Application
VHX floor connection VHX wall connection
Ordering
The VHX-sets are specially designed for towel rails and designer radiators with '50 mm bottom connection' and ½” connection to the radiator.
The VHX-sets include a RAX thermostatic sensor for room temperature regulation.
The sets provides the perfect finishing touch for towel rails. The aesthetically pleasing and com­pact design allows the sensor to be mounted un­der-neath the towel rail, parallel with the wall.
VHX set
Description Colour
VHX-DUO valve set, with RAX room sensor
VHX-MONO valve set, with RAX room sensor
VHX valves controls the return flow from the radi­ator and have several features:
free choice of left/right mounting direction
available in versions for floor or wall connec-
tion built-in shut-off function
two different surfaces matching most radia-
tors
Chrome 013G4276 013G4279
RAL 9016 013G4278 013G4281
Chrome 013G4282 013G4285
RAL 9016 013G4284 013G4287
Code no.
Straight
Code no.
Angle
Danfoss Heating Solutions VDVJJ102 © Danfoss 04/2013 1
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Compression fittings
Description Size
Code no.
Nickel plated
8 mm 013G4108
10 mm 013G4110 013G4192
For steel and copper tubes
12 mm 013G4112 013G4193 14 mm 013G4114 013G4194 15 mm 013G4115 013G4195 16 mm 013G4116 013G4196
12 x 2 mm 013G4172
For AluPex tubes
14 x 2 mm 013G4174 16 x 2 mm 013G4176 013G4200
12 x 1.1 mm 013G4143 013G4197
12 x 2 mm 013G4142
For Pex tubes
14 x 2 mm 013G4144
15 x 2.5 mm 013G4147 013G4199
16 x 2 mm 013G4146 013G4198
Code no.
Chrome plat-
ed
Accessories
Technical Data
Product Code no. O-ring service set for VHX MONO angle valve and VHX DUO angle valve
1)
013G4179
O-ring service set for VHX DUO straight valve 013G4180 O-ring service set for VHX MONO straight valve 013G4181
1)
Complete O-ring replacement of VHX DUO angle valve requires 2 x 013G4179.
Type
Connection
kv-values [m³/h] with RAX sensor at setting
1)
Rad. Sys. 1 2 3 4 5 6 7 N N
(kvs)
VHX-DUO G½A 0.12 0.15 0.20 0.25 0.30 0.36 0.42 0.49 0.56 VHX-
MONO
G½A 0.12 0.15 0.20 0.25 0.30 0.34 0.38 0.40 0.45
Max. work. pressure: 10 bar, max. diff. pressure2): 0,6 bar, test pressure 16 bar, max. flow temp.: 120 °C
1)
The kv-value indicates the water flow (Q) in m³/h at a pressure drop (Δp) across the valve of 1 bar;
. At setting N the kv-value is stated according to EN 215, at XP = 2K i.e. the valve is closed at 2°C
higher room temperature. At lower settings the XP value is reduced to 0.5K of the setting value 1. The kvs-value states the flow Q at a maximum lift, i.e. at fully open valve at setting N.
2)
The maximum differential pressure specified is the maximum pressure at which the valves give satis­factory regulation. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. The differential pressure can be reduced by the use of the Dan­foss differential pressure regulators.
2 VDVJJ102 © Danfoss 04/2013 Danfoss Heating Solutions
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Capacities
VHX-DUO (RAX) (pre-setting)
VHX-MONO (RAX) (pre-setting)
Danfoss Heating Solutions VDVJJ102 © Danfoss 04/2013 3
8 12 16 20 24 28 °C
0 T I II III IIII uI
T
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Temperature Setting
Presetting
RAX thermostatic sensor
0= Positive shut off
= Frost protection setting
Danfoss pre-settable valve assemblies incorpo­rate easy setting adjustment with clearly en­graved setting markers scaled from 1 - 7 and N.
Setting values can be set quickly and precisely, without the need for tools, as follows:
Remove protective cap or sensor.
Turn red ring to the desired setting value.
The preset level can be selected in 0.5 increments between 1 and 7 (see chart for flow rates). At set­ting N the valve is fully open (flushing option).
4 VDVJJ102 © Danfoss 04/2013 Danfoss Heating Solutions
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Installation
VHX-DUO floor connection VHX-MONO floor connection
Free connection (left or right). Free connection (left or right). Radiator outlet always on thermostat side. Radiator outlet always on thermostat side.
VHX-DUO wall connection VHX-MONO wall connection
Free connection (left or right). Free connection (left or right). Radiator outlet always on thermostat side. Radiator outlet always on thermostat side.
RAX sensor
Mounted directly on the valve with an Allen key (enclosed in set)
Danfoss Heating Solutions VDVJJ102 © Danfoss 04/2013 5
G½A
80
18,5
16
35,5
43
46
34,8
45
50
32
45
21
38
45,1
35
80
32,8
50
19
20
46
43
G½A
50
45
21
26
34,8
45
4521
32
80
16
25
44
35,5
43
46
G½A
Ø 11 x 205 mm
80
19
25 44
20
43
46
45,1
35
44
38
25
44
21 45
26
G½A
19
Ø 11 x 205 mm
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Dimensions
VHX-DUO floor connection VHX-DUO wall connection
VHX-MONO floor connection VHX-MONO wall connection
6 VDVJJ102 © Danfoss 04/2013 Danfoss Heating Solutions
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Danfoss Heating Solutions VDVJJ102 © Danfoss 04/2013 7
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone: +45 7488 8000 Fax: +45 7488 8100 Email: heating.solutions@danfoss.com www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved.
8 VDVJJ102 © Danfoss 04/2013 Danfoss Heating Solutions
Loading...