VLT® 12-pulse drive

Robust and cost effective harmonic solution for the higher power range. The Danfoss VLT® 12-pulse drive offers reduced harmonics for demanding industry applications above 250 kW.

The VLT® 12-pulse is a high efficiency variable frequency converter which is built with the same modular design as the popular 6-pulse VLT® drives. It is offered with similar drive options and accessories and can be configured according to customer need.

Together with the needed 30°-phase shifting transformer the solution provides durability and reliability at a low cost.

Under ideal grid conditions the solution eliminates the 5th, 7th, 17th and 19th harmonics and results in a THiD of around 12% at full load.

The needed transformer makes this solution ideal for applications where stepping down from medium voltage is required or where isolation from the grid is needed.

The Danfoss VLT® 12-pulse drive provides harmonic reduction without adding capacitive or inductive components which often require network analysis to avoid potential system resonance problems.

Power Range:

n 250 kW – 1.4 MW

Voltage Range:

n 380 – 690 V

Enclosure:

nIP 21/NEMA Type 1

nIP 54/NEMA Type 12

Optimised

for:

VLT® HVAC Drive FC 102

VLT® AQUA Drive FC 202

VLT® AutomationDrive FC 302

Feature

Benefit

Reliable

Maximum uptime

Maintenance free

No running expenses

Durability

Long lifetime

Coated PCBs

Environmental robustness

100% factory tested

Low failure rate

Backchannel cooling

Prolonged lifetime of electronics

Design

Easy operation and user-friendly set-up

Modular design

Easy serviceability

Same easy programming as a 6-pulse drive

User-friendly operation

– Standard award-winning control panel (LCP)

Effective commissioning and operation

– Available in 27 languages

 

Facts about our products

Danfoss VLT 12-pulse drive Fact sheet

Options

The following options are available:

nRFI filters

nDisconnect

nFuses

nMains shielding

nFeedback and I/O options

nFieldbus options

ndU/dt filters

nSine wave filters

PC Software

VLT® MCT 10 Setup Software

VLT® MCT 10 offers advanced programming functionality for all Danfoss drive products, greatly reducing programming and set-up time.

VLT® MCT 10 Basic (available free of charge on www.danfoss.com) allows access to a finite number of drives with limited functionality. The advanced edition, offering a higher level of functionality, is available from your Danfoss sales partner.

VLT® MCT 31 Harmonics Calculation Software

With VLT® MCT 31 you can determine whether harmonics will be an issue in your installation when drives are added.

VLT® MCT 31 estimates the benefits of adding various harmonic mitigation solutions from the Danfoss product portfolio and calculates system harmonic distortion.

From www.danfoss.com you can download the free tool VLT® Harmonic Calculation MCT 31.

Specifications

THiD* at:

 

– 40% load

20%

– 70% load

14%

– 100% load

12%

Efficiency* at:

 

– 40% load

95%

– 70% load

97%

– 100% load

98%

True power factor* at:

 

– 40% load

91%

– 70% load

95%

– 100% load

97%

Ambient temperature

45° C without derating

Cooling

Back-channel air cooling

* Measured at balanced grid without pre-distortion

 

Norms and recommendations

Compliance

IEEE519

Depends on grid and load conditions

IEC61000-3-2 (up to 16 A)

Out of scope

IEC61000-3-12 (between 16 and 75 A)

Out of scope

IEC61000-3-4 (above 75 A)

Always

F10

F12

 

F8

 

400 V AC

 

 

460 V AC

 

 

690 V AC

 

Normal

High

Normal

High

Normal

High

Overload

Overload

Overload

Overload

Overload

Overload

Power

Current

Power

Current

Power

Current

Power

Current

Power

Current

Power

Current

[kW]

[A]

[kW]

[A]

[HP]

[A]

[HP]

[A]

[kW]

[A]

[kW]

[A]

Frame dimensions

Without options

With options

cabinet

cabinet

H x W x D

H x W x D

IP 21 [mm]

IP 21 [mm]

315

 

600

250

 

480

450

540

350

443

 

450

450

355

380

 

 

 

 

 

 

355

 

658

315

 

600

500

590

450

540

 

500

500

400

410

 

 

F8

 

F9

400

 

745

355

 

658

600

678

500

590

 

560

570

500

500

 

 

2280 x 800 x 607

2280 x 1400 x 607

450

 

800

400

 

695

600

730

550

678

 

630

630

560

570

 

 

 

 

 

 

500

 

880

450

 

800

650

780

600

730

 

710

730

630

630

 

 

 

 

 

 

560

 

990

500

 

880

750

890

650

780

 

800

850

710

730

 

 

F10

 

F11

630

 

1120

560

 

990

900

1050

750

890

 

900

945

800

850

 

 

2280 x 1600 x 607

2280 x 2400 x 607

710

 

1260

630

 

1120

1000

1160

900

1050

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

 

1460

710

 

1260

1200

1380

1000

1160

 

1000

1060

900

945

 

 

F12

 

F13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

 

1720

800

 

1460

1350

1530

1200

1380

 

1200

1260

1000

 

 

1160

2280 x 2000 x 607

2280 x 2800 x 607

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

1415

1200

1260

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DKDD.PFP.401.A2.02

VLT® is a trademark of Danfoss A/S

PE-MMSC 2014.09

Loading...