DEA 224RR Instruction Manual

Operating instructions and warnings
224RR
Control board 24V for gate automation operating
Instructions and warnings
OVERVIEW ................................................................................................................................12
1 PRODUCT CONFORMITY .....................................................................................................12
2 WARNINGS..........................................................................................................................12
3 MODELS AND CONTENTS OF THE PACKAGE .......................................................................13
4 PRODUCT DESCRIPTION ......................................................................................................13
5 TECHNICAL DATA.................................................................................................................14
6 OPERATING CONDITIONS ...................................................................................................14
7 ASSEMBLY AND WIRING INSTRUCTIONS..............................................................................14
8 USE INSTRUCTIONS .............................................................................................................15
8.1 Visualization of inputs status .......................................................................................15
8.2 Setup and memorization of the motor stroke ...............................................................16
8.3 Built-in radio receiver..................................................................................................17
8.4 Personalization of working parameters ........................................................................18
8.5 Reset of default parameters (p.007).............................................................................18
8.6 Safety devices .............................................................................................................18
8.7 Messages shown on the display...................................................................................19
9 MAINTENANCE ....................................................................................................................20
10 PRODUCT DISPOSAL............................................................................................................20
11 COMPLETE CLOSING ASSEMBLY...........................................................................................20
ENGLISH
OVERVIEW
These instructions were prepared by the manufacturer and are an integral part of the product. The operations described are designed for adequately trained and qualified personnel and must be carefully read and kept for future reference.
1 PRODUCT CONFORMITY
The 224RR programmable control board bears the CE label. DEA SYSTEM guarantees the conformity of the product to European Directives 89/336/CE and subsequent amendments (concerning electroma­gnetic compatibility), 73/23/CE and subsequent amendments (low voltage electrical equipment)
2 WARNINGS
12
Read these warnings carefully. Failure to respect the following warnings may cause risk situations.
WARNING DEA System reminds all users that the selection, positioning and installation of all materials and devices which make up the complete automation system, must comply with the European Directives 98/37/CE (Machinery Directive), 89/336/CE and subsequent amendments (electromagnetic compati­bility), 73/23/CE and subsequent amendments (low voltage electrical equipment). In order to ensure a suitable level of safety, besides complying with local regulations, it is advisable to comply also with the above mentioned Directives in all extra European countries.
WARNING Using the product under unusual conditions not foreseen by the manufacturer may cause dangerous situations; this is the reason why all the conditions prescribed in these instructions must be followed.
A1
A2
WARNING Under no circumstance must the product be used in an explosive environment or surroun­dings that may prove corrosive and damage parts of the product.
R
A3
224 RR
Operating instructions and warnings
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Any installation, maintenance or repair operation on the whole system must be carried out exclusively by qualified personnel. All these operations must be performed only after disconnecting the power supply, and operating in strict compliance with the electrical standards and regulations in force in the nation of installation.
WARNING Install the control board according to the instructions given in “F3 Installation”. Drill only the holes foreseen by the manufacturer to allow for wires passage, and use the specified clamps. Failure to comply with these instructions may jeopardize the level of electrical safety.
WARNING During the motors stroke memorization, the control board detects automatically the presen­ce and type of photocells, safety devices and limit switches which are installed. It is therefore essential that during this phase the latter be properly connected and working.
WARNING Wrong assessment of impact forces may cause serious damage to people, animal and things. DEA System reminds all personnel that the installer must ascertain that these impact forces, measured according to EN 12245 prescriptions, are actually below the limits indicated by EN12453 regulation.
WARNING Any external safety device installed in order to conform to the limits set for impact forces must comply with EN12978.
A4
A5
A6
A7
A8
A9
WARNING Using spare parts not indicated by DEA System and/or incorrect re-assembly may endanger people, animals and property, and may also cause malfunctioning of the product: always use parts provided by DEA System and follow assembly instructions.
A10
WARNING Disposal of packaging materials (such as plastic, card board, etc.) must be done according to regulations in force locally. Do not leave plastic bags and polystyrene within the reach of children
A11
WARNING Dumping batteries in the ordinary litterbin or leaving them just anywhere is extremely dan­gerous for the environment. Always use the differentiated waste disposal bins and comply with local re­gulations in force.
A12
3 MODELS AND CONTENTS OF THE PACKAGE
The control board 224RR is available also in the 224RR/B model complete with backup batteries in case of power failure.
4 PRODUCT DESCRIPTION
224RR control board has been designed for the automation of swing gates operated by 24Vdc motors. It is extremely versatile, easy to install and fully complies with European regulations concerning electro­magnetic compatibility and electric safety
Main features of the product:
1. setting all parameters by 3 keys and a 4-digit LCD display;
2. possibility of fine tuning of motor speed both during its complete stroke and during the last phase of it
(slow-down). It keeps motor torque even at very low speed;
3. possibility to set at will the slow-down duration of each of the two motors separately;
4. Internal anti-crash safety device whose sensitivity can be adjusted (according to a 70-level scale) se-
parately for the two motors and in both operating directions;
5. inputs to connect both normal and powered external safety devices (mechanical ribs or photo-
cell barriers), with the possibility to run a self-test before each operation. Controlled photocells;
13
224 RR
R
Operating instructions and warnings
6. built-in 433,92MHz radio receiver for both HCS and HT12E coding offering the possibility to search
and delete each transmitter separately.
WARNING DEA System reminds all users that the selection, positioning and installation of all materials and devices which make up the complete automation system, must comply with the European Directives 98/37/CE (Machinery Directive), 89/336/CE and subsequent amendments (electromagnetic compati­bility), 73/23/CE and subsequent amendments (low voltage electrical equipment). In order to ensure a suitable level of safety, besides complying with local regulations, it is advisable to comply also with the above mentioned Directives in all extra European countries.
5 TECHNICAL DATA
Power supply ....................................................230Vac +/- 10% 50Hz
Flashing light output .........................................24Vdc max 15W art. Lumy 24S
Auxiliary power supply output (+24VAUX) ..........24Vdc max 200mA
Safety devices power supply output (+24VSIC) ...24Vdc max 200mA
Electric lock output ............................................max 1 electric lock art. 110
LC/SCA contact capacity ...................................max 5A
Max motor capacity ..........................................2 X 70Wmax
Protection level .................................................IP54
Fuse F1 ............................................................2A 250V retarded
Fuse F2 ............................................................20A 250V retarded
Radio receiver frequency ...................................433,92 MHz rolling code / dipswitch coding
Max. number of transmitter controlled................100
A1
6 OPERATING CONDITIONS
224RR control board is designed for the automation of swing gates operated by 24 Vdc motors.
This control board has been designed and tested for operation under “normal” conditions for both residential and industrial use. The level of protection against dust and water and other data are illustrated in “5 Technical Data”.
WARNING Using the product under unusual conditions not foreseen by the manufacturer may cause dangerous situations; this is the reason why all the conditions prescribed in these instructions must be followed.
WARNING Under no circumstance must the product be used in an explosive environment or surroun­dings that may prove corrosive and damage parts of the product.
7 ASSEMBLY AND WIRING INSTRUCTIONS
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Any installation, maintenance or repair operation on the whole system must be carried out
14
exclusively by qualified personnel. All these operations must be performed only after disconnecting the power supply, and operating in strict compliance with the electrical standards and regulations in force in the nation of installation.
WARNING Install the control board according to the instructions given in “F3 Installation”. Drill only the holes foreseen by the manufacturer to allow for wires passage, and use the specified clamps. Failure to comply with these instructions may jeopardise the level of electrical safety.
Connect to the power supply 230 Vac ± 10% 50 Hz through a multi pole switch or a different device that can ensure multi pole disconnection from the power supply, with a contact opening of 3 mm. Use a cable with a minimum section of 3 x 1,5 mm² (e.g. a H07RN-F type).
Make all connections to the terminal board and remember to short-circuit, whenever necessary, all unused inputs. (See table 1 terminal board connection and Fig. 1 basic and complete wiring diagram)
A2
A3
A4
A5
A6
R
224 RR
Operating instructions and warnings
Table 1 Terminal board connection
1-2
LC/SCA
3-4
5-6
7-8
9-10
ELETTR
LAMP
M2
M1
11
SIC1
12
SIC2
13
FOTOC
Free contact max. capacity 5 A : this contact can be used to control an open gate warning light (P27=0) or a courtesy lamp (P270)
Electric lock output art. 110 12Vac 15VA
Flashing light output 24Vdc max 15W art. Lumy 24S (the intermittent output does not demand the use of a flashing light card)
Motor 2 output 24Vdc max 70W
Motor 1 output 24Vdc max 70W
N.C. leaf nr. 1 safety device input. In case of activation it reverses the movement (P18=0) or it stops (P18=1). If unused, short circuit to the terminal n°16
N.C. leaf nr. 2 safety device input. In case of activation it reverses the movement (P18=0) or it stops (P18=1). If unused, short circuit to the terminal n°16
N.C. Photocell input. In case of activation it reverses the movement only while closing (P26=0) or it reverses the movement while closing and stops while opening (P26=1). If unused, short circuit to the terminal n°16
14
+24VSIC
+24Vdc power supply output for controlled safety devices. To be used as power supply of photocell transmitters (in all cases) and of safety devices when testing these latter before each operation
15
+24VAUX
+24Vdc power supply output for auxiliary circuits and uncontrolled safety devices. To be used as power supply of any auxiliary devices, photocell receivers (in all cases), and
of safety devices when testing these latter before each operation 16 17 N.C. motor nr. 2 closing limit switch input. If unused, it may remain disconnected 18 19 20 21
COM Common safety devices
FCC2
FCC1 N.C. motor nr. 1 closing limit switch input. If unused, it may remain disconnected FCA2 N.C. motor nr. 2 opening limit switch input. If unused, it may remain disconnected FCA1 N.C. motor nr. 1 opening limit switch input. If unused, it may remain disconnected START N.O. open input. If activated, it opens or closes both motors. It can work in “reversal”
mode (P25=0) or “step-by-step” mode (P25=1) 22
PEDON N.O. pedestrian opening input. If activated, it opens motor nr. 1 only.
23
STOP N.O. stop input. If activated, it stops the movement of both motors during any opera-
tion 24
25 26 27-28 29-30
COM Common inputs
Aerial signal input
Aerial ground input
24VBatt 24Vdc battery power supply input (Follow carefully polarity indications)
24Vac 24Vac transformer power supply input
15
8 USE INSTRUCTIONS
After making all connections to the terminal board, remember to short-circuit, whenever needed, any unused input (see “connection to the control board”) and power the card: on the display you will read for a few seconds “rES-” followed by the symbol “----” which stands for gate closed.
8.1 Visualisation of inputs status
Press on the “OK” key to check that all inputs have been properly connected.
224 RR
R
Loading...
+ 7 hidden pages