1.1 Description

These instructions give information on the torque values for the terminal blocks used in the VLT® Midi Drive FC 280.

1.2 Part Numbers

Table 1: Accessory Bag Numbers (Cannot be Ordered as Spare Parts)

Drive

Description

Part number

 

 

 

VLT® Midi Drive FC 280

Terminals for enclosure sizes K1–K3.

132B0420

 

Plug item: 1, 2, 3, 4, 5, 6, 7.

 

 

 

 

 

Terminals for enclosure sizes K4–K5.

132B0421

 

Plug item: 1, 2, 3, 4.

 

 

 

 

VLT® Midi Drive FC 280 with Ethernet Safety Functions

Accessory bag, plugs K1–K3.

132B0798

 

Plug item: 1, 4, 5, 6, 7, 10, 11.

 

 

 

 

 

Accessory bag, plugs K4–K5.

132B0799

 

Plug item: 1, 4, 10, 11.

 

 

 

 

Table 2: Spare Part Numbers

Description

Ordering number

 

 

Terminals for enclosure sizes K1–K5.

132B0350

Plug item: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11.

 

 

 

1.3 Safety Precautions

Only Danfoss qualified personnel is allowed to install this equipment.

For important information about safety precautions for installation, refer to the drive's Operating Guide.

1.4 Tools Required

SZS 0.6x3.5 mm slot screwdriver.

1.5 Torque Instructions

N O T I C E

DESTRUCTION OF TERMINALS OR LOOSE CABLES

Applying too much torque can destroy the terminal blocks. Applying too low torque can result in loose cables.

-

-

-

Only use a screwdriver as specified in 1.4 Tools Required. Apply the needed tightening torque as specified in Table 3.

Do not apply more torque than the maximum torque as specified in Table 3.

Danfoss A/S © 2021.12

AN375526175644en-000101 / 132R0174 | 1

Danfoss VLT Midi Drive FC 280 Installation guide

Terminal Torque Instructions

Installation Guide

1

2

Installation Instructions

3

<![if ! IE]>

<![endif]>e30bf224.12

 

4

5

6

7

8

9

10

11

Illustration 1: Tightening Torque for Terminals

Table 3: Tightening Torque for Terminals

Item

Designation

Tightening torque [Nm (in-lb)]

Maximum torque [Nm (in-lb)]

 

 

 

 

1

Plug connector, relay 1

0.5 (4.4)

0.6 (5.3)

 

 

 

 

2

I/O terminal plug, 10-pole

0.35 (3.1)

0.4 (3.5)

 

 

 

 

3

I/O terminal plug, 5-pole

 

 

 

 

 

 

4

I/O terminal plug, 3-pole

 

 

 

 

 

 

5

Motor plug, 3-pole 7.62

≤4 mm2/AWG 12: 0.5 (4.4),

≤4 mm2/AWG 12: 0.6 (5.3),

 

 

>4 mm2/AWG 12: 0.7 (6.2)

>4 mm2/AWG 12: 0.8 (7.1)

6

BR DC plug, 3-pole 7.62

 

 

 

 

 

 

7

Mains plug, 3-pole 7.62

 

 

 

 

 

 

8

CANopen plug, 5-pole

0.5 (4.4)

0.6 (5.3)

 

 

 

 

9

PROFIBUS plug, 5-pole

 

 

 

 

 

 

10

IO plug, 5-pole, 5 mm

0.35 (3.1)

0.4 (3.5)

 

 

 

 

11

IO plug, 8-pole, 5 mm

 

 

 

 

 

 

Danfoss A/S

Ulsnaes 1 DK-6300 Graasten

vlt-drives.danfoss.com

Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.