Danfoss RAS-C Data sheet

Data Sheet
RAS-C2 Range
Radiator Thermostats for Domestic 2-Pipe Systems
Application
System
RAS-C² radiator thermostats are designed for use in 2-pipe domestic heating systems.
All RAS-C² Combi Packs comprise of a RA-FS angled or straight pattern bi-directional valve and a RAS-C2 sensor designed for 2-pipe heating systems.
Combi Packs are also available with a RLV-D lockshield valve or drain-o tailpiece.
The valves have a ½” BSP (R½”) tail piece connection to the radiator and are available with 15mm, 10mm or 8mm compression tting or an elbow with 10mm push-t tting to connect the valve to the pipe work.
The valve bodies are reversible and bi-directional and include a ow-selectable feature to ensure trouble free installation without any risk of water hammer. For optimum performance, Danfoss recommend the sensor be mounted horizontal where at all possible.
The valve is supplied with a protective cap, which can be used for manual regulation during the construction phase. The cap must not be used as a manual shut of device.
RAS-C² sensors incorporate a “Frost Protection” setting and a “Positive O” feature for maximum user exibility. Temperature range is from 8°C to 28°C.
© Danfoss Climate Solutions | 02/2022 | AI000086402453en-010803
1
Data Sheet RAS-C2 Range - Radiator Thermostats for Domestic 2-Pipe Systems
Ordering Details
Valve bodies and RAS-C2 thermostatic sensors supplied complete in Combi-pack form
Tem p.
Symbol Typ e Comprising
range °C,
Xp = 2 K
RAS-C² Combi 6050
RAS-C² Combi 6055
RAS-C² Combi 6058
RAS-C² Combi 6060
RAS-C² Radiator Pack 6005
RAS-C² Radiator Pack 6006
15 mm angle valve body and thermostatic sensor
10 mm angle valve body and thermostatic sensor
8 mm angle valve body and thermostatic sensor
Angle valve body, RAS-C
2
thermostatic sensor and elbow with 10 mm push-t tting
15 mm angle valve body, lockshield valve and thermostatic sensor
10 mm angle valve body, lockshield valve and thermostatic sensor
8-28 013G6050
8-28 013G6055
8-28 013G6058
8-28 013G6060
8-28 013G6005
8-28 013G6006
Code No.
RAS-C² Radiator Pack 6008
RAS-C² Radiator Pack 6007
RAS-C² Radiator Pack 6009
RAS-C² Radiator Pack 6025
RAS-C² Combi Pack 6051
RAS-C² Combi Pack 6056
RAS-C² Radiator Pack 6003
8 mm angle valve body, lockshield valve and thermostatic sensor
Angle valve body, lockshield valve, thermostatic sensor and elbows with 10 mm push-t tting
15 mm angle valve body, lockshield valve, thermostatic sensor and drain-o tailpiece with 10 mm push-t tting
15 mm angle valve body, lockshield valve, thermostatic sensor and drain-o tailpiece with 15 mm push-t tting
15 mm bi-directional straight valve body and thermostatic sensor, 15 mm ttings
8/10 mm bi-directional straight valve body and thermostatic sensor, 8/10 mm ttings
15 mm bi-directional straight valve body, lockshield valve, therm­ostatic sensor, 15 mm ttings
8-28 013G6008
8-28 013G6007
8-28 013G6009
8-28 013G6025
8-28 013G6051
8-28 013G6056
8-28 013G6003
RAS-C² Radiator Pack 6004
2
© Danfoss Climate Solutions | 02/2022 | AI000086402453en-010803
8/10 mm bi-directional straight valve body, lockshield v alve, therrmo
-static sensor, 8/10 mm fittings
8-28 013G6004
Data Sheet RAS-C2 Range - Radiator Thermostats for Domestic 2-Pipe Systems
RAS-C² sensors supplied in a separate box
Typ e Sensor (Max. sensor temperature 60°C) Temp. range °C (Xp = 2 K) Code No.
RAS-C2Built-in (includes positive shut-o) 8 - 28 013G6040
Specication
RA-FS angle valves supplied in separate boxes
Connection
Typ e
RA-FS 15
1) 3)
RA-FS 15
3)
with pusht elbow
1)
RA-FS valves must only be used with RAS-C2 or RAS-D sensors.
2)
As with any device which imposes a pressure drop in the system, noise may occur under certain ow/
Design
Inlet
Rev.
Angle15mm
Rev.
8/10mm1/2”
Angle
Rev.
Angle10mm
Outlet
kv-value (m³/h at Δp = 1
bar), P-band (K)
0.5 1.0 2.0 3.0 k
1/2” BSP
BSP
0.13 0.27 0.50
1/2” BSP
0.64
Max. pressure
0.73
vs
Work. press.
Di.
press.
bar bar bar °C
10 0.6 16 12 0
3 0.6 6 92
Tes t
press.
Max.
temp.
Code No.
013G 6281
013G6283
pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed 45 kPa (0.45 bar). The dierential pressure can be reduced using Danfoss automatic by-pass valve AVDO.
3)
Only available in Combi packs.
The push-t tting is suitable for 10 mm copper pipes manufactured in accordance to BS 2871
Always use plastic pipe inserts of the same brand
as the pipe used. part 1 / BS EN 1057 : 1996 and suitable for 10 mm polybuthelene (PB) including Hep2O, Polyplumb, OsmaGold and 10 mm cross linked polyethylene (PEX) pipes made in accordance to BS 7291 part 1 : 1990 or part 3 : 1990.
Approved to EN 215
Quality Standards
All Danfoss RAS-C2² sensors and RA-FS valves are manufactured to the highest standards and are approved to the European standard EN 215, which supersedes BS 6284, 1983.
All Danfoss radiator thermostats and valves are manufactured in factories, assessed and certied by BVC (Bureau Veritas Certication) against ISO 9001 / BS 5750.
© Danfoss Climate Solutions | 02/2022 | AI000086402453en-010803
3
Loading...
+ 5 hidden pages