Danfoss RAW-K 5013 Data sheet

Data Sheet

Thermostatic Radiator Sensor, Type RAW-K 5013

Application

The RAW series is a programme of radiator thermostats which covers all central and district heating systems.

RAW-K is a self-acting proportional controller with a small P-band.

RAW-K radiator thermostats are designed for use in 2-pipe domestic heating systems.

Quality

 

Thermostatic sensors RAW-K 5013 are

 

 

manufactured to the highest standards,

 

 

and are approved to the European stand-

 

 

ard EN 215.

Coefficient de Variation

RAW-K 5013: Vt = 0,2 K

Temporelle

 

 

Features

-

Thermostatic valves functioning

 

 

autonomously without auxiliary power

 

-

Locking and limitation of the sensors

 

 

temperature setpoint are carried out using

 

 

the limiter tabs

The RAW-K sensor incorporates a frost protection setting for maximum user flexibility, and provides also the option to limit the temperature range.

The RAW-K design is particularly robust, with both End-Stop strength limits and sensor bending force limits being substantially above the requirements of the European Standard EN 215.

All Danfoss radiator thermostats are manufactured in factories, assessed and certified against ISO 9001and ISO 14001.

-Comfort in heating and very good recovery (energy saving)

-Aesthetic that integrates with any interior (Colour: RAL 9016)

Ordering and

 

 

 

 

 

 

Version

Colour

Setting range 1)

Code No.

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

RAW-K 5013

Built-in sensor

RAL 9016

8-28 °C

013G5013

1) Xp = 2K (the valve closes at 2 °C higher room temperature)

VDLTC102 © Danfoss 01/2017

1

Danfoss RAW-K 5013 Data sheet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Datasheet

Thermostatic Radiator Sensor, Type RAW-K 5013

 

 

 

 

 

Setting the Temperature

* = Frost protection setting

10

14

18

22

26

30

°C

 

 

 

 

 

 

1

2 • • • 3 • • • 4

5

 

8

12

16

20

24

28

°C

The required room temperature is set by turning the thermostat handle. The temperature scale shows the correlation between scale values and the room temperature. The temperature values stated are for guidance only as the obtained room temperature will often be influenced by installation conditions.

Mounting

Mount the sensor onto the valve by

 

tightening the nut with a wrench.

Limiting the Adjustment

Range

AB

The temperature scale is stated according to European standards at Xp = 2K. This means that the radiator thermostat close at a sensor temperature which is 2°C higher than stated on the temperature scale.

The thermostat's two limiter tabs can be used for simply limiting of the min. and max. range.

Example: If 4 should be max. setting, turn the thermostat handle to the max. stop (A) and press and hold right tab (B) while turning the thermo­ stat to 4. Now release tab.

With the left tab the lower temperature must be turned to other position.

Unauthorized adjustment of the limit settings can be prevented by means of blocking pins ( Accessory No . 013G5199 ).

These can only be removed with the Danfoss special tool ( Order No. 013G1236 ).

VDLTC102 © Danfoss 01/2017

2

Loading...
+ 2 hidden pages