The ‘ACT04 contain six independent inverters.
The devices perform the Boolean function Y = A
The SN54ACT04 is characterized for operation
over the full military temperature range of –55°C
to 125°C. The SN74ACT04 is characterized for
operation from –40°C to 85°C.
FUNCTION TABLE
(each inverter)
logic symbol
INPUT
AY
HL
LH
†
OUTPUT
SN54ACT04 ...J OR W PACKAGE
SN74ACT04 . . . D, DB, N, OR PW PACKAGE
.
SN54ACT04 . . . FK PACKAGE
2A
NC
2Y
NC
3A
NC – No internal connection
(TOP VIEW)
1A
1
1Y
2
2A
3
2Y
4
3A
5
3Y
6
GND
7
(TOP VIEW)
1Y1ANC
3212019
4
5
6
7
8
910111213
3Y
GND
14
13
12
11
10
NC
V
CC
6A
6Y
5A
5Y
4A
9
4Y
8
CC
V
6A
18
17
16
15
14
4Y
4A
logic diagram, each inverter (positive logic)
6Y
NC
5A
NC
5Y
1
1A
3
2A2Y
5
3A3Y
9
4A4Y
11
5A5Y
13
6A6Y
†
This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
Pin numbers shown are for the D, DB, J, N, PW, and W packages.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
2
4
6
8
10
12
1Y
YA
Copyright 1996, Texas Instruments Incorporated
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
1
Page 2
SN54ACT04, SN74ACT04
UNIT
HEX INVERTERS
SCAS518A – JULY 1995 – REVISED APRIL 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
Input voltage range, VI (see Note 1) –0.5 V to VCC + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, VO (see Note 1) –0.5 V to VCC + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
Output clamp current, I
Continuous output current, I
Continuous current through V
Maximum power dissipation at TA = 55°C (in still air) (see Note 2): D package 1.25 W. . . . . . . . . . . . . . . . . .
Storage temperature range, T
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
CC
= –50 µ
OH
OH
OL
I
I
I
CC
‡
∆I
CC
C
†
Not more than one output should be tested at a time, and the duration of the test should not exceed 2 ms.
‡
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
i
IOL = – 24 mA
IOH = – 50 mA
IOH = –75 mA
= 50 µ
OL
= 24
OL
IOL = 50 mA
IOL = 75 mA
VI = VCC or GND5.5 V±0.1±1±1µA
VI = VCC or GND,IO = 05.5 V24020µA
One input at 3.4 V ,
Other inputs at GND or V
VI = VCC or GND5 V4.5pF
†
†
†
†
CC
4.5 V4.44.494.44.4
5.5 V5.45.495.45.4
4.5 V3.863.73.76
5.5 V4.864.74.76
5.5 V3.85
5.5 V3.85
4.5 V0.0010.10.10.1
5.5 V0.0010.10.10.1
4.5 V0.360.50.44
5.5 V0.360.50.44
5.5 V1.65
5.5 V1.65
5.5 V0.61.61.5mA
TA = 25°CSN54ACT04SN74ACT04
MINTYPMAXMINMAXMINMAX
switching characteristics over recommended operating free-air temperature range,
V
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
CC
TA = 25°CSN54ACT04SN74ACT04
MINTYPMAXMINMAXMINMAX
168.51919
15.5818.518.5
t
PLH
t
PHL
FROMTO
(INPUT)(OUTPUT)
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETERTEST CONDITIONSTYPUNIT
C
pd
Power dissipation capacitanceCL = 50 pF,f = 1 MHz45pF
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
3
Page 4
SN54ACT04, SN74ACT04
HEX INVERTERS
SCAS518A – JULY 1995 – REVISED APRIL 1996
PARAMETER MEASUREMENT INFORMATION
TESTS1
t
PLH/tPHL
From Output
Under Test
CL = 50 pF
(see Note A)
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Open
500 Ω
500 Ω
Figure 1. Load Circuit and Voltage Waveforms
S1
2 × V
Open
CC
Input
(see Note B)
In-Phase
Output
Out-of-Phase
Output
1.5 V1.5 V
t
PLH
50% V
t
PHL
50% V
VOLTAGE WAVEFORMS
CC
CC
t
PHL
50% V
t
PLH
50% V
CC
CC
3 V
0 V
V
V
V
V
OH
OL
OH
OL
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
Page 5
IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty . Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICA TIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERST OOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.