400RR
COD.
EN
OTHER CHARACTERISTICS
613300 18NET
1800 kg
• • •
NET230N •
- Self locking with limit switches
- Speed adjustment and slow down in opening and closing
- Motor control by encoder and obstacle detection
613301
18NET/M
1800 kg
• • •
NET230N •
- Self locking
-
Magnetic limit switches
- Speed adjustment and slow down in opening and closing
- Motor control by encoder and obstacle detection
COD.
EN
OTHER CHARACTERISTICS
613210 25RRT
2500 kg
• • •
400RR •
- Self locking with limit switches
- Anti-crushing safety device
- Speed adjustment and slow down in opening and closing
- Motor control by encoder and obstacle detection
- Anti-inertia braking device (version 25RRTF only)
613215
25RRTF
2500 kg
• • •
400RR •
613221
25RRT/M
2500 kg
• • •
400RR •
- Self locking
- Speed adjustment and slow down in opening and closing
- Motor control by encoder and obstacle detection
- Magnetic limit switches
NET230N
230V a.c. operators with control board, limit switches and encoder
400V a.c. operators with control board, limit switches and encoder
Automations for industrial sliding gates
GULLIVER
COD. OTHER CHARACTERISTICS
613220* 1503E 1500 kg
• •
212E
- Self locking with limit switches
- Electronic force adjustment
- Automatic working time learning
- Controlled input for external safety device
212E 230V a.c. operators with control board and limit switches
TECHNICAL INFO 25RRT - 25RRTF - 25RRT/M - 25RRT/IB 18NET - 18NET/M - 18NET/IB - 1503E
Motor power supply (V) 400 AC ± 10 % (50/60 Hz) 230 AC ± 10 % (50/60 Hz)
Maximum power absorption (W) 1200 560
Max thrust (N) 1650 875
Duty cycle (cycles/hours) 17 - with a 14 mt. gate 15 - with a 12 mt. gate
N. max cycles in 24h. 280 240
Built-in capacitor (μF) / 30
Operating temperature (°C) -20 ÷ 50 -20 ÷ 50
Motor thermal protection (°C) / 140
Speed (m/min) 10 10
Weight with packing (Kg) 30 30
Protection degree IP34 (IP44 with magnetic limit switch) IP34 (IP44 with magnetic limit switch)
IN COMPLIANCE
WITH STANDARDS
* In order to respect the limit of impact forces foreseen by EN 12453 and EN12445 , you must use the external safety devices in compliance with EN 12978.
All models have: foundation plate (to be cemented) included
All models have: foundation plate (to be cemented) included
34
Cod. 668010
Art. 127
Warning sign
Cod. 672580
Art. TR2
Remote control
Black version art. TR2N also
available (page 118)
EXAMPLE OF A TYPICAL INSTALLATION
ELECTRICAL DIAGRAM
A
4x1 mm² (230V) o 3x1,5 mm² (24V ) - 6 x 0,5 mm²
4x0,5 mm²
2 x 0,5 mm² - RG58
2x0,5 mm²
4x0,5 mm²
2x0,5 mm²
3x0,5 mm²
2x0,5 mm²
B
240
120
410
330
115
DIMENSIONS
2
35
SLIDING GATES
Cod. 662030
Art. 104LUX
Pair of adjustable (15°) surface
mounted photocells
3
Cod. 664000
Art. PILLY/60
Pair of aluminium columns for photocells,
height 55 cm.
4
Cod. 661062
Art. LED230AI
Led flashing light 230V with
built-in antenna 433Mhz
7
Cod. 171001
Art. 123
Mechanical safety rib, length 200 cm.
5
Cod. 663030
Art. 102LUX
Keyswitch with two contacts, flush
mounted. Supplied with 2 keys.
6
Cod. 126001
Art. 112
Galvanized steel rack
22 x 22 mm (per mt.)
2
1
4
5
3 3
3
4
3
6
7
Cod. 613300
Art. 18NET
Operator for industrial
sliding gates
1