Datasheet HCPL-4100 Datasheet (HP)

Page 1
1-361
H
Optically Coupled 20 mA Current Loop Transmitter
Technical Data
HCPL-4100
Features
• Guaranteed 20 mA Loop Parameters
• Data Input Compatible with LSTTL, TTL and CMOS Logic
• Guaranteed Performance over Temperature (0°C to 70°C)
• Internal Shield for High Common Mode Rejection
• 20 kBaud Data Rate at 400 Metres Line Length
• Guaranteed On and Off Output Current Levels
• Safety Approval
UL Recognized -2500 V rms for
1 minute
CSA Approved
• Optically Coupled 20 mA Current Loop Receiver, HCPL-4200, Also Available
Applications
• Isolated 20 mA Current Loop Transmitter in:
Computer Peripherals Industrial Control Equipment Data Communications
Equipment
Description
The HCPL-4100 optocoupler is designed to operate as a transmit­ter in equipment using the 20 mA current loop. 20 mA current loop systems conventionally signal a logic high state by transmitting 20 mA of loop current (MARK), and signal a logic low state by allowing no more than a few milliamperes of loop current (SPACE). Optical coupling of the signal from the logic input to the 20 mA current loop breaks ground loops and provides very high immunity to common mode interference.
The HCPL-4100 data input is compatible with LSTTL, TTL, or CMOS logic gates. The input integrated circuit drives a GaAsP LED. The light emitted by the LED is sensed by a second inte­grated circuit that allows 20 mA to pass with a voltage drop of less than 2.7 volts when no light is emitted and allows less than 2 mA to pass when light is emitted. The transmitter output is capable of withstanding 27 volts. The input integrated circuit provides a controlled amount of LED drive current and takes into account any LED light output degrada­tion. The internal shield allows a guaranteed 1000 V/µs common mode transient immunity.
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD.
Functional Diagram
A 0.1 µF bypass capacitor connected between pins 8 and 5 is recommended.
5965-3581E
Page 2
1-362
Ordering Information
Specify part number followed by Option Number (if desired).
HCPL-4100# XXX
300 = Gull Wing Surface Mount Lead Option 500 = Tape/Reel Package Option (1 K min)
Option data sheets available. Contact your Hewlett-Packard sales representative or authorized distributor for information.
Package Outline Drawings
8-Pin DIP Package (HCPL-4100)
9.65 ± 0.25
(0.380 ± 0.010)
1.78 (0.070) MAX.
1.19 (0.047) MAX.
HP XXXX
YYWW
DATE CODE
1.080 ± 0.320
(0.043 ± 0.013)
2.54 ± 0.25
(0.100 ± 0.010)
0.51 (0.020) MIN.
0.65 (0.025) MAX.
4.70 (0.185) MAX.
2.92 (0.115) MIN.
DIMENSIONS IN MILLIMETERS AND (INCHES).
5678
4321
5° TYP.
TYPE NUMBER
UL RECOGNITION
UR
0.254
+ 0.076
- 0.051
(0.010
+ 0.003)
- 0.002)
7.62 ± 0.25
(0.300 ± 0.010)
6.35 ± 0.25
(0.250 ± 0.010)
Page 3
1-363
8-Pin DIP Package with Gull Wing Surface Mount Option 300 (HCPL-4100)
240
T = 115°C, 0.3°C/SEC
0
T = 100°C, 1.5°C/SEC
T = 145°C, 1°C/SEC
TIME – MINUTES
TEMPERATURE – °C
220 200 180 160 140 120 100
80 60 40 20
0
260
123456789101112
Thermal Profile (Option #300)
Figure 1. Maximum Solder Reflow Thermal Profile. (Note: Use of non-chlorine activated fluxes is recommended.)
0.635 ± 0.25
(0.025 ± 0.010)
12° NOM.
9.65 ± 0.25
(0.380 ± 0.010)
0.635 ± 0.130
(0.025 ± 0.005)
7.62 ± 0.25
(0.300 ± 0.010)
5
6
7
8
4
3
2
1
9.65 ± 0.25
(0.380 ± 0.010)
6.350 ± 0.25
(0.250 ± 0.010)
1.016 (0.040)
1.194 (0.047)
1.194 (0.047)
1.778 (0.070)
9.398 (0.370)
9.906 (0.390)
4.826
(0.190)
TYP.
0.381 (0.015)
0.635 (0.025)
PAD LOCATION (FOR REFERENCE ONLY)
1.080 ± 0.320
(0.043 ± 0.013)
4.19
(0.165)
MAX.
1.780
(0.070)
MAX.
1.19
(0.047)
MAX.
2.54
(0.100)
BSC DIMENSIONS IN MILLIMETERS (INCHES). LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
0.254
+ 0.076
- 0.051
(0.010
+ 0.003)
- 0.002)
Page 4
1-364
Regulatory Information
The HCPL-4100 has been approved by the following organizations:
UL
Recognized under UL 1577, Component Recognition Program, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5, File CA
88324.
Insulation and Safety Related Specifications
Parameter Symbol Value Units Conditions
Min. External Air Gap L(IO1) 7.1 mm Measured from input terminals to output (External Clearance) terminals, shortest distance through air
Min. External Tracking Path L(IO2) 7.4 mm Measured from input terminals to output (External Creepage) terminals, shortest distance path along body
Min. Internal Plastic Gap 0.08 mm Through insulation distance, conductor to (Internal Clearance) conductor, usually the direct distance
between the photoemitter and photodetector inside the optocoupler cavity
Tracking Resistance CTI 200 Volts DIN IEC 112/VDE 0303 PART 1 (Comparative Tracking Index)
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
(No Derating Required up to 55°C)
Storage Temperature .................................................. -55°C to +125°C
Operating Temperature ................................................. -40°C to +85°C
Lead Solder Temperature .... 260°C for 10 s (1.6 mm below seating plane)
Supply Voltage – VCC.............................................................. 0 V to 20 V
Average Output Current - IO........................................ -30 mA to 30 mA
Peak Output Current - IO........................................... Internally Limited
Output Voltage – VO........................................................ -0.4 V to 27 V
Input Voltage – VI............................................................ -0.5 V to 20 V
Input Power Dissipation – PI................................................. 265 mW
[1]
Output Power Dissipation – PO............................................. 125 mW
[2]
Total Power Dissipation – P .................................................. 360 mW
[3]
Infrared and Vapor Phase Reflow Temperature
(Option #300) ..........................................see Fig. 1, Thermal Profile
Page 5
1-365
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Power Supply Voltage V
CC
4.5 20 Volts
Input Voltage Low V
IL
0 0.8 Volts
Input Voltage High V
IH
2.0 20 Volts
Operating Temperature T
A
070 °C
Output Voltage V
O
0 27 Volts
Output Current I
O
024 mA
DC Electrical Specifications
For 0°C TA 70°C, 4.5 V VCC 20 V, all typicals at TA = 25°C and VCC = 5 V unless otherwise noted. See note 12.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Mark State Output V
MO
1.8 2.25 Volts IO = 2 mA VI = 2.0 V 2, 3
Current 2.2 Volts IO = 12 mA
2.35 2.7 Volts IO = 20 mA
Mark State Short I
SC
30 85 mA VI = 2 V, VO = 5 V to 27 V 4 Circuit Output Current
Space State Input I
SO
0.5 1.1 2.0 mA VI = 0.8 V, VO = 27 V 4
Current Low Level Input I
IL
-0.12 -0.32 mA VCC = 20 V, VI = 0.4 V
Current Low Level Input V
IL
0.8 Volts
Voltage High Level Input V
IH
2.0 Volts
Voltage High Level Input I
IH
20 µAVI = 2.7 V
Current 100 µAVI = 5.5 V
0.005 250 µAVI = 20 V
Supply Current I
CC
7.0 11.5 mA VCC = 5.5 V 0 V VI 20 V
7.8 13 m A VCC = 20 V
Page 6
1-366
Switching Specifications
For 0°C TA 70°C, 4.5 V VCC 20 V, all typicals at TA = 25°C and VCC = 5 V unless otherwise noted. See note 12.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note
Propagation Delay Time t
PLH
0.3 1.6 µsCO = 1000 pF, 5, 6, 6
to Logic High Output Level CL = 15 pF, 7
IO = 20 mA
Propagation Delay Time t
PHL
0.2 1.0 µsCO = 1000 pF, 5, 6, 7
to Logic Low Output Level CL = 15 pF, 7
IO = 20 mA
Propagation Delay Time t
PLH
- t
PHL
0.1 µsIO = 20 mA
Skew Output Rise Time t
r
16 ns IO = 20 mA, 6, 8 8
(10-90%) CO = 1000 pF,
CL = 15 pF
Output Fall Time t
f
23 ns IO = 20 mA, 6, 8 9
(90-10%) CO = 1000 pF,
CL = 15 pF
Common Mode Transient |CMH| 1,000 10,000 V/µsVI = 2 V, 9, 10 10 Immunity at Logic High TA = 25°C Output Level VCM = 50 V (peak),
VCC = 5 V IO (min.) = 12 mA
Common Mode Transient |CML| 1,000 10,000 V/µsVI = 0.8 V, 9, 10 11 Immunity at Logic Low TA = 25°C Output Level VCM = 50 V (peak),
VCC = 5 V IO (max.) = 3 mA
Package Characteristics
For 0°C TA 70°C, unless otherwise specified. All typicals at TA = 25°C.
Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Notes
Input-Output Momentary V
ISO
2500 V rms RH 50%, t = 1 min,
Withstand Voltage* TA = 25°C 5, 13 Resistance, Input-Output R
I-O
10
12
ohms V
I-O
= 500 V dc 5
Capacitance, Input-Output C
I-O
1 pF f = 1 MHz,
V
I-O
= 0 V dc 5
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable), your equipment level safety specification, or HP Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
Page 7
1-367
Notes:
1. Derate linearly above 55°C free air temperature at a rate of 3.8 mW/°C. Proper application of the derating factors will prevent IC junction temperatures from exceeding 125°C for ambient temperatures up to 85°C.
2. Derate linearly above a free-air temperature of 70°C at a rate of 2.3 mW/°C. A significant amount of power may be dissipated in the HCPL-4100 output circuit during the transition from the SPACE state to the MARK state when driving a data line or capacitive load (C
OUT
). The average power dissipation during the transition can be estimated from the following equation which assumes a linear discharge of a capacitive load: P = ISC (VSO + VMO)/2, where VSO is the output voltage in the SPACE state. The duration of this transition can be estimated as t = C
OUT
(VSO ­VMO)/ISC. For typical applications driving twisted pair data lines with NRZ data as shown in Figure 11, the transition time will be less than 10% of one bit time.
3. Derate linearly above 55°C free-air temperature at a rate of 5.1 mW/°C.
4. The maximum current that will flow into the output in the mark state (ISC) is internally limited to protect the device. The duration of the output short circuit shall not exceed 10 ms.
5. The device is considered a two terminal device, pins 1, 2, 3, and 4 are connected together, and pins 5, 6, 7, and 8 are connected together.
6. The t
PLH
propagation delay is measured from the 1.3 volt level on the leading edge of the input pulse to the 10 mA level on the leading edge of the output pulse.
7. The t
PHL
propagation delay is measured from the 1.3 volt level on the trailing edge of the input pulse to the 10 mA level on the trailing edge of the output pulse.
8. The rise time, tr, is measured from the 10% to the 90% level on the rising edge of the output current pulse.
9. The fall time, tf, is measured from the 90% to the 10% level on the falling edge of the output current pulse.
10. Common mode transient immunity in the logic high level is the maximum (positive) dVCM/dt on the leading edge of the common mode pulse, VCM, that can be sustained with the output in a Mark ("H") state (i.e., IO> 12 mA).
11. Common mode transient immunity in the logic low level is the maximum (positive) dVCM/dt on the leading edge of the common mode pulse, VCM, that can be sustained with the output in a Space ("L") state (i.e., I
O
< 3 mA).
12. Use of a 0.1 µF bypass capacitor connected between pins 5 and 8 is recommended.
13. In accordance with UL 1577, each optocoupler is momentary withstand proof tested by applying an insulation test voltage 3000 V rms for 1 second (leakage detection current limit, I
i-o
5 µA).
Figure 2. Typical Mark State Output Voltage vs. Temperature.
Figure 3. Typical Output Voltage vs. Loop Current.
Figure 4. Typical Space State Output Current vs. Temperature.
V
O
– OUTPUT VOLTAGE – V
-40
1.6
1.2
T
A
– TEMPERATURE – °C
060
1.8
1.4
-20 20 40
2.0
2.2
2.4
2.6
2.8
3.0
80 100
IO
20 mA
12 mA
2 mA
VCC = 5 V
V
I
= 2 V
V
O
– OUTPUT VOLTAGE – V
0
1.0
0
I
O
– OUTPUT CURRENT – mA
10 20
1.5
0.5
515
2.0
2.5
3.0
3.5
25 30
VCC = 5 V V
I
= 2 V
TA = 25 °C
I
S
– SPACE CURRENT – mA
-40
0.8
0.6
T
A
– TEMPERATURE – °C
060
0.9
0.7
-20 20 40
1.0
1.1
1.2
1.3
80 100
VO
27 V
20 V
VCC = 5 V V
I
= 0.8 V
Page 8
1-368
t
p
– PROPAGATION DELAY – µs
-40
0.2
0
T
A
– TEMPERATURE – °C
060
0.3
0.1
-20 20 40
0.4
0.5
0.6
80 100
t
PLH
CO = 1000 pF C
L
= 15 pF
V
CC
= 5 V
I
O
= 20 mA
t
PHL
Figure 5. Test Circuit for t
PLH
, t
PHL
,
tr, and tf.
Figure 6. Waveforms for t
PLH
, t
PHL
, tr, and tf.
Figure 7. Typical Propagation Delay vs. Temperature.
Figure 8. Typical Rise, Fall Times vs. Temperature.
t
r
, t
f
– RISE AND FALL TIMES – ns
-40
20
0
T
A
– TEMPERATURE – °C
060
30
10
-20 20 40
40
50
60
70
80 100
t
f
VCC = 5 V C
OUT
= 1000 pF
C
L
= 15 pF
I
O
= 20 mA
t
r
Figure 9. Test Circuit for Common Mode Transient Immunity.
Figure 10. Typical Waveforms for Common Mode Transient Immunity.
Page 9
1-369
Applications
Data transfer between equipment which employs current loop circuits can be accomplished via one of three configurations: simplex, half duplex or full duplex communication. With these configurations, point-to­point and multidrop arrangements are possible. The appropriate configuration to use depends upon data rate, number of stations, number and length of lines, direction of data flow, protocol, current source location and voltage compliance value, etc.
Simplex
The simplex configuration, whether point to point or multi­drop, gives unidirectional data flow from transmitter to trans­mitter(s). This is the simplest configuration for use in long line length (two wire), moderate data rate, and low current source compliance level applications. A block diagram of simplex point to point arrangement is given in Figure 11 for the HCPL-4100 transmitter optocoupler.
Major factors which limit maxi­mum data rate performance for a simplex loop are the location and compliance voltage of the loop current source as well as the total line capacitance. Application of the HCPL-4100 transmitter in a simplex loop necessitates thtat a non-isolated active receiver (containing current source) be used at the opposite end of the current loop. With long line length, large line capacitance will need to be charged to the compliance voltage level of the current source before the receiver loop current decreases to zero. This effect limits upper data rate performance. Slower data rates will occur with larger compliance voltage levels. The maximum compliance level is determined by the transmitter breakdown characteristic. In addition, adequate compliance of the current source must be available for voltage drops across station(s) during the MARK state in multidrop applications for long line lengths.
In a simplex multidrop applica­tion with multiple HCPL-4100 transmitters and one non-isolated active receiver, priority of transmitters must be established.
A recommended non-isolated active receiver circuit which can be used with the HCPL-4100 in point-to-point or in multidrop 20 mA current loop applications is given in Figure 12. This non­isolated active receiver current threshold must be chosen properly in order to provide adequate noise immunity as well as not to detect SPACE state current (bias current) of the HCPL-4100 transmitter. The receiver input threshold current is Vth/Rth 10 mA. A simple transistor current source provides a nominal 20 mA loop current over a VCC compliance range of 6 V dc to 27 V dc. A resistor can be used in place of the constant current source for simple applications where the wire loop distance and number of stations on the loop are fixed. A minimum transmitter output load capac­itance of 1000 pF is required between pins 3 and 4 to ensure absolute stability.
Length of current loop (one direction) versus minimum required DC supply voltage, VCC, of the circuit in Figure 12 is graphically illustrated in Figure
13. Multidrop configurations will require larger VCC than Figure 13 predicts in order to account for additional station terminal voltage drops.
Typical data rate performance versus distance is illustrated in Figure 14 for the combination of a non-isolated active receiver and HCPL-4100 optically coupled current loop transmitter shown in Figure 12. Curves are shown for
Figure 11. Simplex Point to Point Current Loop System Configuration.
Page 10
1-370
Figure 12. Recommended Non-Isolated Active Receiver with HCPL-4100 Isolated Transmitter for Simplex Point to Point 20 mA Current Loop.
25% distortion data rate at different VCC values. 25% distortion data rate is defined as that rate at which 25% distortion occurs to output bit interval with respect to the input bit interval. Maximum data rate (dotted line) is restricted by device character­istics. An input Non-Return-to­Zero (NRZ) test waveform of 16 bits (0000001011111101) was used for data rate distortion measurements. Enhanced speed performance of the loop system can be obtained with lower V
CC
supply levels, as illustrated in Figure 14. In addition, when loop current is supplied through a resistor instead of by a current source, an additional series termination resistance equal to the characteristic line impedance can be used at the HCPL-4100 transmitter end to enhance speed of response by approximately 20%.
The cable used contained five pairs of unshielded, twisted, 22 AWG wire (Dearborn #862205). Loop current is 20 mA nominal. Input and output logic supply voltages are 5 V dc.
Full Duplex
The full duplex point-to-point communication of Figure 15 uses
a four wire system to provide simultaneous, bidirectional data communication between local and remote equipment. The basic application uses two simplex point-to-point loops which have two separate, active, non-isolated units at one common end of the loops. The other end of each loop is isolated.
Figure 13. Minimum Required Supply Voltage, VCC, vs. Loop Length for Current Loop Circuit of Figure 13.
Figure 14. Typical Data Rate vs. Distance and Supply Voltage.
V
CC
– VOLTS
0
12
0
L – LOOP LENGTH (ONE DIRECTION) METERS
100 1000
16
4
28
32
36
40
10000
m
VCC = 0.00212 — (L) + 5.7 V
 R
CABLE
= 0.05296 /m
I
LOOP
= 20 mA
V
MARK
= 2.7 Vdc (HCPL-4100)
V
SAT
= 1.5 Vdc (CURRENT SOURCE)
T
A
= 25 °C
V
24 20
8
Page 11
1-371
As Figure 15 illustrates, the combination of Hewlett-Packard current loop optocouplers, HCPL­4100 transmitter and HCPL-4200 receiver, can be used at the isolated end of current loops. Cross talk and common mode coupling are greatly reduced when optical isolation is imple­mented at the same end of both loops, as shown. Full duplex data rate is limited by the non-isolated active transmitter current loop. Comments mentioned under simplex configuration apply to the full duplex case. Consult the HCPL-4200 receiver optocoupler data sheet for specified device performance.
Half Duplex
The half duplex configuration, whether point to point or multi­drop, gives non-simultaneous bidirectional data flow from transmitters to transmitters shown in Figures 16a and 16b.
This configuration allows the use of two wires to carry data back and forth between local and remote units. However, protocol must be used to determine which specific transmitter can operate at any given time. Maximum data rate for a half duplex system is limited by the loop current charging time. These considera­tions were explained in the Simplex configuration section.
Figures 16a and 16b illustrate half duplex application for the combination of HCPL-4100/-4200 optocouplers. The unique and complementary designs of the HCPL-4100 transmitter and HCPL-4200 receiver optocoup­lers provide many designed-in benefits. For example, total optical isolation at one end of the current loop is easily accom­plished, which results in substantial removal of common mode influences, elimination of
ground potential differences and reduction of power supply requirements. With this combina­tion of HCPL-4100/-4200 opto­couplers, specific current loop noise immunity is provided, i.e., minimum SPACE state current noise immunity is 1 mA, MARK state noise immunity is 8 mA.
Voltage compliance of the current source must be of an adequate level for operating all units in the loop while not exceeding 27 V dc, the maximum breakdown voltage for the HCPL-4100. Note that the HCPL-4100 transmitter will allow output loop current to conduct when input VCC power is off. Consult the HCPL-4200 receiver optocoupler data sheet for specified device performance.
For more information about the HCPL-4100/-4200 optocouplers, consult Application Note 1018.
Figure 15. Full Duplex Point to Point Current Loop System Configuration.
Page 12
1-372
Figure 16. Half Duplex Current Loop System Configurations for (a) Point to Point, (b) Multidrop.
Loading...