Datasheet G2RL-1-24VDC Specification

Page 1
A Power Relay with Various Models
High-sensitivity (250 mW) and High-capacity
(16 A) Models available.
Low profile: 15.7 mm max. in height
Conforms to VDE (EN61810-1), UL508 and
CSA22.2.
products.
Clearance and creepage distance: 10 mm/10 mm.
Tracking resistance: CTI>250
Coil Insulation system: Class F (UL1446)
RoHS Compliant
Ordering Information
G2RL PCB Relay
Classification Enclosure
General-purpose Flux protection G2RL-1A G2RL-1 G2RL-2A G2RL-2
High-capacity Flux protection G2RL-1A-E G2RL-1-E --- ---
High-sensitivity Flux protection G2RL-1A-H G2RL-1-H --- ---
Note: When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A 12 VDC
ratings
Fully sealed G2RL-1A4 G2RL-14 G2RL-2A4 G2RL-24
Fully sealed G2RL-1A4-E G2RL-14-E --- ---
Rated coil voltage
SPST-NO SPDT DPST-NO DPDT
Contact form
Model Number Legend
G2RL-@@@-@
1 23 4
1. Number of Poles
1: 1 pole 2: 2 poles
2. Contact Form
None: @PDT A: @PST-NO
3. Enclosure Ratings
None: Flux protection 4: Fully sealed
4. Classification
None: General purpose E: High capacity (1 pole) H: High sensitivity (1 pole)
Specifications
Coils Ratings for General-purpose and High-capacity Models
Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC
Rated current 80.0 mA 33.3 mA 16.7 mA 8.96 mA
Coil resistance 62.5 360 1,440 5,358
Must operate voltage 70% max. of the rated voltage
Must release voltage 10% min. of the rated voltage
Max. voltage 180% of rated voltage (at 23°C)
Power consumption Approx. 400 mW Approx. 430 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
1
Page 2
Coils Ratings for High-sensitivity Models
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 50.0 mA 20.8 mA 10.42 mA
Coil resistance 100 576 2,304
Must operate voltage 75% max. of the rated voltage
Must release voltage 10% min. of the rated voltage
Max. voltage 180% of rated voltage (at 23°C)
Power consumption Approx. 250 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Contact Ratings
Item General-purpose Models High-capacity Models High-sensitivity Models
Number of poles 1 pole 2 poles 1 pole 1 pole
Contact material Ag Alloy (Cd free)
Load Resistive load (cosφ=1)
Rated load 12 A at 250 VAC
Rated carry current 12 A (See note.) 8 A (70°C)/5 A (85°C)
Max. switching voltage 440 VAC, 300 VDC
Max. switching current 12 A 8 A 16 A 10 A
Max. switching power 3,000 VA 2,000 VA 4,000 VA 2,500 VA
Note: Contact your OMRON representative for the ratings on fully sealed models.
Characteristics
Item General-purpose
Number of poles 1 pole 2 pole 1 pole
Contact resistance 100 m max.
Operate (set) time 15 ms max.
Release (reset) time 5 ms max.
Max. operating frequency Mechanical:18,000 operation/hr
Insulation resistance 1,000 M min. (at 500 VDC)
Dielectric strength 5,000 VAC, 1 min between coil and
Impulse withstand voltage 10 kV (1.2×50 µs) between coil and contact
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 1,000 m/s
Endurance (Mechanical) 20,000,000 operations (at 18,000 operations/hr)
Ambient temperature Operating: –40°C to 85°C (with no icing)
Ambient humidity 5% to 85%
Weight Approx. 12 g
Note: Values in the above table are the initial values.
Approved Standards
12 A at 24 VDC (See note.)
(High-capacity) Models
Electrical:1,800 operation/hr at rated load
contacts 1,000 VAC, 1 min between con­tacts of same polarity
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 100 m/s
Storage: –40°C to 85°C (with no icing)
8 A at 250 VAC 8 A at 30 VDC (See note.)
(See note.)
General-purpose Models High-sensitivity Models
5,000 VAC, 1 min between coil and contacts 2,500 VAC, 1 min between contacts of different polarity 1,000 VAC, 1 min between contacts of same polarity
2
(approx. 100 G)
2
(approx. 10 G)
16 A at 250 VAC 16 A at 24 VDC (See note.)
16 A (See note.) 10 A (See note.)
10 A at 250 VAC 10 A at 24 VDC (See note.)
5,000 VAC, 1 min between coil and contacts 1,000 VAC, 1 min between con­tacts of same polarity
UL508 (File No. E41643)/CSA C22.2 (No. 14) (File No. LR31928)
Model Contact form Coil ratings Contact ratings
G2RL-1A SPST-NO 3 to 48 VDC 12 A at 250 VAC (General use)
G2RL-1 SPDT
G2RL-1A-E SPST-NO 16 A at 250 VAC (General use)
G2RL-1-E SPDT
G2RL-1A-H SPST-NO 5 to 24 VDC 10 A at 250 VAC (General use)
G2RL-1-H SPDT
G2RL-2A DPST-NO 3 to 48 VDC 8 A at 277 VAC (General use)
G2RL-2 DPDT
12 A at 24 VDC (Resistive)
16 A at 24 VDC (Resistive)
10 A at 24 VDC (Resistive)
8 A at 30 VDC (Resistive)
G2RLG2RL
2
Page 3
VDE (EN61810-1) (License No. 119650)
Model Contact form Coil ratings Contact ratings
G2RL-1(A) 1 pole 5, 12, 18, 22, 24, 48 VDC 12 A at 250 VAC (cosφ=1)
G2RL-1(A)-E 1 pole 5, 12, 18, 22, 24, 48 VDC 16 A at 250 VAC (cosφ=1)
G2RL-1(A)-H 1 pole 5, 9, 12, 24 VDC 10 A at 250 VAC (cosφ=1)
G2RL-2(A) 2 poles 5, 12, 18, 22, 24, 48 VDC 8 A at 250 VAC (cosφ=1)
12 A at 24 VDC (L/R=0 ms) AC15: 3 A at 240 VAC DC13: 2.5 A at 24 VDC, 50 ms
16 A at 24 VDC (L/R=0 ms) AC15: 3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13: 2.5 A at 24 VDC (NO), 50 ms
10 A at 24 VDC (L/R=0 ms)
8 A at 24 VDC (L/R=0 ms) AC15: 1.5 A at 240 VAC DC13: 2 A at 30 VDC, 50 ms
Engineering Data
Maximum Switching Capacity
G2RL-1A, G2RL-1
50
10
5
Switching current (A)
1
0.5
AC resistive load
DC resistive load
Switching current (A)
G2RL-1A-E, G2RL-1-E
50
10
5
1
0.5
AC resistive load
DC resistive load
G2RL-2A, G2RL-2
50
10
5
Switching current (A)
1
0.5
AC resistive load
DC resistive load
G2RLG2RL
0.1 0 5 10 20 30 50 100 500
Switching voltage (V)
G2RL-1A-H, G2RL-1-H
AC resistive load
DC resistive
Switching current (A)
load
Switching voltage (V)
Ambient Temperature vs Must Operate and
Must Release Voltages
100
Sample: G2RL-14-E 24 VDC Quantity: 5
90
80
70
60
50
40
30
20
(percentage of rated voltage) (%)
10
Must operate/must release voltage
0604020 80 100 120
Ambient temperature (°C)
Must operate voltage Must release voltage
max.
min.
max.
min.
1,000
0.1 0 5 10 20 30 50 100 500
1,000
Switching voltage (V)
Ambient Temperature vs Maximum Coil Voltage
250
200
180
150
130
100
Maximum coil voltage (%)
50
0 10 20 30 40 50 60 70 80 90 100
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power voltage, not a continuous voltage.
85
0.1 0 5 10 20 30 50 100 500
Switching voltage (V)
Ambient Temperature vs Rated Carry Current
G2RL-1A-E, G2RL-1-E
G2RL-1A, G2RL-1
G2RL-1A-H, G2RL-1-H
Rated carry current (A)
G2RL-2A, G2RL-2
Ambient temperature (°C)
1,000
3
Page 4
Shock Malfunction
G2RL-1 (A)-E
Y
NO contact
X'
1,000
130
Sample: G2RL-14 DC12V Number of Relays: 5pcs
Z
Conditions: Shock is applied in ±X,±Y,±Z
1,0001,000
directions three times each with and without energizing the Relays to check the number of malfunctions. Requirement: None malfunction 100m/s
2
G2RL-2 (A)
NO contact
X'
150
Y
1,000
Sample: G2RL-24 DC12V Number of Relays: 5pcs
Z
Conditions: Shock is applied in ±X,±Y,±Z
1,0001,000
directions three times each with and without energizing the Relays to check the number of malfunctions. Requirement: None malfunction 100m/s
G2RLG2RL
2
Unit: m/s
2
1,000
X
Shock direction
XX'
Y
Y'
1,000
1,000
NC contact
Z'
1,000
Y'
Unit: m/s
2
1,000
X
Shock direction
XX'
Y
Y'
Z
Z'
NC contact
Z'
1,000
Y'
Electrical Endurance Data
G2RL-1-E 16 A at 250 VAC (cosφ=1) 30,000 operations min.
G2RL-1 12 A at 250 VAC (cosφ=1) 50,000 operations min.
G2RL-1-H 10 A at 250 VAC (cosφ=1) 100,000 operations min.
G2RL-2 8 A at 250 VAC (cosφ=1) 30,000 operations min.
Note: The results shown reflect values measured using very severe test conditions i.e., Duty: 1 s ON/1 s OFF.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information for the electrical endurance under your test conditions.
16 A at 24 VDC 30,000 operations min. 8 A at 250 VAC (cosφ=0.4) 200,000 operation min. (normally open side operation) 8 A at 30 VDC (L/R=7 ms) 10,000 operation min. (normally open side operation)
12 A at 24 VDC 30,000 operations min. 5 A at 250 VAC (cosφ=0.4) 150,000 operation min. (normally open side operation) 5 A at 30 VDC (L/R=7 ms) 20,000 operation min. (normally open side operation)
10 A at 24 VDC 50,000 operations min.
8 A at 30 VDC 30,000 operations min.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G2RL-1A(-H), G2RL-1A4
15.7 max. (15.5)*
G2RL-1(-H), G2RL-14
15.7 max. (15.5)*
G2RL-1A-E, G2RL-1A4-E
15.7 max. (15.5)*
3.5
3.5
Terminal Arrangement/ Internal Connection (Bottom View)
1
5
* Indicates average dimensions.
0.8
3
4
0.5
29 max. (28.8)*
0.5
0.5
12.7 max. (12.5)*
Terminal Arrangement/
29 max. (28.8)*
3.5
0.5
0.5
12.7 max. (12.5)*
0.5
0.5
Internal Connection (Bottom View)
1
* Indicates average dimensions.
0.8
2
3
45
Terminal Arrangement/ Internal Connection (Bottom View)
1
8
* Indicates average dimensions.
0.8
453
6
0.5
29 max. (28.8)*
0.5
0.5
12.7 max. (12.5)*
Mounting Holes (Bottom View)
7.5
(2.3)
Mounting Holes (Bottom View)
7.5
(2.3)
Mounting Holes (Bottom View)
7.5
(2.3)
Four, 1.3±0.1 dia.
3.5
holes
(2.5)
20
Five, 1.3±0.1 dia.
3.5 3.5
holes
(2.5)
20
Six, 1.3±0.1 dia. holes
5
(2.5)
20
Z
Z'
4
Page 5
G2RLG2RL
G2RL-1-E, G2RL-14-E
G2RL-2A, G2RL-2A4
G2RL-2, G2RL-24
15.7 max. (15.5)*
3.5
15.7 max. (15.5)*
3.5
15.7 max. (15.5)*
3.5
0.5
0.5
0.5
29 max. (28.8)*
0.5
29 max. (28.8)*
0.5
29 max. (28.8)*
0.5
0.5
0.5
0.5
0.5
0.5
12.7 max. (12.5)*
12.7 max. (12.5)*
12.7 max. (12.5)*
Terminal Arrangement/ Internal Connection (Bottom View)
1
0.8
* Indicates average dimensions.
2
8
7
Terminal Arrangement/ Internal Connection (Bottom View)
1
8
0.8
* Indicates average dimensions.
Terminal Arrangement/ Internal Connection (Bottom View)
1
8
* Indicates average dimensions.
0.8
2
7
Mounting Holes (Bottom View)
4
3
6
7.5
5
(2.3)
20
5
5
Eight, 1.3±0.1 dia. holes
(2.5)
Mounting Holes (Bottom View)
4
3
5
6
7.5
(2.3)
20
Mounting Holes (Bottom View)
4
3
5
6
7.5
(2.3)
55
20
5
Six, 1.3 holes
(2.5)
Eight, 1.3 holes
(2.5)
±0.1 dia.
±0.1 dia.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. X033-E1-14A
In the interest of product improvement, specifications are subject to change without notice.
Loading...