NICHIA Product Guide
Violet Laser Diode
NDHV310APB
Features
•
• Single Transverse Mode
•
Optical Output Power: 30mW
Can Type: φ 5.6 with Photo Diode
Absolute Maximum Ratings
Item
Optical Output Power
Reverse Voltage
Storage Temperature
Operating Case Temperature
Initial Electrical/Optical Characteristics (Tc=25°C, Po=30mW/CW)
Item
Symbol Min Typ. Max Unit
Optical Output Power
LD
PD
Symbol
Po 35
Vr
(LD)
5 V
(PD)
Vr
20 V
Tstg -35 ~ 85
Tc -10 ~ 60
Po - 30 - mW
Absolute Maximum Ratings
1. LD Anode
2. PD Anode
3. Common
2
PD
Unit
mW
°C
°C
1
LD
3
Peak Wavelength*
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
FWHM Beam Divergence
Emission Point
Accuracy
Monitor Current**
All figures in this specification are measured by Nichia's method and may contain measurement deviations
*: FWHM < 1nm
**: When used at 30mW by monitor APC drive and Temperature is changed from 20
may increase or decrease up to 10%. Also, when used at constant temperature 25
drive, optical output may change up to 5% in 24 hours.
If your application requires precise output power control, monitor current should not be used as reference for
output power. Use additional external PD to monitor output power.
NICHIA CORPORATION
HEAD OFFICE: P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN
PHONE: +81-884-22-2311 FAX: +81-884-23-1802
CONTACT
TOKYO SALES DEPARTMENT OPTOELECTRONICS PRODUCTS DIV.: 13F TAMACHI CENTER BUILDING, 34-7,
SHIBA 5-CHOME, MINATO-KU, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108 FAX: +81-3-5440-7330
E-mail:
UTZ-SC0009_0
Angle
Position
p
λ
Ith - 45 60 mA
Iop - 70 90 mA
η
Vop - 4.5 5.5 V
θ//
θ⊥
θ//
∆
θ⊥
∆
X, Y, Z
∆
Im 0.1
laser@tokyo.nichia.co.jp
-1-
400 408 415 nm
0.7 1.2
5 8 13
18 24 30
- -
- -
-
-
0.25
1.6 W/A
±2.5
±3
±80 µm
0.6 mA
C to 60 °C, optical output
°
C, 30mW by monitor APC
°
°
°
°
°
http://www.nichia.co.jp

NICHIA Product Guide
Typical Characteristics
Optical Output Power vs. Forward
Current
30
20°C
40°C
20
10
Optical Output Power Po [mW]
0
020406080
1
0.8
0.6
0.4
Relative Intensity
0.2
0
-60 -40 -20 0 20 40 60
60°C
Tc=25°C
Po=30mW
Forward Current If [mA]
Far Field Pattern
θ⊥
θ//
Angle θ [°]
Forward Voltege vs. Forward
Current
6
5
4
3
2
Forward Voltage Vf [V]
1
0
0 20406080
Forward Current If [mA]
Frequency Response
3
2
1
0
-1
-2
-3
Relative Intensity [dB]
-4
-5
01234
Frequency [GHz]
30mW5mW
20°C
40°C
60°C
Tc=25°C
Typical Spectrum
Peak Wavelength vs. Case
Temperature
Tc=25°C
Po=30mW
Relative Optical Output Power
406 407 408 409 410
Wavelength λ [nm]
UTZ-SC0009_0
-2-
414
Po=30mW
412
[nm]
λ
410
408
406
Peak Wavelength
404
10 20 30 40 50 60 70
Case Temp Tc [°C]

NICHIA Product Guide
Outline Dimension
Top Vi e w
φ 5.6
φ 4.2 ± 0.2
φ 3.55 ± 0.1
+0
-0.03
Bottom View
Y +
2
(90°)
1
X
+
(0.4)
0.25±0.03 Glass Thickness
Emitting Point
1.3±0.08
Reference Plane
3×φ0.45±0.1
Connection
Connection
PD
2
φ 2.0 ± 0.2
3
1
LD
1. LD Anode
2. PD Anode
3. Common
( ) are reference figures
2.3±0.2
0.4±0.1
1.0±0.1
(φ 1.6)
φ 3.55 ± 0.1
Side View
1.2±0.1
6.5±1.0
Safety of Laser light
Laser light can damage the human eye and the eyes of
animals. Do not look at any laser light directly or through
any optical lens. When handling a laser diode, do not look
directly at the light generated by it. Wear appropriate safety
glasses to prevent light from entering the eye by reflection off
of another surface.
Nichia LDs are classified in Class 3B of IEC60825-1 and 21
CFR Part 1040.10 Safety Standards. It is absolutely
necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are
incorporated and/or integrated.
Operating method
Laser diodes are to change forward voltage and light output power due to the fluctuation in temperature etc.
They have some tendency to gradually increase electric current necessary to keep the output power constant
during their operation. When precise optical output control is required, it is recommended to use an external
photo diode to monitor output power and use APC (Automatic Power Control) function in the operating
circuit.
Cautions on LD handling
Static Electricity and surge damage the LDs. It is recommended to use a wrist strap or anti-electrostatic glove
when handling the Product.
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as
office equipment, communications equipment, measurement instruments and household appliances). Consult
Nichia’s sales staff in advance for information on the applications in which exceptional quality and reliability
are required, particularly when the failure or malfunction of the LDs may directly jeopardize life or health
(such as for airplanes, aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic
control equipment, life support systems and safety devices).
The specifications of the Product may be modified for improvement without prior notice. The formal
specifications must be exchanged and signed by both parties before a user starts mass production.
Strictly prohibited are reverse engineering and disassembly concerning, but not limited to, structure and
composition of the Product.
Caution-use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure.
UTZ-SC0009_0
-3-