
2 Safety instructions and recommendations ..............................................7
2.1 Safety instructions ...............................................7
2.2 Recommendations ................................................8
3 Description ..................................................................................................9
3.1 Operating principle ...............................................9
3.1.1 Gas/air setting .........................................................9
3.1.2 Combustion .............................................................9
3.2 Main parts ............................................................10
3.3 Control panel .......................................................11
3.3.1 Description of the keys ..........................................11
3.3.2 Description of the display ......................................12
3.3.3 Browsing in the menus ..........................................15
4 Operating the appliance ..........................................................................16
4.1 Putting the appliance into operation ................16
4.2 Reading out measured values ...........................16
4.3 Changing the settings ........................................18
4.3.1 Setting the set point temperatures ........................18
4.3.2 Selecting the operating mode ...............................19
4.3.3 Forcing domestic hot water production .................20
4.3.4 Setting the contrast and lighting on the
display ...................................................................20
4.3.5 Setting the time and date ......................................21
4.3.6 Selecting a timer programme ................................21
4.3.7 Customising a timer programme ...........................22
1
03/12/2013 - 300026080-001-03
Contents
4.4 Installation shutdown .........................................24
4.5 Antifreeze protection ..........................................24
5 Checking and maintenance .....................................................................26
5.1 General instructions ...........................................26
5.2 Periodic checks ..................................................26
6 Troubleshooting .......................................................................................28
6.1 Anti-hunting ........................................................28
6.2 Messages (Code type Bxx or Mxx) ....................28
6.3 Faults (Code type Lxx or Dxx) ...........................30
7 Technical specifications ..........................................................................36
7.1 Technical specifications ....................................36
8 Energy savings .........................................................................................38
8.1 Energy-saving advice .........................................38
8.2 Recommendations ..............................................38
9 Warranty ....................................................................................................39
9.1 General ................................................................39
9.2 Warranty terms ...................................................39
2
03/12/2013 - 300026080-001-03
3
03/12/2013 - 300026080-001-03
D000241-C
AGC 10/15 AGC 15 AGC 25 AGC 35
1 Introduction
1.1 Symbols used
1. Introduction
1.1.1. Symbols used in the manual
In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, obviate hazards and guarantee correct operation of the appliance.
DANGER
Risk of a dangerous situation causing serious physical injury.
WARNING
Risk of a dangerous situation causing slight physical injury.
CAUTION
Risk of material damage.
Signals important information.
¼Signals a referral to other instructions or other pages in the instructions.
1.1.2. Symbols used on the equipment
4
~
Protective earthing
Alternating current
Before installing and commissioning the device, read carefully the instruction manuals provided.
Dispose of the used products in an appropriate recovery and recycling structure.
03/12/2013 - 300026080-001-03
This appliance must be connected to the protective earth.
4
1 2
M002628-A
1. Introduction
1.2 Abbreviations
AGC 10/15 AGC 15 AGC 25 AGC 35
Caution: danger, live parts. Disconnect the mains power prior to any operations.
4 3CE: Collective conduit for sealed boiler
4 DHW: Domestic hot water
4 Interscenario switch: Home automation switch that can be used
to centralise and control several scenarios
4 Hi: Lower heating value LHV (Nett)
4 Hs: Higher heating value HHV (Gross)
4 PPS: Polypropylene hardly inflammable
4 PCU: Primary Control Unit - PCB for managing burner operation
4 PSU: Parameter Storage Unit - Parameter storage for PCBs
PCU and SU
4 SCU: Secondary Control Unit - control panel PCB
4 SU: Safety Unit - Safety PCB
4 3WV: 3-way valve
4 HL: High Load - DHW tank with plate exchanger
4 SL: Standard Load - DHW tank with coil
4 SHL: Solar High Load - Solar DHW tank with plate exchanger
4 SSL: Solar Standard Load - Solar DHW tank with coil
1.3 General
1.3.1. Manufacturer’s liability
Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore
delivered with [ marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
4 Failure to abide by the instructions on using the appliance.
4 Faulty or insufficient maintenance of the appliance.
4 Failure to abide by the instructions on installing the appliance.
5
03/12/2013 - 300026080-001-03
AGC 10/15 AGC 15 AGC 25 AGC 35 1. Introduction
1.3.2. Installer’s liability
The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Carry out installation in compliance with the prevailing legislation
and standards.
4 Perform the initial start up and carry out any checks necessary.
4 Explain the installation to the user.
4 If a maintenance is necessary, warn the user of the obligation to
check the appliance and maintain it in good working order.
4 Give all the instruction manuals to the user.
1.3.3. User’s liability
To guarantee optimum operation of the appliance, the user must respect the following instructions:
1.4 Certifications
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Call on qualified professionals to carry out installation and initial
start up.
4 Get your installer to explain your installation to you.
4 Have the required checks and services done.
4 Keep the instruction manuals in good condition close to the
appliance.
This appliance is not intended to be used by persons (including children) whose physcial, sensory or mental capacity is impaired or persons with no experience or knowledge, unless they have the benefit, through the intermediary of a person responsible for their safety, of supervision or prior instructions regarding use of the appliance. Care should be taken to ensure that children do not play with the appliance.
To prevent hazardous situations from arising, if the mains lead is damaged it must be replaced by the original manufacturer, the manufacturer’s dealer or another suitably skilled person.
03/12/2013 - 300026080-001-03
CE identification no
NOx classification
Type of connection Chimney: B23, B
CE-0085CM0178
5 (EN 297 pr A3, EN 483)
Flue gas outlet: C C
93(x)
33
13(x)
, C
33(x)
, C
43(x)
, C53, C
83(x)
,
6
2. Safety instructions and recommendations AGC 10/15 AGC 15 AGC 25 AGC 35
2 Safety instructions and
recommendations
2.1 Safety instructions
DANGER
If you smell gas:
1. Do not use a naked flame, do not smoke, do not operate electrical contacts or switches ( doorbell, light, motor, lift, etc..).
2. Shut off the gas supply.
3. Open the windows.
4. Evacuate the premises.
5. Call your fitter.
DANGER
If you smell flue gases:
1. Switch the appliance off.
2. Open the windows.
3. Evacuate the premises.
4. Call your fitter.
WARNING
Depending on the settings of the appliance:
4 The temperature of the flue gas conduits may exceed
60°C.
4 The temperature of the radiators may reach 85°C.
4 The temperature of the domestic hot water may reach
65°C.
CAUTION
Do not neglect to service the appliance: 4 For completely safe and optimum operation, you
must have your boiler regularly serviced by an approved installer.
7
03/12/2013 - 300026080-001-03
AGC 10/15 AGC 15 AGC 25 AGC 35 2. Safety instructions and recommendations
2.2 Recommendations
WARNING
Only qualified professionals are authorised to work on the appliance and the installation.
4 Regularly check the water pressure in the installation (minimum
pressure 0.8 bar, recommended pressure between 0.08 and 1.5 bar).
4 Keep the appliance accessible at all times.
4 Never remove or cover labels and rating plates affixed to the
appliance. Labels and rating plates must be legible throughout the entire lifetime of the appliance.
4 The appliance should be on Summer or Antrifreeze mode rather
than switched off to guarantee the following functions:
- Anti blocking of pumps
- Antifreeze protection
03/12/2013 - 300026080-001-03
8
3. Description AGC 10/15 AGC 15 AGC 25 AGC 35
3 Description
3.1 Operating principle
3.1.1. Gas/air setting
Air is sucked in by the fan and the gas injected into the venturi attached to the fan inlet. The fan rotation speed modulates and adapts to thermal energy requirements thanks to the temperatures measured by the various sensors. The gas and air are mixed in the venturi, which enables operation at a constant ratio. The noise of the venturi is absorbed by a silencer attached to its inlet. The gas/air mixture is carried to the burner in the top of the exchanger, guided by the pre­mix channel.
3.1.2. Combustion
The burner heats the heating water circulating in the heat exchanger. At a return temperature lower than around 55°C, the flue gases cool down to a temperature lower than the dew point, thus causing the condensation of the water vapour contained in the flue gases in the lower section of the heat exchanger. The heat released during this condensation process (the latent heat or condensing heat) is also transferred to the heating water. The cooled combustion gases are evacuated via the combustion gas outlet flue. The condensation water is evacuated via a siphon.
9
03/12/2013 - 300026080-001-03
C003072-C
18
19
16
17
15
14
13
12
11
1234
10
9
5
6
7
8
AGC 10/15 AGC 15 AGC 25 AGC 35 3. Description
3.2 Main parts
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Flue gas discharge pipe
Flue gas measuring point
Heat exchanger
Ignition/ionization electrode
Box for the control PCBs
Control panel
Command module
Water pressure sensor
Circulation pump
Hydroblock
3-way valve
Safety valve
Casing
Expansion vessel
Combined venturi and gas valve unit
Fan
Air intake silencer
18
19
Mixer pipe
Automatic air vent
03/12/2013 - 300026080-001-03
10
A000866-A
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
A
B
C
D
E
F
(
'
3. Description AGC 10/15 AGC 15 AGC 25 AGC 35
3.3 Control panel
3.3.1. Description of the keys
A
B
C
D
E
F
Temperature setting key (heating, DHW, swimming pool)
Operating mode selection key
DHW override key
Key to access the parameters reserved for the installer
Keys on which the function varies as and when selections are made
Rotary setting button:
4 Turn the rotary button to scroll through the menus or
modify a value
4 Press the rotary button to access the selected menu
or confirm a value modification
11
03/12/2013 - 300026080-001-03
C002705-A
C002704-A
C002703-A
C002702-A
bar
r
STD
(
'
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002696-A
p
b
AUTO
x
c
r
j
L
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002701-B
p
b
AUTO
x
c
r
j
M
g
m
AGC 10/15 AGC 15 AGC 25 AGC 35 3. Description
3.3.2. Description of the display
Key functions
n
> ( ’
?
f
STD
b
Access to the various menus
Used to scroll through the menus
Used to scroll through the parameters
The symbol is displayed when help is available
Used to display the curve of the parameter selected
Reset of the time programmes
Selection of comfort mode or selection of the days to be programmed
v
Selection of reduced mode or deselection of the days to be programmed
j
ESC
Back to the previous level
Back to the previous level without saving the modifications made
t
Flame output level
n
Manual reset
The whole symbol flashes: The burner starts up but the flame is not yet present
Part of the symbol flashes: Output is increasing
Steady symbol: The required output has been reached
Part of the symbol flashes: Output is dropping
03/12/2013 - 300026080-001-03
12
L000200-A
L000201-A
L000198-A
L000199-A
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
L000197-A
p
b
AUTO
x
c
r
j
M
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002697-B
p
b
AUTO
x
c
r
j
M
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002698-B
p
b
AUTO
x
c
r
j
M
g
m
3. Description AGC 10/15 AGC 15 AGC 25 AGC 35
Solar (If connected)
n
u
The solar load pump is running
The top part of the tank is reheated to the tank set point
The entire tank is reheated to the tank set point
The entire tank is reheated to the solar tank set point
The tank is not loaded - Presence of the solar control system
Operating modes
n
p
Summer mode: The heating is off. Domestic hot water continues to be produced
b
WINTER mode: Heating and domestic hot water working
AUTO
x
m
g
m
Operation in automatic mode according to the timer programme
Comfort mode: The symbol is displayed when a DAY override (comfort) is activated
4 Flashing symbol: Temporary override
4 Steady symbol: Permanent override
Reduced mode: The symbol is displayed when a NIGHT override (reduced) is activated
4 Flashing symbol: Temporary override
4 Steady symbol: Permanent override
Holiday mode: The symbol is displayed when a HOLIDAY override (antifreeze) is activated
4 Flashing symbol: Holiday mode programmed
4 Steady symbol: Holiday mode active
Manual mode: The boiler operates with the displayed set point. All of the pumps operate. The 3-way valves are not controlled.
13
03/12/2013 - 300026080-001-03
Loading...