16 A at 250 VAC (General use), 100k ops.
16 A at 24 VDC (Resistive), 50k ops.
20Aat 240
15 A at 240 VAC (General use), 105_C
1/2 hp, 120 VAC, 100k ops., 70_C(NO)
8 A at 277 VAC (General use), 100k ops.
8 A at 30 VDC (Resistive), 100k ops.
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
16 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13: 2.5 A at 24 VDC (NO), 50 ms
8 A at 24 VDC (L/R=0 ms)
AC15: 1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
C (General use), 85_C
_
Note: To achieve approved life cycles on sealed models, the relay should be vented by removing “knock off vent nib” on top of relay case
after the soldering/washing process.
Electrical Life Data
Part numberContact ratingMinimum operations
G2RL-1-E
G2RL-1
G2RL-2
G2RL-1A-E
Note: 1. The results shown reflect minimum cycles using a very severe duty cycle of 1 sec ON/1 sec OFF (unless otherwise specified
above).
2. In order to obtain the full rated life cycles on the fully sealed models, the relay should be properly vented by removing the
“knock off vent nib” on top of the relay case after the soldering / washing process of the P.C.B.
Contact Omron for applications where venting of the sealed relay is not possible.
16 A at 250 VAC (cosφ=1)100,000 operations min. (1 sec. ON / 9 sec. OFF)
16 A at 24 VDC30,000 operations min.
8 A at 250 VAC (cosφ=0.4)200,000 operations min. (N.O. side operation)
8 A at 30 VDC (L/R=7 ms)10,000 operations min.
12 A at 250 VAC (cosφ=1)100,000 operations min. (1 sec. ON / 9 sec. OFF)
12 A at 24 VDC30,000 operations min.
5 A at 250 VAC (cosφ=0.4)150,000 operations min.
5 A at 30 VDC (L/R=7 ms)20,000 operations min.
8 A at 250 VAC (cosφ=1)100,000 operations min. (1 sec. ON / 9 sec. OFF)
8 A at 30 VDC30,000 operations min.
Pilot duty (A300), 250 VAC250,000 operations min. (1 sec. ON / 9 sec OFF)
Pilot duty (A300), 125 VAC150,000 operations min. (1 sec. ON / 9 sec OFF)
3
PCB Relay G2RL
Page 4
EngineeringData
J MAXIMUM SWITCHING CAPACITY
G2RL-1A, G2RL-1G2RL-1A-E, G2RL-1-EG2RL-2A, G2RL-2
AC resistive load
DC resistive
load
Switching current (A)
Switching voltage (V)
J AMBIENT TEMPERATURE
VS RATED CARRY CURRENT
G2RL-1A-E, G2RL-1-E
G2RL-1A, G2RL-1
AC resistive load
DC resistive
load
Switching current (A)
Switching voltage (V)
J AMBIENT TEMPERATURE
VS MAXIMUM COIL VOLTAGE
Switching current (A)
AC resistive load
DC resistive
load
Switching voltage (V)
G2RL-2A, G2RL-2
Rated carry current (A)
Ambient Temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.