Datalogic Scanning SH2347 User Manual

Special Instructions for
DS1100 SH2347 and DS2200 SH2348
10 - 30 Vdc
Electrical Connections
The scanner cable is equipped with a 25-pin female D-sub connector for connection with the power supply and input/output signals:
Pin Name Function
9,13 VS Power supply input voltage +
25 GND Power supply input voltage -
1 * CHASSIS Chassis Ground 2, 21 TXAUX TX RS232 Aux. Interface 3, 20 RXAUX RX RS232 Aux. Interface
4 RTX485 - RTX- RS485 Main Interface 5 RTX485 + RTX+ RS485 Main Interface 7 SGND Signal Ground
8 OUT1 + Output 1 + 11 OUT2 + Output 2 + 18 EXT TRIG + External trigger + 19 EXT TRIG - External trigger -
10, 12, 22 I/O REF Input/Output reference
17 IN1 - Input 1 -
6, 14, 15, 16, 23, 24 N.C. Not Connected
Figure 1 – 25-pin female D-sub connector
25-pin D-sub connector pinout
* Pins 1 and 25 are connected together internally.
851000292 (Rev. B)
Power Supply
R
V
Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host.
The power must be between 10 and 30 Vdc only.
SCANNER
VS
GND
CHASSIS
13/9
25
1
USER INTERFACE
V+ (10 - 30 Vdc)
GND
Inputs
The yellow LED is on when the External Trigger forces a current flow through the EXT TRIG+ and EXT TRIG- pins.
This input is optocoupled and can be driven by both an NPN or PNP type command. The connections are indicated in the following diagrams:
SCANNER
+ 5V
Figure 2 - Input NPN command using external power
+ 5V
Figure 3 - Input NPN command using scanner power
18
19
Vext
EXT TRIG+
EXT TRIG-
VS
9
EXT TRIG+
18
EXT TRIG-
19
25
GND
30 Vdc max.
EXTERNAL TRIGGERSCANNER
EXTERNAL TRIGGER
V
Signal
V
Ground
Signal
ext
EXT TRIG+
EXT TRIG-
30 Vdc max.
EXTERNAL TRIGGE
V
Signal
Ground
SCANNER
+ 5V
18
19
Figure 4 - Input PNP command using external power
EXTERNAL TRIGGERSCANNER
+ 5V
18
19
25
VS9
EXT TRIG+
EXT TRIG-
GND
V
Signal
Ground
Figure 5 - Input PNP command using scanner power
For DS1100, the general purpose input IN1 is used in the Standard Application Program to store the code verifier (see “Store Verifier HW” in the WinHost Help On Line). Use the input connections indicated in the figure below. For DS2200, this input is not used.
SCANNER
47 K
13/9
VS
17
IN1 -
I/O REF
22
Figure 6 - IN1 - Input command