Warnings and Precautions
1. Read all of these warnings and save them for later reference.
2. Follow all warnings and instructions marked on this unit.
3. Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use this unit in or near water.
5. Do not place this unit on an unstable cart, stand, or table. The unit may fall, causing serious damage.
6. Slots and openings on the cabinet top, back, and bottom are provided for ventilation. To ensure safe and reliable operation of this unit, and to protect it from overheating, do not block or cover these openings. Do not place this unit on a bed, sofa, rug, or similar surface, as the ventilation openings on the bottom of the cabinet will be blocked. This unit should never be placed near or over a heat register or radiator. This unit should not be placed in a built-in installation unless proper ventilation is provided.
7. This product should only be operated from the type of power source indicated on the marking label of the AC adapter. If you are not sure of the type of power available, consult your Datavideo dealer or your local power company.
8. Do not allow anything to rest on the power cord. Do not locate this unit where the power cord will be walked on, rolled over, or otherwise stressed.
9. If an extension cord must be used with this unit, make sure that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord’s rating.
10. Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes.
11. Never push objects of any kind into this unit through the cabinet ventilation slots, as they may touch dangerous voltage points or short out parts that could result in risk of fire or electric shock. Never spill liquid of any kind onto or into this unit.
12. Except as specifically explained elsewhere in this manual, do not attempt to service this product yourself. Opening or removing covers that are marked “Do Not Remove” may expose you to dangerous voltage points or other risks, and will void your warranty. Refer all service issues to qualified service personnel.
13. Unplug this product from the wall outlet and refer to qualified service personnel under the following conditions:
a. When the power cord is damaged or frayed; b. When liquid has spilled into the unit; c. When the product has been exposed to rain or water; d. When the product does not operate normally under normal operating conditions. Adjust
only those controls that are covered by the operating instructions in this manual; improper adjustment of other controls may result in damage to the unit and may often require
extensive work by a qualified technician to restore the unit to normal operation; e. When the product has been dropped or the cabinet has been damaged; f. When the product exhibits a distinct change in performance, indicating a need for service.
Warranty
1
Datavideo warrants that the equipment it manufactures shall be free from defects in material and workmanship for a period of 12 months from the date of product purchased. If equipment fails due to such defects, Datavideo will, at its option, repair or provide a replacement for the defective part or product. Equipment that fails after the warranty period, has been operated or installed in a manner other than that specified by Datavideo, or has been subjected to abuse or modification, will be repaired for time and material charges at the Buyer’s expense. This warranty does not affect your statutory rights within the Country of purchase.
For EU Customers only - WEEE Marking.
This symbol on the product indicates that it will not be treated as household waste. It must be handed over to the applicable take-back scheme for the recycling of electrical and electronic equipment. For more detailed information about the recycling of this product, please contact your local Datavideo office.
Introduction
The ITC-100 is a 19” Rack Mount 8 Way Intercom / Talkback System. It incorporates tally indicators for each channel and individual channel call buttons as well as a call all channels button. It is ideal in a live environment and enables easy bi-directional communication between all members of the crew. It is a perfect accessory for the Datavideo SE-1000 vision mixers.
2
Contents
WARNINGS AND PRECAUTIONS WARRANTY INTRODUCTION PACKING LIST FRONT PANEL CONNECTIONS REAR PANEL CONNECTIONS ITC-100SL SLAVE UNIT USING THE ITC-100 WITH THE SE-1000 / TB-10 ITC-100 TALLY INPUT PIN CROSS REFERENCE SPECIFICATIONS SERVICE AND SUPPORT
Packing List
1 2 2 3 4 6 7
9 10 11 13
1. ITC-100 KF 1000 Main Unit x 1
2. ITC-100SL Slave Unit x 6
3. ITC-100SL Carrying Case x 6
4. 20m XLR to XLR Intercom Cable x 6
5. MC-1 Headset / Microphone x 6
6. MC-2 XLR Gooseneck Mic x 1
7. LP-1 XLR Gooseneck Light x 1
8. 12V 3.0A Power Supply Unit x 1
9. AC Power cord. x 1
10. Instruction Manual x 1
3
Front Panel:
On / Off Switch
Powers the ITC-100 On / Off. Red LED indicates that unit is switched on.
XLR Microphone Socket
Combined XLR / ¼” (6.3mm) Jack Microphone Input for either a Condenser or Dynamic Gooseneck Microphone. XLR supports Condenser Microphones ¼” (6.3mm) Jack supports Dynamic.
Headphone Socket
¼ “ / 6.3mm Stereo Headphone Socket for conventional headphones. Plugging in headphones will disable the built-in speaker
Microphone / Headset Socket
3.5mm Stereo Socket for combined Microphone Headset. Plugging in a Microphone / Headset will disable the built-in speaker and the XLR Microphone Input.
ALL Button
Opens communication with all channels. All channels will hear communication from the operator, or from any other channel using the TALK button.