Danfoss RAW-K 5013 Data sheet

Data Sheet
Thermostatic Radiator Sensor, Type RAW-K 5013
Application
The RAW series is a programme of radiator thermostats which covers all central and district heating systems.
RAW-K radiator thermostats are designed for use in 2-pipe domestic heating systems.
Quality
Coefficient de Variation Temporelle
Features - Thermostatic valves functioning
Thermostatic sensors RAW-K 5013 are manufactured to the highest standards, and are approved to the European stand­ard EN 215.
RAW-K 5013: Vt = 0,2 K
autonomously without auxiliary power
- Locking and limitation of the sensors temperature setpoint are carried out using the limiter tabs
The RAW-K sensor incorporates a frost pro­tection setting for maximum user flexibility, and provides also the option to limit the temperature range.
The RAW-K design is particularly robust, with both End-Stop strength limits and sensor bending force limits being substantially above the requirements of the European Standard EN 215.
All Danfoss radiator thermostats are manu­factured in factories, assessed and certified against ISO 9001and ISO 14001.
- Comfort in heating and very good recovery (energy saving)
- Aesthetic that integrates with any interior (Colour: RAL 9016)
Ordering and Specifications
RAW-K 5013 Built-in sensor RAL 9016 8-28 °C 013G5013
1) Xp = 2K (the valve closes at 2 °C higher room temperature)
VDLTC102 © Danfoss 01/2017 1
Version Colour Setting range 1) Code No.
10 14 18 22 26 30 °C
1
2
• • • 3 • • • 4
5
8 12 16 20 24 28 °C
Datasheet Thermostatic Radiator Sensor, Type RAW-K 5013
A
B
Setting the Temperature
* = Frost protection setting
Mounting
The required room temperature is set by turning the thermostat handle. The tempe­rature scale shows the correlation between scale values and the room temperature. The temperature values stated are for guidance only as the obtained room temperature will often be influenced by installation conditi­ons.
Mount the sensor onto the valve by tightening the nut with a wrench.
The temperature scale is stated according to European standards at Xp = 2K. This means that the radiator thermostat close at a sensor temperature which is 2°C higher than stated on the temperature scale.
Limiting the Adjustment Range
VDLTC102 © Danfoss 01/2017 2
The thermostat's two limiter tabs can be used for simply limiting of the min. and max. range.
Example: If 4 should be max. setting, turn the thermostat handle to the max. stop (A) and press and hold right tab (B) while turning the thermo­stat to 4. Now release tab.
With the left tab the lower temperature must be turned to other position.
Unauthorized adjustment of the limit settings can be prevented by means of blocking pins ( Accessory No . 013G5199 ).
These can only be removed with the Danfoss special tool ( Order No. 013G1236 ).