EAN/UPC disable AA0
CODE SELECTION
EAN 8/EAN 13/UPC A/UPC E enable AA1
EAN 8/EAN 13 enable AA3
UPC A/UPC E enable AA4
EAN 8 enable AAG0
EAN 13 enable AAH0
UPC A enable AAI0
UPC E enable AAJ0
Code 39 disable AB0
Code 39 Standard enable AB11xxyy
Code 39Full ASCII enable AB21xxyy
Code 2/5 family disable AC0
Interleaved 2/5 enable AC11xxyy
Normal 2/5 5 bars enable AC21xxyy
Industrial 2/5 (IATA) enable AC31xxyy
Matrix 2/5 3 bars enable AC41xxyy
Codabar family disable AD0
Codabar standard enable AD111xxyy
Code 128 family disable AI0
Code 128 enable AI11 xxyy control without transmission of check digit
EAN 128 enable AI21 xxyy control without transmission of check digit
Code Length AILxxyy
Code 93 family disable AK0
Code 93 enable AK1 xxyy control without transmission of check digit
PDF417 disable AR0
PDF417 enable AR1
Pharmacode disable AQ0
Pharmacode enable AQ1xxyy
Overflow ratio AQAzz
xxyy = ASCII numbers that define:
xx = min. acceptable code length yy = max. acceptable code length zz = overflow ratio value
AA5
AA8
AAK
AAL
AA6
AAM
AAN
AA7
AAG1
AAH1
AAI1
AAJ1
AB12xxyy
AB13xxyy
AB22xxyy
AC12xxyy
AC13xxyy
AC22xxyy
AC23xxyy
AC32xxyy
AC33xxyy
AC42xxyy
AC43xxyy
AD112xxyy
AD121xxyy
AD122xxyy
AD212xxyy
AQ2xxyy
The minimum code length must always be less than or equal to the maximum.
For more detailed information on the TC1100 programmability and complete parameter list, please refer to the
TC1100 Reference Manual.
N24
without ADD ON
with ADD ON
with and without ADD ON
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
check digit transmission disable
check digit transmission enable
check digit transmission disable
check digit transmission enable
check digit transmission disable
check digit transmission enable
check digit transmission disable
check digit transmission enable
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
check digit control without transmission
no start/stop character equality control - nor transmission
no start/stop character equality control but transmission
start/stop character equality control but no transmission
start/stop character equality control and transmission
ABC Codabar no start/stop character equality control but transmission
forward code tx direction
reverse code tx direction
821000676 (Rev. H)
TC1100
CCD Scanner
Quick Reference Guide
The TC1100 is a linear CCD Scanner for OEM applications. It is available in two different versions:
Model Description Order Number
TC1100-1100 CCD scanner for linear codes 939501020
TC1100-1200 CCD scanner for linear and PDF417 939501030
Technical Specifications
Power supply
Consumption 1.5 W
Interfaces RS232, WEDGE, PEN Emulation
Max Scans/sec 270
Max resolution 0,076mm (3mils)
Readable codes:
Default Configuration
Power Save 270 scans/sec, sleep disabled, standby disabled
Reading Parameters On-Line
Code Selection
Enabled codes
(Only TC1100-1200)
Data Format Code ID disabled, Header = <STX>, Terminator = <CR> <LF>, no Field Adjustment, Code
Decoding Parameters
Enabled interface RS232, 9600, N, 8, 1, no handshaking, ACK/NAK disabled, RX timeout 100 ms, FIFO
Reading Diagrams
mm
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
160
140
120
100
80
0.20 mm
60
40
20
0
-20
-40
-60
-80
-100
-120
0.13 mm
-140
5 mils
-160
Reading Diagram TC1100-1100 (code 39) Reading Diagram TC1100-1200 (PDF417)
0.20 mm
5 Vdc ± 5%
EAN/UPC, Code 39, 2/5 family, Codabar, Code 128, EAN 128, ISBT 128, Code 93,
pharmaceutical codes, Delta IBM, Code 16K, Code 49, (Telepen, MSI/Plessey, Pharmacode
only TC1100-1100), (Codablock-A, Codablock-F Std, Codablock-F EAN, PDF417 only
TC1100-1200)
• Interleaved 2 of 5: Check Digit transmitted, length: min 4, max 99
• Code EAN8, EAN13, UPCA, UPCB: without ADD ON, Check Digit transmitted, no conversions
• Code 39: length: min 1, max 99
• Code 128: Check Digit not transmitted, length: min 1, max 99
• PDF417
length TX disabled, character replacement disabled, No Read Character = <CAN>
Ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver™
disabled, decoding safety = 1 read
enabled, inter-character delay disabled
mm
0 102030405060708090100110120130140150160170180
90
80
70
60
50
40
30
20
10
0
10
-
-20
-30
-40
-50
-60
-70
-80
-90
8 mils
0.30 mm
12 mils
0.50 mm
20 mils
0.17 mm
(6.6 mils)
0.25 mm
(10 mils)
0.38 mm
(15 mils)

Electrical Connections
1 Shield earth ground
2 TX transmit data
3 RX receive data
4 RTS request to send
5 CTS clear to send
6 nc not connected
7 SGND signal ground
8 EXT BEEPER external beeper connection
9 VCC+ +5Vdc
10 nc not connected
11 OUT+
12 OUT13 VCC+ +5Vdc
14 nc not connected
15 nc not connected
16 nc not connected
17 nc not connected
18 EXT TRIG+
19 EXT TRIG20 DATAIN_WAND
21 DATAOUT
22 OUT-
23 CLKIN
24 CLKOUT
25 GND power ground
25-pin connector
See Figure 1
See Figure 2
Led Status
POWER ON
GOOD READ
ON = Power ON
OFF = Power OFF
ON = Good Read
(the LED will rema in ON until status changes)
OFF = No Read
70.7
[2.78]
68.6
[2.70]
mm
[in.]
40 Vdc max
TC1100
USER INTERFACE
11
OUT +
12
OUT -
Vext
Figure 1 - Output Connection (Good Read). Example NPN
Return to RS232 Interface
Ì$+CP0$-$Î
For WEDGE Users
Physical Dimensions
Width 70.7 mm 2.78 inches
Length 68.6 mm 2.70 inches
Height 30.5 mm 1.20 inches
30.5
[1.20]
7.6
[0.30]
24
[0.94]
10.4
[0.41]
31.6
[1.25]
54
[2.13]
9.5
[0.37]
Optical Axis
17.7
[0.70]
Vext
18
19
EXT TRIG+
EXT TRIG-
30 Vdc max.
V
Signal
Ground
TC1100
+ 5V
18
19
Vext
EXT TRIG+
EXT TRIG-
30 Vdc max.
EXTERNAL TRIGGER
V
Signal
TC1100 EXTERNAL TRIGGER
+ 5V
Input NPN command using external power Input PNP command using external power
+ 5V
13
18
19
25
Vcc 5Vdc
EXT TRIG+
EXT TRIG-
GND
EXTERNAL TRIGGERTC1100
V
Ground
Signal
+ 5V
13
18
19
25
Vcc 5Vdc
EXT TRIG+
Input NPN command using TC1100 power Input PNP command using TC1100 power
Figure 2 - Trigger Connections
EXT TRIG-
GND
EXTERNAL TRIGGERTC1100
V
Signal
Ground
Basic Commands for TC1100
The TC1100 default configuration can be changed by receiving commands through the RS232
Interface. The command syntax is given below with an example.
Command syntax
$+ Command(s) $- <CR> the new setting will be definitive (stored in FLASH EPROM)
Example:
Enter configuration environment
Serial On-Line
Commands:
Operating Mode
Baud Rate = 19200
Multiple command programming sequence:
BK0 $- CR
$+
AC410132CD7
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
Carriage return character (0D Hex.)
Exit and save new configuration
OPERATING MODES
On-line BK1
Serial On-line BK0
Automatic BK3
Automatic / Lighting System Standby BK2
To enter in Test mode #+DStat1<CR> (does not require $+ or $-)
To exit Test mode #+DStat0<CR> (does not require $+ or $-)
GENERAL FEATURES
RS232 interface selection CP0
RS232 Baud Rate CD0 for 150 Baud up to CD8 for 38400 Baud
WEDGE AT CP500
WEDGE Notebook CP505
Keyboard Nationality FJ7 Belgian
CCD Scan Rate BT0 67 scans/sec
Puzzle Solver AU1 enable AU0 disable
Ink Spread AX1 enable AX0 disable
Decoding safety ED0 1 read
To restore the default configuration $+$*<CR> (does not require $-)
To get configuration from the scanner $+$&<CR> (does not require $-)
FJ4 English
FJ2 French
FJ3 German
BT1 135 scans/sec
BT2 270 scans/sec
ED1 2 reads
FJ1 Italian
FJ6 Spanish
FJ5 Swedish
FJ0 USA
ED2 3 reads
ED3 4 reads