Danfoss VHX-DUO, VHX-MONO Data sheet

Data Sheet
VHX Valve Sets with RTX Temperature Limiter for Designer Radiators & Bathroom Towel Rails
Application
VHX floor connection VHX wall connection
Ordering
The VHX-sets are specially designed for towel rails and designer radiators with '50 mm bottom connection' and ½” connection to the radiator. The VHX-sets include a RTX temperature limiter for regulation of the return flow temperature.
VHX valves controls the return flow from the radi­ator and have several features:
free choice of left/right mounting direction
available in versions for floor or wall connec-
tion
VHX set
Description Colour
VHX-DUO valve set, with RTX return flow sensor
VHX-MONO valve set, with RTX return flow sensor
Compression fittings
Description Size
For steel and copper tubes
For AluPex tubes
For Pex tubes
built-in shut-off function
four different surfaces matching most radia-
tors
The VHX sets provides the perfect finishing touch for towel rails. The aesthetically pleasing and compact design allows the sensor to be mounted underneath the towel rail, parallel with the wall.
Chrome 013G4376 013G4379
RAL 9016 013G4378 013G4381
Chrome 013G4382 013G4385
RAL 9016 013G4384 013G4387
8 mm 013G4108 10 mm 013G4110 013G4192 12 mm 013G4112 013G4193 14 mm 013G4114 013G4194 15 mm 013G4115 013G4195 16 mm 013G4116 013G4196
12 x 2 mm 013G4172 14 x 2 mm 013G4174 16 x 2 mm 013G4176 013G4200
12 x 1.1 mm 013G4143 013G4197
12 x 2 mm 013G4142 14 x 2 mm 013G4144
15 x 2.5 mm 013G4147 013G4199
16 x 2 mm 013G4146 013G4198
Code no.
Straight
Code no.
Nickel plated
Code no.
Angle
Code no.
Chrome plated
Danfoss Heating Solutions VDUYN402 © Danfoss 10/2011 1
Xp = 0 K
Xp = 5 K
min. 20 30 40 50 max. °C
0 I 1 2 3 4 uI
min. 15 25 35 45 max. °C
Data Sheet
VHX Valve Sets with RTX Temperature Limiter for Designer Radiators & Bathroom Towel Rails
Accessories
Technical Data
Product Code no.
Electric heating element - 47 cm - 300 W - 1.2 m w/ Schuko plug Electric heating element - 40 cm - 150 W - 1.2 m w/ Schuko plug Electric heating element - 70 cm - 600 W - 1.2 m w/ Schuko plug Adapter for electric heating element 013G4166 O-ring service set for VHX MONO angle valve and VHX DUO angle valve O-ring service set for VHX DUO straight valve 013G4180 O-ring service set for VHX MONO straight valve 013G4181
1)
Electric heating elements are according to the standard UNEL 47168/68-CEE (7) xvll.
2)
Complete O-ring replacement of VHX DUO angle valve requires 2 x 013G4179.
Type
VHX-DUO G½A
VHX­MONO
Max. work. pressure: 10 bar, max. diff. pressure2): 0,6 bar, test pressure 16 bar, max. flow temp.: 120 °C
1)
The kv-value indicates the water flow (Q) in m³/h at a pressure drop (Δp) across the valve of 1 bar; . The kvs-
value states the flow Q at a maximum lift, i.e. at fully open valve at setting N.
2)
The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regula­tion. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. The differential pressure can be reduced by the use of the Danfoss differential pressure regulators.
Connection
Rad. Sys. 1 2 3 4 5 6 7 N N
G½A
P-band
2K 0.12 0.14 0.16 0.17 0.18 0.19 0.20 0.21 5K 0.16 0.19 0.22 0.25 0.29 0.33 0.37 0.41 2K 0.12 0.14 0.16 0.17 0.18 0.19 0.20 0.21 5K 0.16 0.19 0.22 0.25 0.29 0.33 0.37 0.41
kv-values [m³/h] with RAX sensor at setting
1)
1)
1)
2)
013G4167 013G4168 013G4169
013G4179
1)
(kvs)
0.56
0.45
Temperature Setting
Pre-Setting
RTX has - due to its mode of operation - a very limited influence on the hydraulic balance of the
Changing the kv-setting from "N" (factory setting) is therefore seldom required.
heating system.
At position 0 the valve is totally closed, i.e. the frost protection is off.
Danfoss pre-settable valve assemblies incorporate easy setting adjust­ment with clearly engraved setting markers scaled from 1 - 7 and N. Setting values can be set quickly and precisely, without the need for tools, as follows:
Remove protective cap or sensor.
Turn Red ring to the desired setting value.
The preset level can be selected in 0.5 increments between 1 and 7 (see chart for flow rates). At setting N the valve is fully open (flushing option).
2 VDUYN402 © Danfoss 10/2011 Danfoss Heating Solutions
Data Sheet
VHX Valve Sets with RTX Temperature Limiter for Designer Radiators & Bathroom Towel Rails
Installation
VHX-DUO floor connection
Free connection (left or right). Radiator outlet always on thermostat side.
VHX-DUO wall connection
Free connection (left or right). Radiator outlet always on thermostat side.
VHX-MONO floor connection
Free connection (left or right). Radiator outlet always on thermostat side.
VHX-MONO wall connection
Free connection (left or right). Radiator outlet always on thermostat side.
Electric Heating Element
RTX sensor
Replace gland seal on valve by the special RTX gland seal before mounting of the sensor with an Allen key (enclosed).
Danfoss electric heating elements can be moun­ted in the radiator through the VHX-DUO angle valve. Mounting of a standard heating element (non-Danfoss) through the valve requires use of the adapter 013G4166.
Examples: Mounting of an electric heating element
If a heating element is to be used with other VHX valves, a standard heating element (non-Danfoss) has to be mounted directly in the radiator.
Danfoss Standard (non-Danfoss) Standard (non-Danfoss)
Danfoss Heating Solutions VDUYN402 © Danfoss 10/2011 3
G½A
80
18,5
16
35,5
43
46
34,8
45
50
32
45
21
38
45,1
35
80
32,8
50
19
20
46
43
G½A
50
45
21
26
34,8
45
4521
32
80
16
25
44
35,5
43
46
G½A
Ø 11 x 205 mm
80
19
25 44
20
43
46
45,1
35
44
38
25
44
21 45
26
G½A
19
Ø 11 x 205 mm
Data Sheet
Dimensions
VHX Valve Sets with RTX Temperature Limiter for Designer Radiators & Bathroom Towel Rails
VHX-DUO floor connection VHX-DUO wall connection
VHX-MONO floor connection VHX-MONO wall connection
Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone: +45 7488 8000 Fax: +45 7488 8100 Email: heating.solutions@danfoss.com www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved.
4 VDUYN402 © Danfoss 10/2011 Danfoss Heating Solutions
Loading...