Danfoss S7 PVE O Operating guide [ar]

User Manual
PLUS+1® Compliant
S7 PVE O Function Block
www.danfoss.com
User Manual
Revision history Table of revisions
Date Changed Rev
July 2021 Corrected the Output Configuration instructions. 0102
January 2018 First edition 0101
2 | © Danfoss | July 2021 AQ24408648537600en-000102
User Manual

Contents

S7_PVE_O Function Block
Inputs....................................................................................................................................................................................................4
Function Block Parameter Values...............................................................................................................................................4
Outputs................................................................................................................................................................................................ 4
Fault Logic...........................................................................................................................................................................................5
Function Block Connections.........................................................................................................................................................5
Legacy MC Controller—Output Configuration..................................................................................................................... 6
Configure the MFOut.................................................................................................................................................................6
Configure the DigOut................................................................................................................................................................7
SC and Non-Legacy MC Controller—Output Configuration............................................................................................ 8
Configure the MFOut.................................................................................................................................................................8
Configure the DigOut................................................................................................................................................................9
©
Danfoss | July 2021 AQ24408648537600en-000102 | 3
User Manual

S7_PVE_O Function Block

This function block controls the output of a Danfoss Series 7 PVEO electrical actuator.
The PVEO actuator provides on and off control of valves.

Inputs

Inputs to the function block are described.
Input Type Range Description Enable BOOL T/F Enables and disables Output A and Output B.
T: Enables Output A and Output B. F: Disables Output A and Output B.
Fdbk A BUS —— Input for the Status bus that reports the status of the output that is used by the function block’s Output A.
Each output has a Status bus (available through the Input bus) that reports on its status.
Fdbk B BUS —— Input for the Status bus that reports on the status of the output that is used by the function block’s Output B.
Each output has a Status bus (available through the Input bus) that reports on its status.
Input A BOOL T/F Controls Output A.
T: Turn on Output A. F: Turn off Output A.
Input B BOOL T/F Controls Output B.
T: Turn on Output B. F: Turn off Output B.

Function Block Parameter Values

The function block's operating characteristics are set by para bus input signals.
Input Type Range Description Flt_Det BOOL T-F Enables fault detection based on overload/open pin status.
T—Enable fault detection. F—Disable fault detection.

Outputs

Outputs of the function block are described.
Item Type Range Description Fault U16 —— Reports the faults of the function block.
Output A BUS —— Controls the flow of hydraulic pressure to work port A on the PVEO actuator.
T—Flow from the pressure inlet to work port A. F— No flow from the pressure inlet to work port A.
Output B BUS —— Controls the flow of hydraulic pressure to work port B on the PVEO actuator.
T—Flow from the pressure inlet to work port B. F— No flow from the pressure inlet to work port .
4 | © Danfoss | July 2021 AQ24408648537600en-000102
User Manual
S7_PVE_O Function Block

Fault Logic

This topic describes how fault logic indicates problems and causes of problems, as well as solutions to problems.
The following table shows how:
The Fault output indicates fault conditions.
Fault conditions set both Output A and Output B to F.
Condition Fault Output A Output B
Block is OK. 0x0000 T or F. T or F. Output A or Output B is short circuited. 0x8008 F. F. Both Input A and Input B are T. 0x8010 F. F.
Once a fault condition clears, both Input A and Input B must first return to F before Output A and
Output B return to normal T/F operation.

Function Block Connections

Connections you can make with the function block are described.
Function Block Connections PVE_O
Item Description
1 Enables and disables Output A and Output B. 2 Inputs the status of the output that is used by Output A. 3 Inputs the status of the output that is used by Output B. 4 Controls Output A. 5 Controls Output B. 6 Outputs function block faults. 7 8
©
Danfoss | July 2021 AQ24408648537600en-000102 | 5
Turns the flow of hydraulic pressure on and off to work port A on the PVEO actuator. Turns the flow of hydraulic pressure on and off to work port B on the PVEO actuator.
User Manual
S7_PVE_O Function Block

Legacy MC Controller—Output Configuration

Follow the instructions in this section to route the Output A and Output B from the function block to an MFOut or a DigOut on legacy MC controllers.

Configure the MFOut

Configure the multi-function output signal for the function block.
1. In the GUIDE template, enter the Outputs page.
2. Enter the MFOut that receives the function block’s output.
3. Delete the wires to DigOut and PinConfig.
6 | © Danfoss | July 2021 AQ24408648537600en-000102
User Manual
S7_PVE_O Function Block

Configure the DigOut

Configure the digital output signal for the function block.
1. In the GUIDE template, enter the Outputs page.
2. Enter the DigOut that receives the function block’s output.
3. Make the changes that are shown in the following figure.
©
Danfoss | July 2021 AQ24408648537600en-000102 | 7
User Manual
S7_PVE_O Function Block

SC and Non-Legacy MC Controller—Output Configuration

Follow the instructions in this section to route the Output A and Output B of the function block to an MFOut or a DigOut on SC controllers and non-legacy MC controllers.

Configure the MFOut

Configure the multi-function output signal for the function block.
1. In the GUIDE template, enter the Outputs page.
2. Enter the MFOut that receives the function block’s output.
3. Make the changes that are shown in the following figure.
8 | © Danfoss | July 2021 AQ24408648537600en-000102
User Manual
S7_PVE_O Function Block

Configure the DigOut

Configure the digital output signal for the function block.
1. In the GUIDE template, enter the Outputs block.
2. Enter the page that receives the function block’s output.
3. Make the changes shown in the following figure.
©
Danfoss | July 2021 AQ24408648537600en-000102 | 9
Danfoss Power Solutions GmbH & Co. OHG
Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0
Danfoss Power Solutions ApS
Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222
Danfoss Power Solutions (US) Company
2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000
Danfoss Power Solutions Trading (Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 2080 6201
Products we offer:
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Cartridge valves
DCV directional control
valves Electric converters
Electric machines
Electric motors
Gear motors
Gear pumps
Hydraulic integrated
circuits (HICs) Hydrostatic motors
Hydrostatic pumps
Orbital motors
PLUS+1® controllers
PLUS+1® displays
PLUS+1® joysticks and
pedals PLUS+1® operator
interfaces PLUS+1® sensors
PLUS+1® software
PLUS+1® software services,
support and training Position controls and
sensors PVG proportional valves
Steering components and
systems Telematics
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electric components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market as well as the marine sector. Building on our extensive applications expertise, we work closely with you to ensure exceptional performance for a broad range of applications. We help you and other customers around the world speed up system development, reduce costs and bring vehicles and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide you with comprehensive global service for all of our components.
Local address:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
©
Danfoss | July 2021 AQ24408648537600en-000102
Loading...