Datalogic PowerScan BT8300 Family Quick Reference Manual

PowerScan™ BT8300 Family
Industrial Handheld
Bar Code Reader with
Bluetooth® Wireless Technology
Quick Reference Guide
Datalogic Scanning, Inc.
Eugene, Oregon 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the
procedures described therein may be reproduced or transmitted in any form or by any means with-
out prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic"
or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revo-
cable license to reproduce and transmit this documentation for the purchaser's own internal busi-
ness purposes. Purchaser shall not remove or alter any proprietary notices, including copyright
notices, contained in this documentation and shall ensure that all notices appear on any reproduc-
tions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contact-
ing your Datalogic representative. Electronic versions may either be downloadable from the Data-
logic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our
website and would like to make comments or suggestions about this or other Datalogic publica-
tions, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete
and accurate, however, Datalogic reserves the right to change any specification at any time with-
out prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A and the E.U. All other brand and product names referred to herein may be
trademarks of their respective owners.
Patents
This product is covered by one or more of the following patents:
Design Pat. AU 310201; AU 310202; CN 693980; CN735959; HK 0602013.5M001; HK
0602013.5M002; JP 1305693; KR 30-0460940; US D570,843 S; USD588,596 S.
US Pat. 5,992,740; 6,305,606 B1; 6,412,698 B2; 6,517,003; 6,808,114 B1; 6,997,385 B2; 7,387,246 B2; 5,367,151; 5,449,893; 5,545,889; 6,098,877; 6,220,514 B1; 6,412,698 B2; 6,607,132 B1; 6,817,529 B2; 6,834,805 B2.
European Pat. 789,315 B1; 895,175 B1; 1,128,314 B1; 1,128,315 B1; 1,396,811 B1; 1,413,971 B1; 1,816,585 B1; 1,942,442 B1.
Additional patents pending.
Quick Reference Guide 1
Table of Contents
Using the PowerScan™ BT8300....................................................................... 3
Scan Line Position .........................................................................................3
Reading Angle ................................................................................................3
Aiming System ...............................................................................................4
Installing the Battery Pack................................................................................. 5
Charging the Batteries ................................................................................. 7
Setup......................................................................................................................... 8
Restore PowerScan BT 8300 Default ......................................................8
Date and Time Setup ................................................................................... 8
Connecting the PowerScan BT8300.............................................................. 9
Overview ........................................................................................................... 9
PowerScan™ BT8300/BC 8030-BT Configuration ........................9
PowerScan™ BT8300/Bluetooth-Enabled PC Configuration .. 9
Before You Begin .........................................................................................10
Unpairing the Reader .........................................................................10
Linking the PowerScan™ BT8300 to the BC 8030-BT Cradle ........10
Link by Contact .....................................................................................11
Link by Inquiry .......................................................................................12
Link by Label ..........................................................................................12
Linking the PowerScan BT8300 to a Bluetooth-Enabled PC ........13
Linking to a PC in Serial Port Profile (Slave) Mode ...................13
Linking to a PC in Serial Port Profile (Master) Mode ................14
Linking to a PC in HID .........................................................................15
Variable PIN Code ................................................................................15
PowerScan BT8300 HID Configuration ................................................16
HID Country Codes ..............................................................................16
Caps Lock State ............................................................................................19
Caps Lock Auto-Recognition (IBM AT Compatible Only) ..............19
Alt Mode .........................................................................................................19
PowerScan™ BT8300 Default Configuration ........................................... 20
Technical Features............................................................................................ 21
Reading Distance .............................................................................................. 22
Warranty ............................................................................................................... 23
Service and Support ......................................................................................... 23
Compliance ......................................................................................................... 24
FCC Compliance ...........................................................................................24
Radio Compliance .......................................................................................24
2 PowerScan® BT8300
Laser Safety Compliance .......................................................................... 24
LED CLASS ..................................................................................................... 25
IC (Industry Canada) ................................................................................... 25
WEEE Compliance ....................................................................................... 26
Hex/Numeric Table ........................................................................................... 27
Quick Reference Guide 3
PowerScan™ BT8300 Reader
Using the PowerScan™ BT8300
The PowerScan™ BT8300 family of readers can be used with either the PowerScan BC 8030-BT base station or a Bluetooth-enabled PC to build a Cordless Reading System for the collection, decoding and transmission of bar coded data.
PowerScan
BT8300 laser readers automatically scan bar codes at a distance.
Simply aim and pull the trigger.
Scan Line Position
Code scanning is performed along the scan line emitted from the reading window. This line must cross the entire code. The best reading angles are indicated in the figure below:
Reading Angle
Successful scanning is obtained by tilting the reader with respect to the bar code to avoid direct reflections that impair the reading performance, see the figure below.
Using the PowerScan™ BT8300
4 PowerScan™ BT8300
Aiming System
PowerScan™ BT8300 provides an aiming system. If enabled, a partial trigger press produces a red spot, which should be aimed over the code center to get the best reading performance, see (1) in the figure above. By completely pressing the trigger the scan line appears to start the code scanning, see (2).
After setting up the reader
, you can enable or disable the aiming system by reading
the codes below:
Disable Aiming System (Default)
Ì$+Bj0$-"Î
Enable Aiming System
Ì$+Bj1$-'Î
Installing the Battery Pack
Quick Reference Guide 5
Installing the Battery Pack
To install, charge and/or do any other action on the battery, follow the instructions in this manual.
To charge the Battery Pack, See “Charging the Batteries” on page 7.
Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance.
WARNING
Do not discharge the battery using any device except for the scanner. When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury. Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions. Be sure to follow the safety warnings listed below:
• Do not place the battery pack in fire or heat.
• Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object (such as wire).
• Do not carry or store the battery pack together with metal objects.
• Do not pierce the battery pack with nails, strike it with a ham­mer, step on it or otherwise subject it to strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or allow the battery to get wet.
• Do not apply voltages to the battery pack contacts.
In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
Installing the Battery Pack
6 PowerScan™ BT8300
As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In other words, the batteries should be expected to take 500 full discharge / charge cycles before needing replacement. This number is higher if partial discharging / recharging is adhered to rather than full / deep discharging,
The typical manufacturer advertised useful life of LI batteries is one to three years, depending on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it should be properly recycled / disposed of and replaced. For most applications, batteries should be replaced after one year of service to maintain customer satisfaction and minimize safety concerns.
Collect and recycle waste batteries separately from the device in comply with European Directive 2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent modifications, US and China regulatory and others laws and regulations about the environment.
CAUTION
Always charge the battery at 32° – 113°F (0° - 45°C) tempera­ture range.
Use only the authorized power supplies, battery pack, char­gers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your warranty.
Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
Do not place the battery in or near fire, on stoves or other high temperature locations.
Do not place the battery in direct sunlight, or use or store the battery inside cars in hot weather. Doing so may cause the bat­tery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high-pressure containers or on induction cookware.
Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way.
Do not replace the battery pack when the device is turned on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
Installing the Battery Pack
Quick Reference Guide 7
Charging the Batteries
Once the BC 8030-BT/C-8000 is powered, you can charge the reader's batteries. Place the PowerScan
BT8300 into the BC 8030-BT cradle or the C-8000
battery charger. The Reader LED on the cradle/battery charger turns red.
The battery is completely charged when the Reader LED on the cradle/battery charger turns green.
Figure 1.
Changing the Batteries
Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force.
WARNING
1
2
Setup
8 PowerScan™ BT8300
Setup
Restore PowerScan BT 8300 Default
Before starting configuration and every time you want to restore factory settings, read the label below. Please note that the default mode on PowerScan BT8300 is Handheld - Cradle communication:
Restore PowerScan BT 8300 Default
Date and Time Setup
Scan the following bar codes in sequence to set the date and time for the PowerScan BT8300.
1.
Enter Configuration
2.
Set Date
3.
+
Six digits for Day, Month and Year (DDMMYY)
4.
Set Time
5.
+
Four digits for Hours and Minutes (HHMM)
6.
Exit and Save Configuration
Loading...