Type Number
Designation IEC
System
UL Recognition
Nominal Voltage
Rated Capacity (0.2 C / 1.0 V)
Impedance AC at 1 kHz, fully charged
Typical Capacity at
0.2 C / 1.00 V
Max Discharge Current (cont. / 1.0 V)
Dimensions
Diameter (a)
Height (b)
Cap Diameter (d)
Weight, approx
Charge Conditions
Standard Charge
Fast Charge (charge termination control
recommended).
Control parameters
Trickle Charge (0.05 - 0.1 C)
Temperature Range
Storage 1 Year (1
6 Month
1 Month
(1)
recharge every 6 months
Charge
Fast Charge
Discharge
Rechargeable Cylindrical Cells (NiMH)
55171
HR 11 / 45
NiMH
MH13654
1.2 V
700 mAh
< 40 mOhm
730 mAh
2100 mA
10.5
43.7
– 0.7
– 1.0
mm
mm
4.7 mm
13 g
70 mA / 16 h (t
max
350 mA to 700 mA
(0.5 to 1 C)
-∆U = 0 – 5 mV
DT / dt = 0.8°C / min (0.5 to 0.9 C)
0.8 °C – 1°C / min (1 C)
Temp. cut-off = 45 – 50 °C
Timer: 105 % nominal input
35 - 70 mA
-20 °C - +25 °C
-20 °C - +35 °C
-20 °C - +45 °C
0 °C - 45 °C
10 °C - 45 °C
-20 °C - 50 °C
VARTA Microbattery GmbH
Daimlerstraße 1, 73479 Ellwangen, Germany
Tel.: +49 79 61 921-0
Telefax: +49 79 61 921-553
)
Fo_171