dCS 900E / 902E User Manual Manual for Software Versions 1.3x to 1.5x
dCS Ltd 12th June 2000
Manual part no: DOC0029021E1 Page 16 Document No: OS-MA-D0002-902.1E1
Contact dCS on + 44 1799 531 999 email to: more@dcsltd.co.uk
(inside the UK replace + 44 with 0) web site: www.dcsltd.co.uk
dCS equipment encodes messaging into the various data streams to enable
receiving equipment to tell what is going on, and to decide which wire is which,
in the unlikely event of user wiring errors. Not all equipment from other
manufacturers does this, so:
IMPORTANT! Take care when connecting Dual AES as it is easy to connect the wires in the
wrong order. If this is not detected, the Left and Right channels will be
swapped on the recording. Numbering each connector is a sensible
precaution.
Sample Rate Display -
The main LED display generally shows the sample rate, in kS/s. When other
parameters are set, it briefly shows the new setting (Word Length, Noise
Shaping, etc) then reverts to its normal display. In the case of an error condition,
it will display an error message.
If the unit is being slaved, the display also indicates which input connector it is
slaved to.
xxx The sample rate, in kS/s (32, 44.1, 48, 88.2 or 96).
b xxx Slaved to Clk In.
r xxx Slaved to AES Reference in.
d xxx Temporary display during locking – the unit has
detected the base reference sample rate and is
attempting to lock to it.
. xxx Temporary display during locking – the unit is lining
up Clk Out to Clk in.
Important error messages are given below – a full list is given in the section
Error Codes and Messages on page 58.
BadFs The clock source is not in pull-in range, or is poorly
formatted. The unit cannot lock to it.
Err.xy An error has been detected. Please refer to
“Internal Device Error Codes” on page 58 for
more specific details on error codes.
Hot The unit is overheating, probably due to inadequate
ventilation. Please check positioning and cooling.
Ouch The “Hot” warning has been ignored and the unit is
getting so hot damage may follow.
(blank) If the display is completely blank for any significant
period, try switching off for 10 seconds then
switching on again. If this does not solve the
problem, contact your distributor or dCS.
The display is also used for Menu options.