
Slim, Miniature Relay, Capable of
Relaying Programmable Controller and
Temperature Controller Outputs
■ Slim and miniature: 17.5 × 6.5 × 12.5 mm
(L × W × H).
■ Ideal for high-density mounting.
■ Switches 5 A at 250 VAC/30 VDC.
■ Allows 300,000 operations with a 2-A load at
250 VAC or 30 VDC.
■ Actual load switching capability equals the G6B’s
capability.
■ Washable construction.
Ordering Information
Classification Contact form Enclosure ratings Model
Standard SPST-NO Fully sealed G6D-1A-ASI
Note: When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI 12 VDC
Rated coil voltage
G6D PCB Relay
R
CE
Model Number Legend
G6D - - VDC
1 2 3 4
1. Number of Poles
1: 1 pole
2. Contact Form
A: SPST-NO
■ Accessories (Order Separately)
Connecting Socket P6D-04P
■ Coil Ratings
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 40 mA 16.7 mA 8.3 mA
Coil resistance 125 Ω 720 Ω 2,880 Ω
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 160% of rated voltage (at 23°C)
Power consumption Approx. 200 mW
Note: The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
3. Contact Material
ASI: Silver alloy (cadmium-free)
4. Rated Coil Voltage
5, 12, 24 VDC
1

■ Contact Ratings
Rated load 5 A at 250 VAC, 5 A at 30 VDC, resistive load
Rated carry current 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A
Max. switching power 1,250 VA, 150 W
Failure rate (reference value) 10 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10–6/operation
Characteristics
■
Contact resistance 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 6,000 V (1.2 x 50 µs) between coil and contacts
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Endurance Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 100 m/s
Electrical: 70,000 operations min. (5 A at 250 VAC/30 VDC, resistive load)
300,000 operations min. (2 A at 250 VAC/30 VDC, resistive load)
2
2
Ambient temperature Operating: −25°C to 70°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 3 g
G6DG6D
Engineering Data
Maximum Switching Power Ambient Temperature vs.
50
30
10
5
3
DC resistive
Switching current (A)
load
1
DC inductive
load
0.5
0.3
0.1
0 3 5 10 30 100 250 500 1,000 0 233040 50 6070 8090
AC resistive load
AC inductive
load
cosφ=0.4
Switching voltage (V)
Ambient Temperature vs.
Operating/Recovery Voltage
G6D-1A-ASI
100
Sample: G6D1A
Quantity: 5
80
60
40
20
0
−40 −20 0 20 40 60 80
Operating/recovery voltage (ratio of rated voltage) (%)
Ambient temperature (°C)
Operating voltage
Recovery voltage
max.
X
min.
max.
X
min.
Endurance
500
300
100
operations)
4
50
30
10
Endurance (x10
250-VAC/30-VDC resistive load
250-VAC/30 VDC inductive load
5
(cosφ=0.4/ L/R=7 ms)
3
1 2 3 4 5 6 7 8 9 10
0
Switching current (A)
Malfunctioning Shock
G6D-1A-ASI
Y
1,000
800
X
Z'
Not energized
Energized
Measurement conditions: Impose a shock in the
±X, ±Y, and ±Z directions three times each with
the Relay energized to check the shock values
that cause the Relay to malfunction.
600
400
200
206
Y'
Unit: m/s
Z
X'
2
Shock direction
XX'
Y
Y'
Coil terminals
Maximum Coil Voltage
200
180
160
140
120
Maximum coil voltage (%)
100
80
60
Ambient temperature (°C)
Note: The maximum coil voltage is the
maximum voltage that can be
applied to the relay coil
Z
Z'
2

G6DG6D
■ Approved Standards
• The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this catalog.
UL Approval (File No. E41515) UL508
Model Number of poles Coil ratings Contact ratings Number of test
G6D-1A-ASI 1 5 to 24 VDC 5 A, 250 VAC (General Use) 6,000
5 A, 30 VDC
CSA Approval (File No. LR31928) C22.2 No. 14
operations
Model Number of poles Coil ratings Contact ratings Number of test
G6D-1A-ASI 1 5 to 24 VDC 5 A, 250 VAC (General Use) 6,000
5 A, 30 VDC (Resistive)
EN/TÜV Approval (Registration No. R50029064/EN61810-1)
Model Number of poles Coil ratings Contact ratings Number of test
G6D-1A-ASI 1 5, 12, 24 VDC 5 A, 250 VAC (cosφ=1.0) 70,000
5 A, 30 VDC (0 ms)
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
G6D-1A-ASI
P6D-04P Socket
0.5
0.5
2.54
6.9 max.
(6.7)*
6+0.1
0.65
2.54
17.5 max.
(17.3)*
7.62.
19.7 max.
(19.5)*
0.8
5.08
*Average value
5.0876.2
*Average value
6.5 max.
(6.4)*
5.08
12.5 max.
(12.4)*
3.5
0.3
Terminal Arrangement/
Internal Connections
(Bottom View)
1
10.8
3.6
0.3
(0.86)
5.08
57
13
Mounting Holes
(Bottom View)
Tolerance: ±0.1
Four, 1.1-dia.
(2.18)
holes
15.24
operations
operations
2.54
2.54
(1.13)
2.54
2.54
Mounting Holes
(Bottom View)
Tolerance: ±0.1
Four, 1.1-dia.
holes
5.08
10.16
(0.71)
5.08
3

Precautions
G6DG6D
More than two relays can be closely mounted right side up as
shown in the following illustration.
6.5 mm
Current flow:
5 A max.
More than two relays can be closely mounted upside down as
shown in the following illustration.
7.62 mm in the
upside-down
direction
Current flow:
2 A max.
1.12 mm
Note: The space between each relay required for heat radiation
may vary with operating conditions. Contact your OMRON
representative for details.
Socket Mounting Height
18.5 mm max.
When mounting the relay, insert it into the socket as vertically as
possible so that the relay terminals contact securely with the contact pins on the socket.
The P6D is flux-resistive. Do not wash the P6D with water.
Dismount the relay from the socket before soldering the socket to
a PCB.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K127-E1-02
In the interest of product improvement, specifications are subject to change without notice.
OMRON RELAY & DEVICES Corporation
C&C Power Relay Division
Marketing Department
1110 Sugi, Yamaga-City,
Kumamoto, 861-0596 Japan
Tel: (81)968-44-4160/Fax: (81)968-44-4107
4
Printed in Japan
1208