Danfoss RZ1, RZ1-HP User Manual

Z-Wave Electronic
Radio-Frequency Receivers
(1-Channel)
RZ1 and RZ1-HP
User Guide
Danfoss Heating
MAKING MODERN LIVING POSSIBLE
RZ1 AND RZ1HP
2
For a large print version of these instructions please call Marketing on 0845 121 7400.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
GB
Danfoss Heating
3
GB
Thank you for buying a Danfoss product
RZ1 AND RZ1HP
4
Index
1.0 What is Z Wave? .................................................................................................................................. 5
2.0 Operating Modes.............................................................................................................................. 5
3.0 Initial Start Up....................................................................................................................................... 6
4.0 Understanding your RZ1 ...........................................................................7
5.0 Manual Override ...........................................................................................8
6.0 Factory Reset ..................................................................................................9
7.0 Z-Wave s
upported and controlled classes
...........................................9
8.0 Glossary ..........................................................................................................10
RZ1 and RZ1-HP
Z-Wave Electronic Radio Frequency Receiver (1-Channel)
GB
Danfoss Heating
5
GB
1.0 What is Z Wave?
The RZ1 unit has two operating modes; PROGRAMME Mode: used to configure and set-up the RZ1 by the installer. NORMAL OPERATION Mode: should be set in this mode to allow the RZ1 to work correctly, once installed into system.
The RZ1 can act as a Z-Wave network primary, or secondary controller within a network.
Z wave is an ideal solution for installations of all kinds where a wired heating solution is undesirable or not possible. Using 2 way communication each component of the system can ‘talk’ to each other creating a network of Z-Wave enabled devices. In a domestic heating system this can consist of as little as a wireless thermostat and a wireless receiver up to an entire home controlled using Z-Wave technology. Everything from lighting, burglar alarms, home entertainment systems and many more can be controlled using Z-Wave.
Look for the Z-Wave logo on products to ensure compatibility with other Z-Wave devices.
2.0 Operating Modes
RZ1 AND RZ1HP
6
GB
3.0 Initial Startup
On initial startup the RZ1 will start up in one of two modes with the PROG LED indicating which mode it is in.
• PROG LED continuously ON GREEN: The unit is in a READY STATE. This will be the default startup state for the RZ1 if it was
supplied with an RET BZ.
• PROG LED slowly flashing GREEN: The unit is in RESET STATE and has no previous bindings/devices associated with it – the RZ1 is ready for inclusion into an existing system or to be the base station in a new system. This will be the default startup state for the RZ1 if it has been purchased individually. To establish a link between the RZ1 and another product please see section 4 of the installer manual.
If on power up you have the PROGRAMME LED illuminated in any other way, proceed to page 9 to perform a full reset.
When the RZ1 is in the READY or the RESET STATE the CHANNEL LEDs will be in one of the following modes:
Red Channel LED flashing quickly: The channel is pre-bound to a controller and is waiting for communication from the associated device. Once the remote device communicates with the RZ1 the LED will either go out indicating there is no demand from the remote unit, or turn green to indicate the output is active.
Red Channel LED on continuous: No device is bound to the channel. In this situation, please see section 4 of the installer guide for details on establishing a link with required remote device such as an RET-BZ.
Danfoss Heating
7
GB
4.0 Understanding your RZ1
The RZ1 receiver unit uses a combination of coloured LEDs to indicate the current operating mode/output status. For the purpose of this document the indicator lights will be split into two distinct groups; CHANNEL LEDs and PROGRAMME LED. More information is listed below together with explanations of each of the LED colour states.
Programme LED
Channel LED
Programme LED
Off Awaiting Bind/Unbind button press request Green Normal Run Mode Green (slow flash) Factory Reset State Red Programme Mode Red (slow flash) Binding/association in progress Orange Primary controller shift mode enabled Orange (fast flash) Failed to bind
Channel LED(s) - Programme Mode
Off Channel Bound/Associated Red Channel not Bound/Associated
Red (slow flash) Channel in process of being
bound/associated
Channel LED(s) - Run Mode
Off Output OFF Green Output ON Red Channel not Bound Red (fast flash) Channel Bound but no communication Red (slow flash) Channel manually overridden to an OFF state Green/Orange
(slow flash)
Channel manually overridden to an ON state
RZ1 AND RZ1HP
8
5.0 Manual Override
To manually override a channel on the RZ1 receiver you need to press the associated channel button. Depending on the output state at time of override the Channel LED will operate in a set manner:
If the channel is already bound/associated with a wireless device:
If channel output is ON and needs to be manually switched OFF: Press the channel button, the channel will switch off and the Channel LED will flash RED slowly to indicate it has been manually overridden into the off state.
It the channel output is OFF and needs to be manually switched on: Press the channel button, the channel will switch on and the Channel LED will flash GREEN/ORANGE.
If the channel is not bound/associated with a wireless device:
If the channel output is on and needs to be manually switched off: The channel LED will show RED to indicate output is off.
If the channel output is off and needs to be manually switched on: The channel LED will be ORANGE to show that it is not associated with a device but is overridden manually to the on state.
Manual override is cancelled if at any time the channel button is pressed again, or the RZ1 receives a signal from an associated device to counteract the override.
If a service interval capable unit is connected to the RZ1 receiver, the manual override button may be disabled.
GB
Danfoss Heating
9
GB
6.0 Factory Reset
If for any reason you need to return the RZ1 unit to its factory reset state, or you need to wipe all network information from the unit it is advisable to perform a factory reset.
1. Press PROG to place the receiver in PROGRAMME mode (Red LED illuminated continuously).
2. Press and hold CH1 button for at least 15 seconds.
3. The PROG LED will flash rapidly orange and green. Press and hold down the PROGRAMME button for at least 15 seconds.
4. If reset was successful, the channel LEDs will show as RED and the PROG LED will flash slowly green to indicate that the unit is now in its factory reset state.
* if after step 1, the PROG button is not held down within 30 seconds, the unit will return to its previous state and the full reset will not have been applied.
Basic Support
Binary switch Support
Association Control
Multi-instance Support
Multi-instance Association Control
Multi-command Control and Support
Multi-channel Control and Support
Protection Vn2 Support
Version Support
Wakeup Control
Thermostat Set Point Support
7.0 Z-Wave supported and controlled classes
GB
RZ1 AND RZ1HP
10
Binding The act of linking a remote wireless unit (i.e.
thermostat or time controller) to the RZ1 receiver channel
Channel The output of the RZ1 unit. RZ1 has one
channel. This channels can be used to control a device that requires switching on.
Include/Exclude Initiator Button
On every Z-Wave product there will be a button or process to tell the device to send out a request to join or leave an existing or new network.
LED Light Emitting Diode. The RZ1 has tri-colour
LEDs to indicate the different states the control can be in.
Programme State The RZ1 is ready to include or exclude other
Z-Wave compatible devices from the network.
Ready State When the RZ1 is in ready state the GREEN
PROG LED is lit and the device is waiting for instructions to switch on or off its output(s).
Reset State In the Reset State the RZ1 is reset back to
factory defaults and is ready to either be added into an existing network as a secondary controller or to be used to create a network as a primary controller.
Z-Wave A wireless communication protocol designed
for low-power and low-bandwidth appliances, such as home automation and sensor networks
8.0 Glossary
GB
Danfoss Heating
11
SUC Static Update Controller - This is a secondary
controller that acts as a back-up store of the network routings. The SUC can be used as a new primary network controller should the original primary malfunction.
SIS SUC ID Server - This is a SUC controller which
has been promoted by the network to become the ID server. Any controller in the network can include new nodes to the network, not just the primary device, with a SIS in the network - This increases the functionality of the network.
Part No. RZ1v03_User
Danfoss Randall Ltd.
Ampthill Road Bedford MK42 9ER
Tel: 0845 1217 400 Fax: 0845 1217 515 Email: danfossrandall@danfoss.com Website: www.danfoss-randall.co.uk
Loading...