Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor
for Designer Radiators & Bathroom Towel Rails
Application
VHX floor connection VHX wall connection
Ordering
The VHX-sets are specially designed for towel
rails and designer radiators with '50 mm bottom
connection' and ½” connection to the radiator.
The VHX-sets include a RAX thermostatic sensor
for room temperature regulation.
The sets provides the perfect finishing touch for
towel rails. The aesthetically pleasing and compact design allows the sensor to be mounted under-neath the towel rail, parallel with the wall.
VHX set
Description Colour
VHX-DUO valve set, with RAX room sensor
VHX-MONO valve set, with RAX room sensor
VHX valves controls the return flow from the radiator and have several features:
free choice of left/right mounting direction
▪
available in versions for floor or wall connec-
▪
tion
built-in shut-off function
▪
two different surfaces matching most radia-
▪
tors
Chrome 013G4276 013G4279
RAL 9016 013G4278 013G4281
Chrome 013G4282 013G4285
RAL 9016 013G4284 013G4287
Code no.
Straight
Code no.
Angle
Danfoss Heating Solutions VDVJJ102 © Danfoss 04/2013 1
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Compression fittings
Description Size
Code no.
Nickel plated
8 mm 013G4108 –
10 mm 013G4110 013G4192
For steel and copper tubes
12 mm 013G4112 013G4193
14 mm 013G4114 013G4194
15 mm 013G4115 013G4195
16 mm 013G4116 013G4196
12 x 2 mm 013G4172 –
For AluPex tubes
14 x 2 mm 013G4174 –
16 x 2 mm 013G4176 013G4200
12 x 1.1 mm 013G4143 013G4197
12 x 2 mm 013G4142 –
For Pex tubes
14 x 2 mm 013G4144 –
15 x 2.5 mm 013G4147 013G4199
16 x 2 mm 013G4146 013G4198
Code no.
Chrome plat-
ed
Accessories
Technical Data
Product Code no.
O-ring service set for VHX MONO angle valve and VHX DUO angle valve
1)
013G4179
O-ring service set for VHX DUO straight valve 013G4180
O-ring service set for VHX MONO straight valve 013G4181
1)
Complete O-ring replacement of VHX DUO angle valve requires 2 x 013G4179.
Type
Connection
kv-values [m³/h] with RAX sensor at setting
1)
Rad. Sys. 1 2 3 4 5 6 7 N N
(kvs)
VHX-DUO G½A G½ 0.12 0.15 0.20 0.25 0.30 0.36 0.42 0.49 0.56
VHX-
MONO
G½A G½ 0.12 0.15 0.20 0.25 0.30 0.34 0.38 0.40 0.45
Max. work. pressure: 10 bar, max. diff. pressure2): 0,6 bar, test pressure 16 bar, max. flow temp.: 120 °C
1)
The kv-value indicates the water flow (Q) in m³/h at a pressure drop (Δp) across the valve of 1 bar;
. At setting N the kv-value is stated according to EN 215, at XP = 2K i.e. the valve is closed at 2°C
higher room temperature. At lower settings the XP value is reduced to 0.5K of the setting value 1. The
kvs-value states the flow Q at a maximum lift, i.e. at fully open valve at setting N.
2)
The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. As with any device which imposes a pressure drop in the system, noise may occur
under certain flow/pressure conditions. The differential pressure can be reduced by the use of the Danfoss differential pressure regulators.
2 VDVJJ102 © Danfoss 04/2013 Danfoss Heating Solutions
Data Sheet
VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails
Capacities
VHX-DUO (RAX) (pre-setting)
VHX-MONO (RAX) (pre-setting)
Danfoss Heating Solutions VDVJJ102 © Danfoss 04/2013 3