Danfoss RAE Installation guide

Danfoss Radiator Thermostat RAE
Installation Guide
Fitting the snap-lock sensor
1. Prise the green protec­tive cap off the valve.
2.Offer sensor onto valve ensuring that scale pointer is at top.
Removing the snap-lock sensor
2. Turn sensor to max.
1. prise out antitheft lock with Danfoss tool or a small screwdriver.
setting.
3.Press the sensor firmly onto valve until snap­lock "clicks"
3. Hold outer ring whilst turning inner ring anti­clockwise to release snap-lock mechanism. The sensor can now be separated from the valve.
4. If required firmly press anti-theft lock into inner ring to prevent unauthor­ised removal
Resetting the snap-lock
4. Having removed sensor from valve, ensure sen­sor is set to max.
5. Hold outer ring whilst turning arrow mark on inner ring towards scale pointer until stop.
Adjusting temperature control range
T I II III IIII I
8 12162024 2C
Setting the upper limit:
e.g. III as the highest pos­sible temperature selec­tion:
1. Turn the head to max. position
2. Keep the limiter tab to the right of the black scale pointer pressed down with a small screwdriver.
3. Turn the head round to III and release the tab.
2 3 2 3
I II III IIII I
8 12162024 2C
Setting the lower limit:
e.g. II as the lowest possi­ble temperature selection:
1. Turn the head to min. position.
2. Keep the limiter tab to the left of the black scale pointer pressed down with a small screwdriver.
3. Turn the head to II. You
can now release the tab.