Data Sheet
RAS-C2 Range
Radiator Thermostats for Domestic 2-Pipe Systems
Application
RAS-C² radiator thermostats are designed for use in 2-pipe domestic heating systems.
All RAS-C² Combi Packs comprise of a RA-FS angled or straight pattern bi-directional valve and a RAS-C2 sensor designed for 2-pipe heating systems.
Combi Packs are also available with a RLV-D lockshield valve or drain-off tailpiece.
The valves have a ½” BSP (R½”) tail piece connection to the radiator and are available with 15mm, 10mm or 8mm compression fitting or an elbow with 10mm push-fit fitting to connect the valve to the pipe work.
The valve bodies are reversible and bi-directional and include a flow-selectable feature to ensure trouble free installation without any risk of water hammer. For optimum performance, Danfoss recommend the sensor be mounted horizontal where at all possible.
The valve is supplied with a protective cap, which can be used for manual regulation during the construction phase. The cap must not be used as a manual shut of device.
RAS-C² sensors incorporate a “Frost Protection” setting and a “Positive Off” feature for maximum user flexibility. Temperature range is from 8°C to 28°C.
System
© Danfoss Climate Solutions | 02/2022 | AI000086402453en-010803 |
1 |
Data Sheet |
RAS-C2 Range - Radiator Thermostats for Domestic 2-Pipe Systems |
||||
Ordering Details |
Valve bodies and RAS-C2 thermostatic sensors supplied complete in Combi-pack form |
|
|||
|
|
|
|
Temp. |
|
|
Symbol |
Type |
Comprising |
range °C, |
Code No. |
|
|
|
|
Xp = 2 K |
|
|
|
|
|
|
|
|
|
RAS-C² Combi |
15 mm angle valve body and |
8-28 |
013G6050 |
|
|
6050 |
thermostatic sensor |
||
|
|
|
|
||
|
|
|
|
|
|
|
|
RAS-C² Combi |
10 mm angle valve body and |
8-28 |
013G6055 |
|
|
6055 |
thermostatic sensor |
||
|
|
|
|
||
|
|
|
|
|
|
|
|
RAS-C² Combi |
8 mm angle valve body and |
8-28 |
013G6058 |
|
|
6058 |
thermostatic sensor |
||
|
|
|
|
||
|
|
|
|
|
|
|
|
RAS-C² Combi |
Angle valve body, RAS-C2 |
|
013G6060 |
|
|
thermostatic sensor and elbow |
8-28 |
||
|
|
6060 |
|||
|
|
with 10 mm push-fit fitting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RAS-C² |
15 mm angle valve body, |
|
013G6005 |
|
|
Radiator Pack |
lockshield valve and |
8-28 |
|
|
|
6005 |
thermostatic sensor |
|
|
|
|
|
|
|
|
|
|
RAS-C² |
10 mm angle valve body, |
|
013G6006 |
|
|
Radiator Pack |
lockshield valve and |
8-28 |
|
|
|
6006 |
thermostatic sensor |
|
|
|
|
|
|
|
|
|
|
RAS-C² |
8 mm angle valve body, |
|
013G6008 |
|
|
Radiator Pack |
lockshield valve and |
8-28 |
|
|
|
6008 |
thermostatic sensor |
|
|
|
|
|
|
|
|
|
|
RAS-C² |
Angle valve body, lockshield |
|
013G6007 |
|
|
Radiator Pack |
valve, thermostatic sensor and |
8-28 |
|
|
|
6007 |
elbows with 10 mm push-fit fitting |
|
|
|
|
|
|
|
|
|
|
RAS-C² |
15 mm angle valve body, |
|
|
|
|
lockshield valve, thermostatic |
|
013G6009 |
|
|
|
Radiator Pack |
8-28 |
||
|
|
sensor and drain-off tailpiece |
|||
|
|
6009 |
|
|
|
|
|
with 10 mm push-fit fitting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RAS-C² |
15 mm angle valve body, |
|
|
|
|
lockshield valve, thermostatic |
|
013G6025 |
|
|
|
Radiator Pack |
8-28 |
||
|
|
sensor and drain-off tailpiece |
|||
|
|
6025 |
|
|
|
|
|
with 15 mm push-fit fitting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RAS-C² |
15 mm bi-directional straight |
|
013G6051 |
|
|
Combi Pack |
valve body and thermostatic |
8-28 |
|
|
|
6051 |
sensor, 15 mm fittings |
|
|
|
|
|
|
|
|
|
|
RAS-C² |
8/10 mm bi-directional straight |
|
013G6056 |
|
|
Combi Pack |
valve body and thermostatic |
8-28 |
|
|
|
6056 |
sensor, 8/10 mm fittings |
|
|
|
|
|
|
|
|
|
|
RAS-C² |
15 mm bi-directional straight |
|
013G6003 |
|
|
Radiator Pack |
valve body, lockshield valve, therm- |
8-28 |
|
|
|
6003 |
ostatic sensor, 15 mm fittings |
|
|
|
|
|
|
|
|
|
|
RAS-C² |
8/10mmbi-directionalstraight |
|
013G6004 |
|
|
Radiator Pack |
valvebody,lockshieldvalve, therrmo |
8-28 |
|
|
|
6004 |
-staticsensor,8/10mmfittings |
|
|
|
|
|
|
|
|
2 |
© Danfoss Climate Solutions | 02/2022 | AI000086402453en-010803 |
Data Sheet |
RAS-C2 Range - Radiator Thermostats for Domestic 2-Pipe Systems |
|||||||||||||||
|
RAS-C² sensors supplied in a separate box |
|
|
|
|
|
|
|
|
|
||||||
|
Type |
|
Sensor (Max. sensor temperature 60°C) |
|
Temp. range °C (Xp = 2 K) |
Code No. |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RAS-C2 |
|
Built-in (includes positive shut-off) |
|
|
|
|
8 - 28 |
|
013G6040 |
||||||
Specification |
RA-FS angle valves supplied in separate boxes |
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Connection |
kv-value (m³/h at Δp = 1 |
Max. pressure |
|
|
||||||||
|
|
|
|
|
bar), P-band (K) |
|
|
Max. |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Type |
Design |
|
|
|
|
|
|
|
|
Work. |
Diff. |
Test |
temp. |
Code No. |
|
|
|
|
|
Inlet |
Outlet |
0.5 |
1.0 |
2.0 |
3.0 |
kvs |
press. |
press. |
press. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
bar |
bar |
bar |
°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rev. |
15 |
1/2” |
|
|
|
|
|
|
|
|
|
|
013G6281 |
|
RA-FS 15 |
|
Angle |
mm |
BSP |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
0.6 |
16 |
120 |
|
||||
|
1) 3) |
|
Rev. |
8/10 |
1/2” |
|
|
|
|
|
|
013G6283 |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
Angle |
mm |
BSP |
0.13 |
0.27 |
0.50 |
0.64 |
0.73 |
|
|
|
|
||
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
||||||
|
RA-FS 15 |
|
Rev. |
10 |
1/2” |
|
|
|
|
|
|
|
|
|
|
|
|
3) with |
|
|
|
|
|
|
|
3 |
0.6 |
6 |
92 |
|
|||
|
pushfit |
|
Angle |
mm |
BSP |
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
elbow |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1)RA-FS valves must only be used with RAS-C2 or RAS-D sensors.
2)As with any device which imposes a pressure drop in the system, noise may occur under certain flow/ pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed 45 kPa (0.45 bar). The differential pressure can be reduced using Danfoss automatic by-pass valve AVDO.
3)Only available in Combi packs.
|
The push-fit fitting is suitable for 10 mm copper |
Always use plastic pipe inserts of the same brand |
|
pipes manufactured in accordance to BS 2871 |
as the pipe used. |
|
part 1 / BS EN 1057 : 1996 and suitable for 10 mm |
|
|
polybuthelene (PB) including Hep2O, Polyplumb, |
|
|
OsmaGold and 10 mm cross linked polyethylene |
|
|
(PEX) pipes made in accordance to BS 7291 part |
|
|
1 : 1990 or part 3 : 1990. |
|
Approved to EN 215 |
All Danfoss RAS-C2² sensors and RA-FS |
|
|
valves are manufactured to the highest |
|
|
standards and are approved to the |
|
|
European standard EN 215, which |
|
|
supersedes BS 6284, 1983. |
|
Quality Standards |
All Danfoss radiator thermostats and valves are |
|
|
manufactured in factories, assessed and certified |
|
|
by BVC (Bureau Veritas Certification) against ISO |
|
|
9001 / BS 5750. |
|
© Danfoss Climate Solutions | 02/2022 | AI000086402453en-010803 |
3 |