Danfoss VLT Memory Module Installation guide

Installation Instructions
VLT® Memory Module MCM 102 VLT® Midi Drive FC 280
The instructions provide information about installing the VLT
Memory Module MCM 102 in VLT® Midi Drive FC 280.
®
The VLT frequency converters. A memory module is a component that stores motor data, rmware, and parameter settings of a frequency converter. If a frequency converter malfunctions, the motor data, rmware, and parameter settings on this frequency converter can be copied to new frequency converters of the same power size. Copying the settings saves the time for setting up new frequency converters for the same applications.
The data and parameter settings on a memory module are encoded les that are protected from direct viewing.
To access les in a memory module, or transfer les to a memory module, a memory module programmer is required. It is not included in this package and must be ordered separately (ordering number: 134B0792).
Memory Module MCM 102 is an option for FC 280
®
The memory module can be inserted and removed during operation of the frequency converter, but it is only active after a power cycle. The personnel mounting or dismounting the memory module must be familiar with the safety instructions
®
and measures described in the VLT Operating Instructions.
Midi Drive FC 280
Items Supplied
Description Ordering number
®
Memory Module MCM 102
VLT
Tab le 1 . 1 O r deri n g Nu mbers
132B0359
Installation
1. Remove the plastic front cover of the frequency converter with a screwdriver.
1 Memory module
2 Status indicator light
3 Socket for memory module
4 Memory module programmer
5 USB Type-B receptacle
Illustration 1.1 Memory Module and Memory Module Programmer
Danfoss A/S © 02/2016 All rights reserved. MI07H102
Illustration 1.2 Removing the Front Cover of the Frequency
Converter
Installation Instructions
VLT® Memory Module MCM 102 VLT® Midi Drive FC 280
2. Open the lid of the memory module container.
Illustration 1.3 Lid Opened
4. Close the lid of the memory module container.
Illustration 1.5 Lid Closed
5. Mount the plastic front cover of the frequency converter.
3. Plug in the memory module on the frequency converter.
Illustration 1.4 Plugging in the Memory Module on the Frequency
Converter
Illustration 1.6 Mounting the Front Cover of the Frequency
Converter
6. When the frequency converter powers up, the data on the frequency converter is stored into the memory module.