General safety.................................................................................................................................................................................... 4
Dimensions and identification.....................................................................................................................................................6
Setting up the CB70 battery charger...................................................................................................................................... 10
CB70 status LEDs............................................................................................................................................................................11
Danfoss | December 2018BC292358159566en-000101 | 3
User Manual
T70 1 ATEX Transmitter
Safety instructions
T70 1 ATEX general safety
The following safety instructions must be read carefully in order to install and use the product properly
and to keep it in perfect working condition and to reduce the risk of misuse.
Potential damage to operator and product.
Do not use this product on machines in potentially explosive atmospheres unless the model is ATEX/
RATEX certified to do so.
•
Strictly adhere to the installation instructions contained in this document.
•
Make sure that professional and competent personnel carry out the installation.
•
Ensure that all site and prevailing safety regulations are fully respected.
•
Make sure that this document is permanently available to the operator and maintenance personnel.
•
Keep the transmission key when the set is not in use.
•
On starting each working day, check to make sure that the STOP button and other safety measures
are working.
•
When in doubt, press the STOP button.
•
Whenever several sets have been installed, make sure the transmitter is the right one. Identify the
machine controlled on the label for this purpose on the transmitter or by using the display (in case it
has one).
•
Service the equipment periodically.
•
When carrying out repairs, only use spare parts from Danfoss.
T70 1 ATEX safety warnings
Potential damage to operator and product.
Follow the guidelines below to reduce risk of injury to the operator and the product.
•
Use the device with the manufacturer's battery and battery charger (if applicable).
•
Only allow qualified personnel to operate the equipment.
•
Always set the STOP button in the off position when not in use.
•
Always press STOP before plugging in tether cable (if applicable).
•
Do not operate product when visibility is limited.
•
Make sure product is compatible with the machine.
•
Avoid knocking or dropping the product.
•
Do not use the product if a failure is detected.
Changes or modifications not approved by Danfoss can void the user's authority to operate this product.
Use the information below to properly turn the transmitter ON (OPERATION mode).
1. Place a charged battery in the transmitter. The charge must be done following the instructions of the
Battery Chargers' Manual.
2. Turn the contact key.
3. Push and pull out the STOP button.
LED will flash orange-green pulse. If the transmitter has LCD, it displays the identification of the
machine and battery level (only if it has been pre-programmed).
Danfoss | December 2018BC292358159566en-000101 | 7
User Manual
T70 1 ATEX Transmitter
Technical description
4. Press the start button. The green LED will now light to indicate the transmitter is transmitting. Once
the Tx is connected, press any maneuver button and its corresponding relay will be activated. Check
to make sure all other maneuvers work in a coherent way with the expected movements.
This product is designed for use in an industrial environment that may shorten the product's lifespan. Use
these tips to maximize the lifespan of the product.
Use the hook/belt provided with the transmitter to prevent the transmitter from falling
•
Do not clean the transmitter with solvents or pressurized water; use a damp cloth or soft brush for
•
cleaning
If the push buttons show signs of deterioration, contact the Authorized Technical Service for repair
•
Check if the battery contacts are correct, otherwise replace them.
•
Ensure that the product is supplied with AAA alkaline batteries or has a rechargeable battery
•
Be sure to recharge or replace battery regularly
•
T70 1 ATEX troubleshooting
The transmitter has status monitoring LED's which help identify irregularities. The most common signals
are contained in the table below:
Color and frequencyPulse frequencyDescriptionAction
Green | continuousWorkingOperate
Green | slow pulsesLatency; no action has been taken for some timePress START to return to operation
Red | slow pulsesLow battery signalReplace or recharge battery
Red | fast pulsesEEPROM module missing or corruptCheck EEPROM and reprogram if
Red | double pulsesA maneuver is activated at transmitter start up process;
may indicate hardware damage if no order is active
Red | continuousGeneral hardware failureReplace transmitter
mode
necessary
Release maneuver or replace
transmitter if necessary
Danfoss | December 2018BC292358159566en-000101 | 9
User Manual
T70 1 ATEX Transmitter
Charger and battery
CB70 and BT06K specifications
CB70 battery charger
SpecificationValue
Standard AC power supply230 Vca ± 10%, 50
Optional AC power supply115 Vca, 60 Hz
DC power supplyFrom 10.5 V to 35V
BT06K ATEX battery
SpecificationValue
Voltage4.8 V
Capacity500 mAh NiMH
Charging temperatureFrom 0° to 45° C
Discharge temperatureFrom -20° to 50° C
Charging modeFast (<2h) and intelligent
Weight70.3 g
The battery is protected by an internal fuse.
Setting up the CB70 battery charger
Use the information below to properly set up the CB70 batter charger.
The battery charger has two charging compartments that can simultaneously charge two batteries.
1. Connect the charger to a power source using the cable supplied.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Products we offer:
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
DCV directional control
•
valves
Electric converters
•
Electric machines
•
Electric motors
•
Hydrostatic motors
•
Hydrostatic pumps
•
Orbital motors
•
PLUS+1® controllers
•
PLUS+1® displays
•
PLUS+1® joysticks and
•
pedals
PLUS+1® operator
•
interfaces
PLUS+1® sensors
•
PLUS+1® software
•
PLUS+1® software services,
•
support and training
Position controls and
•
sensors
PVG proportional valves
•
Steering components and
•
systems
Telematics
•
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electric components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market as well as the
marine sector. Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you and other
customers around the world speed up system development, reduce costs and bring vehicles
and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile
electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also
provide you with comprehensive global service for all of our components.
Local address:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.