TLS5FT
Tropical Compressor
R134a
220-240V 50Hz
General
Code number 102G4524
Approvals EN 60335-2-34
Compressors on pallet 125
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10 –
Voltage range V 187 - 254 –
Max. condensing temperature continuous (short) °C 60 (70) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C S – – – – –
38°C S – – – – –
43°C S – – – – –
Remarks on application: In capillary tube systems where non-equalized pressures may
occur at compressor start, or in areas with short power supply drop-outs, a starting
capacitor can be used for ensuring a successful start (CSIR).
Motor
Motor type RSIR
LRA (rated after 4 sec. UL984), HST | LST A 5.7 5.4
Cut in Current, HST | LST A 5.7 9.7
Resistance, main | start winding (25°C) Ω 14.5 14.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 7.5
Dimensions
Height mm A 173
Suction connector location/I.D. mm | angle C 6.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 169
B1 –
B2 –
5.08
180 (polyolester)
1790
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.Y4.02 / 520N1372 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling, PTC consumption incl.
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 47.8 70.7 98.0 109 131 170 216
Power cons. in W 84.5 99.2 114 120 131 147 165
Current cons. in A 0.96 0.98 1.01 1.02 1.05 1.10 1.15
COP in W/W 0.57 0.71 0.86 0.91 1.00 1.15 1.30
ASHRAE LBP 220V, 50Hz, static cooling, PTC consumption incl.
Evap. temp in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 58.9 87.2 121 134 161 209 267
Power cons. in W 84.5 99.2 114 120 131 147 165
Current cons. in A 0.96 0.98 1.01 1.02 1.05 1.10 1.15
COP in W/W 0.70 0.88 1.06 1.12 1.24 1.42 1.61
Accessories for TLS5FT Figure Code number Test conditions EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 55°C
Starting relay 6.3 mm spade connectors a2 117U6000 Suction gas temperature 32°C 32°C
Start capacitor 60 µF 6.3 mm spade connectors c 117U5014 Liquid temperature no subcooling 32°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø : 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.Y4.02 / 520N1372 June 2012