MITSUMI
Sync Detector MM1021
Absolute Maximum Ratings
(Ta=25°C)
Electrical Characteristics
(Except where noted otherwise, Ta=25°C, VCC=9.0V, SW1=ON, SW2~SW7=1)
Item Symbol Ratings Units
Storage temperature T
STG
-
40~+125 °C
Operating temperature T
OPR
-
20~+75 °C
Power supply voltage V
CC 14.0 V
Allowable loss Pd 500 mW
Item
Symbol
Measurement
Measurement conditions Min. Typ. Max. Units
circuit
Operating power supply voltage range
VCC
--
7.0 9.0 13.0 V
Consumption current Id
-
SW1=OFF, SW7=2 6.5 11.0 mA
Comparator input H V
IH TP8 SW6=2, TP5=H L 5.8 6.0 6.2 V
voltage L V
IL TP8 SW6=2, TP5=L H 3.6 3.8 4.0 V
Comparator output H V
OH TP5 SW6=2, TP8=3.0V 8.1 8.9 V
voltage L V
OL TP5 SW6=2, TP8=6.5V 0 0.1 V
Free-running frequency
PAL fOP TP1 500 kHz
NTSC f
ON TP1 SW3=SW4=2 503 kHz
Oscillation output voltage V
O TP1 1.9 VP-P
Sync discrimination input level VIN TP2 SW2=2, TP5=H L
-
12 dB
Sync separation working current
IIN TP4 SW5=2, TP5=L H 100 125 150 µA
Sync discrimination voltage
V8
H TP8 SW2=2, TP2=0dB 7.2 V
V8
L TP8 SW2=2, TP2=
-
20dB 0 V
Capture range
PAL f
CP TP3
SW2=3, SW4=1, TP5=H L *1
150 200 Hz
NTSC f
CN TP3
SW2=3, SW4=2, TP5=H L *1
150 200 Hz
Pin 7 output voltage
H V7
H TP7
SW2=2
*
2
0.87 0.90 0.93 V
L V7
L TP7 0.20 0.40 V
Pin 6 voltage V6 TP6 SW5=3 6.7 V
Note : *1
Capture range : fcp, fcn
The smaller of fc1 and fc2 values are fcp and fcn.
Note :
*
2