Datasheet G2RL-1-12VDC, G2RL-2-24VDC, G2RL-1-E-24VDC, G2RL-1-E-12VDC, G2RL-2-12VDC Specification

Page 1
G2RL
G2RL-@@@-@
——— —
123 4
1. Number of Poles
1: 1-pole 2: 2-pole
2. Contact Form
None : NO/NC
A: NO
4. Classification
None : Standard
E : High-capacity
Model Number Legend Application Examples
• Home appliances
• OA equipments
• Industrial machinery
3. Enclosure rating
None : Flux protection
4 : Fully sealed
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A 5 VDC
Note 2. Place your order in tube (20 pcs/tube) units.
Rated coil voltage
PCB Power Relay
Low Profile Power Relay with 15.7 mm height, ideal for incorporation in miniature equipments
• A wide variety of single pole, double pole and high-capacity type Relays are available.
• High sensitivity with power consumption of 400 mW.
• Offers high insulation with insulation distance above 8 mm and impulse withstand voltage of 10kV between coil and contacts.
• Satisfies ambient operating temperature requirement of 85°C.
• Standard model conforms to VDE standards.
RoHS Compliant
Ordering Information
G
2
R
L
Classification Contact form Terminal Shape Enclosure rating Model Rated coil voltage Minimum packing unit
SPST-NO (1a)
SPDT (1c)
Standard
DPST-NO (2a)
PCB terminals
DPDT (2c)
SPST-NO (1a)
High-capacity
SPDT (1c)
Flux protection G2RL-1A Fully sealed G2RL-1A4 Flux protection G2RL-1 Fully sealed G2RL-14 Flux protection G2RL-2A Fully sealed G2RL-2A4 Flux protection G2RL-2 Fully sealed G2RL-24 Flux protection G2RL-1A-E Fully sealed G2RL-1A4-E Flux protection G2RL-1-E Fully sealed G2RL-14-E
5 VDC 12 VDC 24 VDC 48 VDC
Ratings
Coil
Item
Rated current
Rated voltage % of rated voltage
5 VDC 80.0 62.5 12 VDC 33.3 360 24 VDC 16.7 1,440 48 VDC 8.96 5,358 Approx. 430
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
(mA)
Coil resistance
(Ω)
Contacts
Item Model G2RL-1A G2RL-1 G2RL-2A G2RL-2 G2RL-1A-E G2RL-1-E Contact type Single Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 12 A (See note) 8 A (70°C)/5 A (85°C) (See note) 16 A (See note) Max. switching voltage 440 VAC, 300 VDC Max. switching current 12 A 8 A 16 A Failure rate (P level) (reference value*)
* This value was measured at a switching frequency of 120 operations/min. Note: Contact your OMRON representative for the ratings on fully sealed models.
Classification General-purpose Models (resistive load) High-capacity Models (resistive load)
12 A at 250 VAC 12 A at 24 VDC (See note)
Must operate voltage
(V)
75% max. 10% min.
8 A at 250 VAC 8 A at 30 VDC (See note)
Must release voltage
40 mA at 24 VDC
(V)
Max. voltage
(V)
130%
(at 85°C)
16 A at 250 VAC 16 A at 24 VDC (See note)
20 pcs/tube
Power consumption
(mW)
Approx. 400
1
Page 2
G2RL PCB Power Relay
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1 0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive load
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1 0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive load
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1 0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive load
Maximum coil voltage (%)
Ambient temperature (°C)
250
200
150
100
50
0 10 20 30 40 50 60 70 80 90 100
180
130
85
100
90
80
70
60
50
40
30
20
10
Ambient temperature (°C)
0604020 80 100 120
Must operate/must release voltage
(percentage of rated voltage) (%)
Must operate voltage Must release voltage
max.
min.
X
max.
min.
X
Sample: G2RL-14-E 24 VDC Number of relays: 5 pcs
Characteristics
Item Number of poles 1-pole 2-pole 1-pole
Classification General-purpose Models High-capacity Models
Contact resistance *1 100 mΩ max. Operate (set) time 15 ms max. Release (reset) time 5 ms max.
Max. operating frequency
Mechanical 18,000 operation/hr
Electrical 1,800 operation/hr
Insulation resistance *2 1,000 MΩ min. (at 500 VDC)
Dielectric strength
Between coil and contacts Between contacts of the same polarity
Between contacts of different polarity
5,000 VAC, 50/60 Hz for 1min
1,000 VAC, 50/60 Hz for 1min
2,500 VAC, 50/60 Hz for 1min
Impulse withstand voltage 10 kV (1.2 x 50 μs) Vibration
resistance
Shock resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Destruction 1,000 m/s Malfunction Energized: 100m/s2, De-energized: 100m/s
2
2
Mechanical 20,000,000 operations (at 18,000 operations/hr)
Durability
Electrical *3 (resistive load)
G2RL-1(A): 50,000 operations at 250 VAC, 12 A
30,000 operations at 24 VDC, 12 A
G2RL-2(A): 30,000 operations at 250 VAC, 8 A
30,000 operations at 30 VDC, 8 A
G2RL-1(A)-E: 30,000 operations at 250 VAC, 16 A
Ambient operating temperature -40°C to 85°C (with no icing or condensation) Ambient operating humidity 5% to 85% (with no icing or condersation)
G
Weight Approx. 12 g
2
Note. Values in the above table are the initial values.
R
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
L
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter. *3. 1,800 operations per hour.
30,000 operations at 24 VDC, 16 A
Engineering Data
Maximum Switching Capacity
G2RL-1A, G2RL-1 G2RL-1A-E, G2RL-1-E G2RL-2A, G2RL-2
Ambient Temperature vs.
Maximum Coil Voltage
Ambient Temperature vs. Must Operate and Must Release Voltages
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating power voltage, not a continuous voltage.
2
Page 3
G2RL PCB Power Relay
Z Z'
Shock direction
Y
Y'
XX'
Z'
Z
Y
Y'
X'
X
1,000
1,000
1,000
1,0001,000
1,000
NC contact
130
NO contact
Unit: m/s
2
G2RL-1 (A)-E G2RL-2 (A)
Sample: G2RL-14 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energ izing the Relays to check the number of malfunctions. Requirement: None malfuction 100 m/s
2
Sample: G2RL-24 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: None malfuction 100 m/s
2
1
4
3
5
(2.5)
15.7 max. (15.5)*
3.5
0.5
0.50.5 0.8
29 max.
(28.8)*
12.7 max. (12.5)*
Four, 1 .3-dia. holes
3.5
7.5
(2.3)20
* Average value
G2RL-1A, G2RL-1A4
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/ Internal Connections
(Bottom View)
15.7 max. (15.5)*
3.5
0.5
0.5
0.5 0.8
0.5
29 max.
(28.8)*
12.7 max. (12.5)*
3.5
Five, 1.3-dia. holes
(2.5) 1 243
5
3.5
7.5
(2.3)20
* Average value
G2RL-1, G2RL-14
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/ Internal Connections
(Bottom View)
1 364
58
(2.5)
15.7 max. (15.5)*
3.5
0.5
0.8
29 max.
(28.8)*
12.7 max. (12.5)*
Six, 1.3-dia. holes
5
7.5
(2.3)20
* Average value
0.50.5
G2RL-1A-E, G2RL-1A4-E
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/ Internal Connections
(Bottom View)
12364
758
(2.5)
15.7 max. (15.5)*
3.5
0.5
0.5
0.5 0.8
0.5
29 max.
(28.8)*
12.7 max. (12.5)*
5
Eight, 1.3-dia. holes
5
7.5
(2.3)20
* Average value
G2RL-1-E, G2RL-14-E
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/ Internal Connections
(Bottom View)
Shock Malfunction
Y
NO contact
1,000
Dimensions (Unit: mm)
1,000
X'
150
NC contact
Z'
1,000
Y'
Unit: m/s
Z
1,0001,000
1,000
X
2
Shock direction XX'
Y
Y'
Z Z'
G
2
R
L
3
Page 4
G2RL PCB Power Relay
G2RL-2A, G2R-2A4
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/ Internal Connections
(Bottom View)
12364
758
(2.5)
15.7 max. (15.5)*
3.5
0.5
0.5
0.5 0.8
0.5
29 max.
(28.8)*
12.7 max. (12.5)*
5
Eight, 1.3-dia. holes
5
7.5
(2.3)20
* Average value
G2RL-2, G2R-24
PCB Mounting Holes
(Bottom View)
(No coil polarity)
Terminal Arrangement/ Internal Connections
(Bottom View)
5
12.7 max.
0.50.5
* Average value
(12.5)*
7.5
(2.3)20
0.8
15.7 max. (15.5)*
3.5
29 max.
(28.8)*
0.5
Approved Standards
G
2
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm
R
the values before use.
L
UL Recognized: (File No. 41643)
CSA Certified: (File No. LR31928)
Model Contact form Coil ratings Contact ratings
G2RL-1A SPST-NO (1a) G2RL-1 SPDT (1c) 12 A, 24 VDC (Resistive) 40°C 50,000 G2RL-1A-E SPST-NO (1a) 16 A, 250 VAC (General Use) 40°C 100,000 G2RL-1-E SPDT (1c) 16 A, 24 VDC (Resistive) 40°C 50,000 G2RL-2A DPST-NO (2a) G2RL-2 DPDT (2c)
3 to 48 VDC
12 A, 250 VAC (General Use) 40°C 100,000
8 A, 277 VAC (General Use) 40°C 8 A, 30 VDC (Resistive) 40°C
Number of test
operations
100,000
Six, 1.3-dia. holes
(2.5)
1 364
58
EN/IEC, VDE Certified (Registration No. 119650)
Model Contact form Coil ratings Contact ratings
G2RL-1A SPST-NO (1a)
G2RL-1 SPDT (1c)
G2RL-1A-E SPST-NO (1a)
G2RL-1-E SPDT (1c)
G2RL-2A DPST-NO (2a)
G2RL-2 DPDT (2c)
Precautions
• Please refer to “PCB Relays Common Precautions” for correct use.
Mounting Position Compared to G2R Model
• Although the G2RL model and the G2R model are both low profile Relays, their characteristics such as switching capacity are different. Be sure to check operation under the actual operating conditions before use.
4
5, 12, 18, 22, 24, 48 VDC
Correct Use
Number of test
12 A, 250 VAC (cos 12 A, 24 VDC (L/R=0 ms) 85°C AC15: 3 A at 240 VAC at room temperature DC13: 2.5 A at 24 VDC, 50ms at room temperature
16 A, 250 VAC (cos 16 A, 24 VDC (L/R=0 ms) 85°C 15,000 AC15: 3 A at 240 VAC (NO) at room temperature,
1.5 A at 240V AC (NC) at room temperature DC13: 2.5 A at 24 VDC (NO), 50ms at room temperature 8 A, 250 VAC (cos
8 A, 24 VDC (L/R=0 ms) 85°C 15,000 AC15: 1.5 A at 240VAC at room temperature
DC13: 2 A at 30 VDC, 50ms at room temperature
φ
=1) 85°C
φ
=1) 85°C 30,000
φ
=1) 85°C 30,000
operations
Cleaning
• The G2RL model is flux-resistant with two sealing holes on the case. Thus, do not clean the Relay by boiling or soaking in water. Consult your Omron sales representative for sealed type Relay.
Using Relays in an Atmosphere Containing Corrosive Gas
• Do not use Relays in an atmosphere containing corrosive gas (sulfuric or organic gas).Otherwise, connection failure due to corrosion on the contact surface may lead to functional faults.
100,000
6,000
6,000
6,000
Page 5
G2RL PCB Power Relay
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation sys
tems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be
sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J117-E1-06
0812(0207)(O)
Note: Do not use this document to operate the Unit.