For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
G2R - -
1234 5
S(S)
Whenyourorder,specifytheratedvoltage.
When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
Example: G2R-1-S 12 VDC
(S)
Rated coil voltage
G2R-@-S (S)
Slim and Space-saving Power Plug-in Relay
■ Reduces wiring work by 60% when combined with the
P2RF-@-PU Push-In Plus Socket
(according to actual OMRON measurements).
■ Lockable test button models available.
■ Built-in mechanical operation indicator.
■ Provided with nameplate.
■ AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
■ High switching power (1-pole: 10 A).
CSM_G2R-_-S_(S)_DS_E_1_3
Model Number Structure
Model Number Legend
1. Number of Poles
1:1 pole
2:2 poles
2. Terminals
S:Plug-in
3. Classification
Blank: General-purpose
N:LED indicator
D:Diode
ND:LED indicator and diode
NI:LED indicator with test button
NDI: LED indicator and diode with test button
Note: Contact your OMRON representative for Relays with gold-plated contacts.
4. Rated Coil Voltage
5. Mechanical operation indicator and Nameplate
(S):Models with mechanical operation indicator and Nameplate
Ordering Information
List of Models
Classification
General-purpose
LED indicatorG2R-1-SN (S)G2R-2-SN (S)
LED indicator with test buttonG2R-1-SNI (S)G2R-2-SNI (S)
Diode
LED indicator and diodeG2R-1-SND (S)G2R-2-SND (S)
LED indicator and diode with test buttonG2R-1-SNDI (S)G2R-2-SNDI (S)
Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combina-
tions with the P2RF-@-E, P2RF-@-S and P2RF-@-PU. The Relays bear the CE Marking.
2. Refer to Connecting Sockets, below, for applicable Socket models.
* The structure of P2RF-@-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
Accessories for Push-In Plus Terminal Block Sockets (P2RF-@-PU)
Short Bars
PitchNo. of polesColorsModel *Minimum order (quantity)
2
7.75 mm
15.5 mm8PYDN-15.5-080@
Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.
* Replace the box (@) in the model number with the code for the covering color.
Labels
Model
XW5Z-P4.0LB1
3PYDN-7.75-030@
4PYDN-7.75-040@
20PYDN-7.75-200@
Minimum order (sheet)
(quantity per sheet)
1 sheet (60 pieces)
Push-In Plus
Terminal Blocks
Red (R)
Blue (S)
Yellow (Y)
5
P2RF-05
P2RF-05-E
P2RF-08
P2RF-08-E
PYDN-7.75-020@
Screw terminals *PCB terminalsSolder terminals
P2R-05P
P2R-057P
P2R-08P
P2R-087P
10
P2R-05A
P2R-08A
Mounting Tracks
Applicable SocketDescriptionModel
50 cm (l) × 7.3 mm (t): PFP-50N
Mounting track
Track-connecting Socket
End plate *1PFP-M
SpacerPFP-S
Back-connecting Socket Mounting plate *2P2R-P
*1. When mounting DIN rail, please use End Plate (PFP-M).
*2. Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
1 m (l) × 7.3 mm (t):PFP-100N
1 m (l) × 16 mm (t):PFP-100N2
Minimum order
(quantity)
---
10
1
2
Page 3
Specifications
Coil Ratings
Rated current*
Rated voltage
50 Hz60 Hz
24 V43.5 mA37.4 mA253 Ω0.811.55
110 V9.5 mA8.2 mA5,566 Ω13.3326.83
AC
120 V8.6 mA7.5 mA7,286 Ω16.1332.46
230 V4.4 mA3.8 mA27,172 Ω72.68143.90
240 V4.2 mA3.7 mA27,800 Ω90.58182.34
Coil
resistance
Coil inductance (H)
Armature
OFF
(ref. value)
Armature
ON
G2R-@-S (S)
Must
operate
voltage
80% max.30% max.110%0.9 VA at 60 Hz
Must
release
voltage
% of rated voltage
Max.
voltage
Power
consumption
(approx.)
Coil inductance (H)
Rated voltageRated current*
6 V87.0 mA69 Ω0.250.48
12 V43.2 mA278 Ω0.982.35
DC
24 V21.6 mA1,113 Ω3.608.25
48 V11.4 mA4,220 Ω15.229.82
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current
and ±10% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil.
It is not the maximum voltage that can be applied continuously.
contacts;
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
Vibration resistance
Shock resistance
Destruction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction:1,000 m/s
2
Malfunction:200 m/s2 when energized; 100 m/s2 when not energized
Mechanical:AC coil: 10,000,000 operations min.;
Endurance
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperatureOperating:–40°C to 70°C (with no icing or condensation)
Ambient humidityOperating: 5% to 85%
WeightApprox. 20 g
Note: Values in the above table are the initial values.
* These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets.
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
5,000 VAC, 50/60 Hz for 1 min between coil and contacts;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Approved Standards
UL 508 (File No. E41643)
Model
G2R-1-S (S) SPDT
G2R-2-S (S) DPDT
CSA 22.2 No.0, No.14
(File No. LR31928)
Model
G2R-1-S (S) SPDT
G2R-2-S (S) DPDT
Contact
form
Contact
form
Coil ratingsContact ratings
5 to 110 VDC
6 to 240 VAC
Coil ratingsContact ratings
5 to 110 VDC
6 to 240 VAC
Opera-
tions
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)25 × 10
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)25 × 10
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)25 × 10
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)25 × 10
100 × 10
100 × 10
Opera-
tions
100 × 10
100 × 10
IEC/VDE (Certificate No. 40015012 EN 61810-1)
Contact
form
3
3
3
3
1 pole
2 poles
Coil ratingsContact ratingsOperations
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
100 × 10
100 × 10
3
3
LR
Number
of poles
3
3
3
3
1 pole
2 poles
Coil ratingsContact ratingsOperations
5 to 110 VDC
6 to 240 VDC
5 to 110 VDC
6 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
100 × 10
100 × 10
3
3
4
Page 5
Engineering Data
100
10
1
0.1
1101001000
100
10
1
0.1
1101001000
G2R-1-S (S)
Switching current (A)
Switching voltage (V)
G2R-2-S (S)
Switching voltage (V)
Switching current (A)
AC inductive load
(cosφ = 0.4)
AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
AC inductive load
(cosφ = 0.4)
AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
5,000
1,000
500
100
50
5,000
1,000
500
100
50
10,000
G2R-1-S (S)
Endurance (x10
3
operations)
Switching current (A)
G2R-2-S (S)
Switching current (A)
30-VDC inductive load (L/R = 7ms)
30-VDC inductive load (L/R = 7ms)
Endurance (x10
3
operations)
250-VAC/30-VDC
resistive load
250-VAC inductive load
(cosφ = 0.4)
250-VAC/30-VDC
resistive load
250-VAC
inductive load
(cosφ = 0.4)
Ambient temperature (°C)
Maximum voltage (%)
DC coil
AC coil
Maximum Switching Power
Endurance
G2R-@-S (S)
Ambient Temperature vs Maximum Coil Voltage
5
Page 6
G2R-@-S (S)
G2R-1-S (S), G2R-1-SN (S), G2R-1-SNI (S)
G2R-1-SD (S), G2R-1-SND (S), G2R-1-SNDI (S)
G2R-2-SN (S), G2R-2-SNI (S) (AC)G2R-2-SN (S), G2R-2-SNI (S) (DC)
20
0.5
55
2.5
2.4
19.4
29 max.
35.5 max.
13 max.
6.2
7.4
8.9
1
8
234
765
234
567
1
8
234
765
1
8
234
765
1
8
1
8
234
765
Dimensions(Unit: mm)
Note: All units are in millimeters unless otherwise indicated.
SPDT Relays
DPDT Relays
6
Page 7
Track/Surface Mounting Sockets
Mounting Hole
Dimensions
52.4
45
36.3
27.6
27.25
35.5
28.1
27.6
52.1
3.9
56.5 max.
15.5 max.
90 max.
(3)
(3)
Releaselever
14
12
11
A1A2
Terminal Arrangement/
Internal Connection Diagram
(Top View)
(5)
(2)
(4)
(3)
(1)
Two M4 screw
holes or
two 4-dia. holes
108
P2RF-05-PU
Note: Pull out the hooks to
mount the Relay
with screws.
Note: The numbers in
parentheses are
traditionally used
terminal numbers.
Mounting Hole
Dimensions
27.6
28.1
45
36.3
27.6
35.5
27.25
52.1
52.4
3.9
56.5 max.
15.5 max.
(3)
(3)
90 max.
Releaselever
142224
21
12
11
A1A2
Terminal Arrangement/
Internal Connection Diagram
(Top View)
(8)
(2)
(4)
(3)
(7)
(5)
(6)
(1)
Two M4 screw
holes or
two 4-dia. holes
108
P2RF-08-PU
Note: Pull out the hooks to
mount the Relay
with screws.
Note: The numbers in
parentheses are
traditionally used
terminal numbers.
Accessories for P2RF-@-PU
Short Bars
PYDN-7.75-@@ (7.75 mm)
PYDN-15.5-080@ (15.5 mm)
3.90
L
1.572.25
12
18.5
3.90
1.57
2.25
12
18.5
115.85
* Replace the box (@) in the model number with the code for the covering color.
Note: 1. Use the Short Bars for crossover wiring within one Socket or between Sockets.
2. When using short bar to coil terminals of P2RF-@@-PU, A1 terminal cannot be used.
In case crossover wiring of A1 terminal side is needed, crossover wiring using A1
terminals by wire is possible.
Short bar correspondence table
ApplicationPitch
No. of
poles
L (Length)ColorsModel
*
Maximum
carry current
For Contact
terminals
(common)
7.75 mm
215.1
Red (R)
Blue (S)
Yellow (Y)
PYDN-7.75-020@
20 A
322.85PYDN-7.75-030@
430.6PYDN-7.75-040@
20154.6PYDN-7.75-200@
For Coil
terminals
15.5 mm8115.85PYDN-15.5-080@
Contact terminal
(Common)
Coil terminal
A1A2
P2RF-@@-PUAvailable---❍
G2R-@-S (S)
7
Page 8
G2R-@-S (S)
39.5±0.1
P2RF-05
P2RF-08
7
4
2
35.5
19.5
30±0.05
7
4
2
35.5
19.5
30±0.05
P2RF-05-E
39.5
35.5
11.5
(11)
(14)
(12)
(A1)
(A2)
1
2
3
4
5
39.5±0.1
2
1.5
4
2
3
39.5
35.5
11.5
P2RF-08-E
8
6 3
7
2
54
(A1)
(A2)
(21)
(22)
(24)
(11)
(12)
(14)
1
2
3.2-dia.
hole
Five, M3.5 x 8
19.5 max.
4-dia. holes
30 max.
54 max.
4.2-dia. hole
71.5 max.
19.5 max.
Eight, M3.5 x 8
4-dia. holes
30 max.
54 max.
4.2-dia. hole
3.2-dia.
hole
Five, M3.5´7
85.5 max.
16.0 max.
48 max.
Note: Pin numbers in parentheses apply to DIN standard.
61 max.
Eight, M3´8
3.5-dia. hole
16.0 max.
48.0 max.
61.0
max.
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
M3 or
3.5-dia.
hole
M3 or
3.5-dia.
hole
3.5-dia.
hole
85.5
max.
M3 or 3.2-dia.
hole
M3 or 3.2-dia.
hole
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
71.5 max.
4
7±0.2
6
+0.2
−0.1
8
Page 9
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-@P2RF-@-E
P2RF-05-PUP2RF-08-PU
G2R-@-S (S)
Relay
G2R-@-S (S)
Relay
P2RF-@-E
Socket
P2RF
Socket
66.5
62.0
67.0
70.5
G2R-@-S (S)
Relay
G2R-@-S (S)
Relay
63.6
28.1
(3.9)
63.6
28.1
(3.9)
1
47
6
4.5
15
4
3.5
1.2
1.5
7
4
4
6
4.5
15
4
7
4
7
0.3
5
5
20
1
2.8
1.5
7.5
7.5
5
5
20
(4.3)
(5)
P2R-05P (1-pole)
14.5 max.
35.5 max.
Tolerance: ±0.1
Mounting Holes
P2R-08P (2-pole)
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
Eight, 1.3-dia. holes
Terminal Arrangement
(Bottom View)
Mounting HolesTerminal Arrangement
(Bottom View)
Five,
1.6-dia.
holes
36.5 max.
G2R-@-S (S)
Back-connecting Sockets
9
Page 10
G2R-@-S (S)
4.5
1.2
0.3
6.7
3.8
16.7
5
6
1.2
0.3
5
5
20
2.8
2.6
7.5
13.6±0.1
30.5±0.2
1.5
7.5
7.56.5
P2R-05A (1-pole)
Panel Cutout
P2R-08A (2-pole)
Five, 3 x 1.8-dia. holes
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
Eight, 3 x 1.2-dia. holes
Terminal Arrangement
(Bottom View)
Recommended thickness of
the panel is 1.6 to 2.0 mm
P2R-057P (1-pole)
P2R-087P (2-pole)
4.5±0.1
15±0.1
4±0.1
5
4±0.1
6±0.1
7±0.1
7.5
5
5
20
(8.1)
29.6
0.7
8.9
8.7
8.7
29.1
7.5
14 max.
37 max.
14 max.
37 max.
41 max.
Mounting Holes
Terminal Arrangement
(Bottom View)
Mounting Holes
Terminal Arrangement
(Bottom View)
Eight,
1.3-dia.
holes
Five,
1.6-dia.
holes
7.4
1
0.3
16.4
1
10.4
3.5
5
20
8.1
5
16.4
1
10.4
1
1
7.4
41 max.
3.5
6
15
4
8.75
4.5
38.0
P2R-@7P
G2R-@-S (S) Relay
P2R-@P
Socket
P2R-@A
Socket
G2R-@-S (S) Relay
P2R-@7P
Socket
G2R-@-S (S) Relay
P2R-@PP2R-@A
47.5
44.5
Mounting Height of Relay with Back-connecting Sockets
10
Page 11
Mounting Tracks
PFP-100N, PFP-50NPFP-100N2
4.5
15 25
25
25
25
10
10
1,000 (500)
7.3±0.15
35±0.3
27±0.15
1
4.5
15 2525
25
25
15
10
10
1,000
35±0.3
27
24
16
29.2
11.5
15 (5)
It is recommended to use a panel 1.6 to 2.0 mm thick.
PFP-M
PFP-S
50
11.5
10
6.2
1.8
1
35.5 35.3
1.8
1.3
4.8
5
16
12
44.3
34.8
10
16.5
M4 x 8 pan
head screw
90
4.5
49
42
±0.1
9
±0.1
9
±0.1
18
±0.1518±0.1518±0.15
72
±0.2
18
±0.15
R2.25
10-Ellipsehole
13.6
Squarehole
3.4
30.5
t=1.6 mm
End PlateSpacer
G2R-@-S (S)
Mounting Plate
P2R-P
Safety Precautions
Be sure to read the Common Precautions for All Relay in the website at the following URL:
http://www.ia.omron.com/.
Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets.
@@
Refer to PYF-
Warning Indications
CAUTION
-PU/P2RF-@@-PU for precautions on Push-In Plus Terminal Block Sockets.
Indicates a potentially hazardous
situation which, if not avoided, may result
in minor or moderate injury or in property
damage.
Cation
• Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
• Check that the test button is released before turning ON relay cir-
cuits.
• If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
• Use an insulated tool when you operate the test button.
replacementthereof)thenon-complyingProduct,(ii)repairthenon-complyingProduct,or(iii)repayorcreditBuyeranamountequaltothepurchasepriceofthenon-complyingProduct;providedthatinnoeventshallOmronberesponsibleforwarranty, repair,indemnityoranyother claimsorexpensesregardingtheProductsunlessOmron’sanalysisconfirmsthattheProductswereproperlyhandled,stored,installedandmaintainedandnotsubjecttocontamination,abuse,misuseorinappropriatemodification. Return of any Productsby Buyer must be approved in writing by Omronbeforeshipment. Omron Companies shallnotbeliableforthesuitabilityorunsuitabilityortheresultsfromtheuseofProductsincombinationwithanyelectricalorelectroniccomponents,circuits,systemassembliesoranyothermaterialsorsubstancesorenvironments.Anyadvice,recommendationsorinformationgivenorallyorinwriting,arenottobeconstruedasanamendmentoradditiontotheabovewarranty.Seehttp://www.omron.com/global/orcontactyourOmronrepresentativeforpublishedinformation.
ChangeinSpecifications.Productspecificationsandaccessoriesmaybechangedatanytimebasedonimprovementsandotherreasons.Itisourpracticetochangepartnumberswhenpublishedratingsorfeaturesare changed,orwhensignificant construction changesaremade.However,somespecificationsoftheProductmaybechangedwithoutanynotice. Whenindoubt,specialpartnumbersmaybeassignedtofixorestablishkeyspecificationsforyourapplication.PleaseconsultwithyourOmron’srepresentativeatanytimetoconfirmactualspecificationsofpurchasedProduct.