Danfoss TP5001 User guide

Easy User Guide
SET
TP5001
Programmable Room Thermostat
BC337370422703en-000102 | 087R1003
www.danfoss.com
Display & Navigations
Symbols Function description Symbols Function description
Mon – Sun Current set day
1 2 3 4
AM PM
Current on/off period Holiday mode
Current set time / parameter number in setup
Room temperature
Temperature indication Power on/off
Set temperature
Heating active M
Frost protect active
Schedule mode
RF Status (TP5001RF only)
Battery low indicator (TP5001B & TP5001RF only)
Timer and program operation
Mode change / option setting
Temperature / option setting selectors
What is a programmable room thermostat?
A programmable thermostat allows you to set times at which you want you heating to be at a specific temperature. A room thermostat works by sensing the air temperature and switching on the heating when the air temperature falls below the thermostat setting, switching it off once this set temperature has been reached. The TP5001 programmable room thermostat has made intelligent heating control easier than ever before.
Setting Time and Date
a. Press button , the screen will change to show the current year. b. Adjust using or to set the correct year. Press to accept. Repeat step b to set
month and time settings.
Advanced Programmable Timer
The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature, and an energy-saving lower setback temperature if standard room comfort temperature is not required. Example below for 5/2 day setup, 4 Temperature settings The function consists of 2 programs:
P1 with 4 events over weekdays (Mon. To. Fri.) P2 with 4 events over weekends (Sat. Sun.).
P1: Press
The press for 3 seconds to display Mo. Tu. We. Th. Fr.
P1, Event 1:
1. Use or to select the start hour.
2. Press to accept the setting.
3. Use or to set the minute.
4. Press to accept the setting.
5. Use or to select the temperature.
6. Press to accept the setting.
P1, Event 2–4: Repeat the Event 1 procedure for programming Events 2–4.
If the working mode is set to 24hr, only P1 program will be available (same times each day of the week), to change this see the User settings section of this document.
once to activate product.
P2: Sa. Su. are now shown in the display.
P2, Event 1:
1. Use or to select the start hour
2. Press to accept the setting.
3. Use or to set the minute.
4. Press to accept the setting.
5. Use or to select the temperature.
6. Press to accept the setting.
P2, Event 2–4:
Repeat the Event 1 procedure for programming Event 2–4.
Display and Navigation Details
Setting/Changing the Temperature
a. Press or at any time to change the desired temperature value. SET is shown
in the display.
b. When releasing the or , after around 5 seconds, the display returns to
showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting.
Holiday Mode
Holiday Mode selects the comfort temperature typically when the home is unoccupied
a. Press M to enter into Holiday mode and will be displayed.
b. Holiday mode temperature can be set in User settings, 07. c. Press M again to exit Holiday mode.
Frost Protection Temperature
a. The thermostat is turned OFF (Standby) mode by pressing . In OFF (Standby)
mode the thermostat is set to Frost Protect temperature setting and will switch the output On if the measured temperature falls below the frost protection temperature setting.
b. Frost protect icon and current temperature will be display.
User Settings
a. Press M button once to illuminate screen, next press M for 6 seconds to enter the
User setting mode. Press M for parameter selection and set the parameter range via
or . Complete all adjustments.
b. To exit press , automatic exit after 20 seconds when no button is pressed.
No. Parameter settings Settings range Default
01 Working mode
02 Heat control mode
Heat control start-up
03
mode
04 Temperature limit high Between low (05) and 35° C 35° C
05 Temperature limit low Between 5° C and high (04) 5° C
06 Frost protect temperature Between 5° C and 15° C 5° C
07 Holiday mode temperature Between low (05) and high (04) 18° C
08 Timer display
09 Service due setup Installer setting only
10 RF Pairing (TP5001RF only)
11 Auto daylight saving
01: Manual 02: Schedule timer 5/2 day 03: Schedule timer 24hr
01: On/off load compensation 02: On/off standard
01: Normal start control 02: Delayed start control 03: Optimised start control
01: 24hr 02: 12hr
00: RF pairing mode off 01: RF pairing mode on
01: On 02: Off
02
01
01
24hr
00
01
Danfoss A/S
Heating Segment • danfoss.com • +45 7488 2222 • E-mail: heating@danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed ma­terial. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logo­type are trademarks of Danfoss A/S. All rights reserved.
© Danfoss | FEC | 09.2020
087R1003
Loading...