Datalogic DS4600A Quick Reference Manual

DS4600A
Laser Barcode Reader
Quick Reference Guide
The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations.
For installation, use and maintenance it is not necessary to open the device.
There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed.
The laser beam can be switched off through a software command (see also the WinHost Help On-Line).
Figure A
Cable with 25-pin Connector Laser Beam Output Window
Warning Label Mounting Holes
A
ccessory Mounting Holes
Data TX LED
Good Read LED Ready LED
External Trigger LED
Warning and Classification Labels
1 2
3 4 5
6
7
10
8 9
Keypad
11
Display
12
DATALOGIC S.p.A . Via Candini, 2 40012 LIPPO DI CALDERARA (BO) ITALY
Model No. Serial No . Volt Amp. Manufactured This product conform s to the applicable requirements of
21CFR1040 at the date of manufacture.
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVE LENGTH 630~680 nm
TO IEC 825-1 (1 993)
Warning and device class labels
For further details on product installation, see the complete Installation Manual available on the WinHost CD included with this product.
POWER SUPPLY
- This product is intended to be installed by Qualified Personnel only.
The laser diode used in this device is classified as a class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulations. As it is not possible to apply a classification label on the laser diode used in this device, the following label is reproduced below.
- Models DS4600A-XXX0:
This device is intended to be supplied by a UL Listed Direct Plug-in Power Unit marked “Class 2”, rated 10-30 V minimum, 0.60 A. This device may also be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25-pin connector.
- Model DS4600A-2XX5:
This device is intended to be supplied by a UL Listed Direct Plug-in Power Unit marked “Class 2”, rated 24 V minimum, 0.50 A. This device may also be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25-pin connector.
LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT
MAX. OUTPUT RADIATION 30 mW
EMITTED WAVE LENGTH 630~680 nm
TO IEC 825-1 (1993)
Laser diode class label
Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (30 mW at 630 to 680 nm).
DS4600A - 2XXX Models
6
7
8 9
10
5
1
4
2
3
11
12
2
DS4600A - 3XXX Models
DS4600A QUICK GUIDE
Available Models:
DS4600A - X X X X
Decoding Mode
2
= Standard w/ Display
3 = Advanced Code Reconstruction
Reading Range
0 = Medium Range 1 = Long Range 2 = Short Range
Optic
V
ersion
0 = Linear 1 = Raster R1 2 = Raster R2
Special Features
0 = Standard 5 = Integrated Heater
The following table displays each version’s reading performance.
Version Reading Distance
Max Code Resolution
mm (mils)
Speed
scans/s
210X 200 mm (8 in) - 980 mm (39 in) on 1.00 mm (40 mils) codes 0.50 (20) 800 200X 160 mm (6 in) - 540 mm (21 in) on 0.50 mm (20 mils) codes 0.25 (10) 800 220X 50 mm (1.9 7 in) - 400 mm (15.75 in) on 0.80 mm (31 mils) codes 0.20 (8) 800 310X 200 mm (8 in) - 970 mm (38 in) on 1.00 mm (40 mils) codes 0.50 (20) 800 300X 160 mm (6 in) - 540 mm (21 in) on 0.50 mm (20 mils) codes 0.25 (10) 800 320X 120 mm (4.7 in) - 310 mm (12.2 in) on 0.30 mm (12 mils) codes 0.20 (8) 800
ELECTRICAL FEATURES SOFTWARE FEATURES Power Supply
Model XXX0: 10 –30 Vdc Model 2XX5: 24 Vdc
Readable Codes
EAN/UPC (including Add-on 2 and Add-on 5)
Power Consumption max.
Model XXX0: 6W Model 2XX5: 12W
Code 39 2/5 Interleaved
Main Serial Interface
RS232; RS485 Full-Duplex/ Half-Duplex; 20 mA C.L. (only with INT-24 accessory)
Code 128 EAN 128 Code 93 Codabar
Auxiliary Interface
RS232
Pharmacode
Baudrates
1200 to 115200
Inputs
Headers and
Up to four header and four
External Trigger, IN1, IN2
(optocoupled NPN or PNP)
Terminators
terminator characters
Voltage max.
30 Vdc
Operating Modes
On-Line, Automatic,
Current Consumption
25 mA
Serial-On-Line, Test
max.
Configuration Modes
Through menus using
Outputs
WinHost utility Host Mode (commands from
OUT1, OUT2
(optocoupled OE or OC)
one of the serial ports)
V
CE
max.
40 Vdc
Code Selection
Up to six different codes
Collector Current
40 mA continuous;
during one reading phase
max.
130 mA pulsed
Parameter Storage
Non-volatile internal
VCE Saturation
1V at 10 mA max.
EEPROM
Power Dissipation
90 mW at 40 °C
ENVIRONMENTAL FEATURES
max.
(Ambient temp.)
Operating
0° to 40 °C (32° to 104 °F)
OPTICAL FEATURES Temperature
2XX5: -30° (-22 °F) to 40 °C
Light Source
Semiconductor laser diode
Storage
-20° to 70 °C (-4° to 158 °F)
Wavelength
630 to 680 nm
Temperature
Safety Class
Class 2 - EN 60825-1; CDRH
Humidity max
90% non condensing
Protection Class
IP65
USER INTERFACE
PHYSICAL FEATURES LED Indicators
Ready, Good Read,
Dimensions
101x84x42 mm
(4x3.3x1.7 in)
External Trigger,
Weight
615 g.
(22 oz)
Data TX
DS4600A QUICK GUIDE
Accessories:
Name Description Part Number
C-BOX 100/200 Connection Box 93ACC1510, 93ACC1520 C-BOX 300/310 Connection Box Profibus 93A301000, 93A301030 GFC-41 90° Reading Device 91D081000 OM4000 Oscillating Mirror 93A251030 INT-24 20 mA Current Loop Interface Board 93A151000
Electrical Connections:
DS4600A is equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power supply and input/output signals.
CAUTION
Do not connect GND and SGNDs to different (external) ground references. GND and SGNDs are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
The details of the connector pins are indicated in the following table:
25-pin D-sub female connector pinout
Pin Name Function
13 VS Power supply input voltage + 25 GND Power supply input voltage -
1 CHASSIS Chassis Ground
9 VS External Trigger supply voltage + 18 EXT TRIG+ External Trigger + 19 EXT TRIG- External Trigger -
6 IN1+ Input 1 + 10 IN1- Input 1 ­14 IN2+ Input 2 + 15 IN2- Input 2 -
8 OUT1 + Output 1 + 22 OUT1- Output 1 ­11 OUT2 + Output 2 + 12 OUT2- Output 2 ­20 RXAUX Auxiliary RS232 21 TXAUX Auxiliary RS232 23 SGND Aux Signal Ground Auxiliary interface 24 GND Power Supply Voltage ­16 Reserved 17 Reserved
25-pin female connector
Pin RS232
RS485
Full-Duplex
RS485
Half-Duplex
20 mA C.L.
(INT-24 Only)
2 TX232 TX485+ RTX485+
3 RX232 RX485+
4 RTS232 TX485- RTX485- CLOUT-
5 CTS232 RX485- CLIN-
7 SGND Main SGND Main SGND Main SGND Main
DS4600A QUICK GUIDE
Mechanical Installation:
10
0.39
41.8
1.64
M4 N° 4
37
1.47
5
0.2
11.8
0.46
81
3.19
8.25
0.32
87.9
3.46
M4 N°2
58
2.28
32.5
1.28
3.75
0.15
42
1.65
20
0.79
83.5
3.29
101
3.98
18
0.70
0.90
23
DS4600A
37
20.2
1.46
22*
0.86
0.8
14.8
0.58
39.4
1.55
* The quote refers to the scan lineMounting hole depth M4 X 5
Figure - Overall dimensions for 2XXX Models
M4 N°2
58
2.28
32.5
1.28
3.75
0.15
42
1.65
37
20.2
1.46
18*
0.71
0.8
14.8
0.58
39.4
1.55
0.90
0.70
18
23
101
3.98
20
0.79
3.29
83.5
* The quote refers to the scan line
Figure - Overall dimensions for 3XXX Models
Input/Output Connections:
Open Collector
USER INTERFACE
+
8/11
12/22
-
DS4600A 25-pin
Vext 40 Vdc max.
C
E
Output open collector connections
V
CE
max = 40 Vdc
I max = 40 mA continuous
NPN NPN
+ 5V
DS4600A 25-pin
USER INTERFACE
Signal
V
Vext 30 Vdc max.
+
18/6/14
19/10/15 -
Input NPN command using external power
USER INTERFACE
DS4600A 25-pin
Signal
+ 5V
Ground
V
VS
9
25
GND
+
18/6/14
19/10/15 -
Input NPN command using DS4600A power
PNP
PNP
+ 5V
DS4600A 25-pin
USER INTERFACE
V
Signal
Ground
Vext 30 Vdc max.
+
18/6/14
19/10/1
5
-
Input PNP command using external power
USER INTERFACE
DS4600A 25-pin
+ 5V
Ground
V
Signal
VS
9
25
GND
+
18/6/14
19/10/15
-
Input PNP command using DS4600A power
5.5
0.22
115
4.53
57.3
2.26
5
.
5
0
.
2
2
1
0
°
5
39
1.54
5.5
0.22
3
0.12
5
.
5
0
.
2
2
35°
0.20
Mounting Bracket Dimensions