Section 1
OPERA UNICA 12 cod. 420120269Q REV.1.0
www.dbtechnologies.com info@dbtechnologies-aeb.com
X-on a 35 mm tripode stand,
aliscaff mounting,
Z
Thank you for choosing a dBTechnologies Product!
The new OPERA UNICA 12 is a lightweight and versatile active speaker, designed for the use in live or installed scenarios. It is equipped with one 1” compression driver (1.75” voice coil), and one 12” neodymium woofer (3” voice coil). The dispersion pattern is asymmetrical on vertical axis, and it is diversified (top and bottom) on the horizontal one. This allows a good coverage also in case of reverberant environment. The amplifier (900 W RMS) is controlled by a powerful DSP, which use FIR filters in audio real-time processing. Eight presets are available for different equalization settings, in stacked or wedge use. Various optional accessories are available for all configuration needs. RDNet connections enhance the control possibilities also in complex scenarios (for example in multiple installations).
Check the site www.dbtechnologies.com for the complete user manual!
1) Unpacking
The box contains: No. 1 OPERA UNICA 12 No. 1 fuse No. 1 Mains cable This quick start and warranty documentation
2) Easy installation
OPERA UNICA 12 is equipped with:
a) vertical coverage: 85° asymmetrical (+25°/-60°)
b) horizontal coverage: 110° (85° in the upper part, 120° in the lower one)
The main admitted configurations, thanks also to various accessories like wall bracket WB-OP12, as shown in the picture below, are:
X – on a tripod stand (the maximum admitted height from floor and the base of loudspeaker is 1,6 m)
Y – with wall bracket in truss mounting (via aliscaff) Z – wall mounted W– wedge (monitor configuration on the stage)
Tilted side (A) for monitor (wedge) positioning
Pole mount (36 mm) (B) for tripod stand mounting
Upper and side (C) handles, which allow an easy displacement
NEVER USE THE HANDLES TO SUSPEND THE SPEAKER!
Some installation examples:
Y-with wall bracket and truss adapter for
-wall-mounted, W-wedge (in monitor configuration)
The dispersion pattern is asymmetrical on the vertical axis, and the horizontal coverage varies within position: It is wider in the lower side and narrow in the upper one. As shown in the following picture, the related dispersion pattern data are:
For further information about accessories and admitted configurations, please refer to the complete user manual.
OPERA UNICA 12 cod. 420120269Q REV.1.0
www.dbtechnologies.com info@dbtechnologies-aeb.com
120V~ voltage range:
3) Connections and controls
All the connections and controls are in the amplifier panel side:
a) Connect the audio input [1]. In case of dynamic microphone, select “MIC” in input sensitivity switch [3], otherwise select “LINE”. Adjust the Input Sensitivity level [2]. b) If you need to send the audio signal to a second speaker, connect the “Balanced Output” [4] to the Input on [1] of another OPERA UNICA 12 (for example) using a cable with XLR (balanced) connector. c) Set properly the DSP preset rotary [6], choosing between on stand “S”, wedge “W” configurations, or apply HPF filters “H”. The settings possibilities are:
S1– Playback, for tracks (like mp3 reproduction) S2– Bass boost, with a low-frequencies enhancement S3– Vocal enhance, for an optimization in vocal and singing performances H1 – HPF 90 Hz - Apply high-pass filter with 90 Hz cutoff frequency, for a little bass reduction H2 – HPF 120 Hz - Apply high-pass filter with 120 Hz cutoff frequency, for a strong bass reduction W1– Wedge, designed for reproduction in monitoring (wedge) use FLAT – designed for coherent source reproduction
d) In case of remote control, connect the proper Data Input [7] to the hardware remote controller (RDNet Control 2 or RDNet Control 8) with cables equipped with etherCON connectors. Then connect the Data Output [8] to the Data Input [7] of a second OPERA UNICA, and so on. When the RDNet network is on and it has recognized the connected device, the LED “Link” [9] is on. The other LED [9] “Active” start blinking when there is the presence of data transmission, the “Remote Preset Active” advise that all the local controls set on the amplifier panel (level, DSP presets, etc.) are by-passed and controlled remotely by the software AURORA NET. See also RDNet Control 2, Control 8 and AURORA NET user manuals for further information.
e) Plug the mains Input [11] and Link [12] (powerCON) cables. The Signal/ON led starts blinking, signaling the presence of audio signal.
WARNING
The speaker is supplied with a mounted fuse for operation within the 220-240V~ range. If you need to operate in the 110-
1–Balanced input (XLR connector type) 2–Input sensitivity control 3–Input sensitivity type switch (MIC/LINE)
4–Balanced output Link (XLR connector type) 5–Status LEDs (Limiter-Signal-Status-ON)
6–DSP Preset rotary with reference table 7–RDNet DATA IN 8–RDNet DATA OUT 9–RDNET control LEDs 10–USB Data Service 11–Auto-range Mains Input 12–Mains Link 13–Mains Fuse
1. Disconnect all connections, including the power supply.
2. Wait for 5 minutes.
3. Replace the fuse with the one provided in the package for the 100-120V~ range
Check the complete user manual on www.dbtechnologies.com for further information about the system and available accessories.
Scarica il manuale completo da www.dbtechnologies.com per ogni ulteriore informazione sul sistema e sugli accessori disponibili.
Für weitere Informationen und verfügbares Zubehör lesen sie bitte die vollständige Bedienungsanleitung unter
www.dbtechnologies.de.
Vérifiez le manuel de l'utilisateur complet sur www.dbtechnologies.com pour des informations complémentaires du système et des accessoires disponibles.
Compruebe el manual de usuario completo sobre
www.dbtechnologies.com para la información adicional sobre el sistema
y accesorios disponibles.
OPERA UNICA 12 cod. 420120269Q REV.1.0
www.dbtechnologies.com info@dbtechnologies-aeb.com
App to download the
Technical Data
Speaker Type: 2-way active speaker Usable Bandwidth [-10 dB]: 67 – 20000 Hz Frequency Response [-6 dB]: 73 – 20000 Hz Max SPL (1 m): 132 dB HF compression driver: 1 " Exit HF voice coil: 1.75” LF: 12” (Neodymium) LF Voice Coil: 3” Crossover frequency: 1600 Hz FIR filters: yes Horizontal dispersion: 110° (85° up / 120° down) Vertical dispersion: 85° (+25°/ -60°)
Amplifier
Amp Technology: Digipro® G3 Auto-range Amp Class: Class-D RMS Power: 900 W Peak Power: 1800 W
Operating voltage:
220-240V~ (50-60 Hz) or 100-120V~ (50-60 Hz)
Scan with your QR Reader
Processor
Controller: 56 bit DSP, 24 bit/48 kHz AD/DA converter Limiter: Peak, RMS, Thermal Controls: DSP rotary control (8 presets), Input
sensitivity switch, input sensitivity level
Input/Output
Mains/link connections: powerCON® type Signal Input/Link: Balanced XLR type RDNet connections: Data in, Data out Daisy chain power connection (max number of OPERA UNICA 12): 6 (1+5) (220-240V~) / 3 (1+2) (100-120V~)
Mechanics
Housing: Polypropylene Grille: Full grille Rigging points: (2x) M10 on top + (1x) M10 on the rear Pole Mount: yes, 36 mm diameter Width: 350 mm (13.78 in) Height: 642 mm (25.28 in) Depth: 349 mm (13.74 in) Weight: 15 kg (33.07 lbs.)
complete User Manual
Download the complete user manual on:
www.dbtechnologies.com/EN/Downloads.aspx
EMI CLASSIFICATION
According to the standards EN 55103 this equipment is designed and suitable to operate in E3 (or lower E2, E1) Electromagnetic environments.
FCC CLASS B STATEMENT ACCORDING TO TITLE 47, PART 15, SUBPART B, §15.105
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
WARNING: Make sure that the loudspeaker is securely installed in a stable position to avoid any injuries or damages to persons or properties. For safety reasons do not place one loudspeaker on top of another without proper fastening systems. Before hanging the loudspeaker check all the components for damages, deformations, missing or damaged parts that may compromise safety during installation. If you use the loudspeakers outdoor avoid spots exposed to bad weather conditions. Contact dB Technologies for accessories to be used with speakers. dBTechnologies will not accept any responsibility for damages caused by inappropriate accessories or additional devices.
Features, specification and appearance of products are subject to change without notice. dBTechnologies reserves the right to make changes or improvements in design or manufacturing without assuming any obligation to change or improve products previously manufactured.
OPERA UNICA 12 cod. 420120269Q REV.1.0
Loading...