Data Sheet
PLUS+1® Controllers
OX012-010
Mobile Machine Management
The OX012-010 output expansion module is an
element of the flexible, powerful and expandable
PLUS+1® family of mobile machine management
products. Expansion modules provide costeffective
additional I/O to mobile machine control systems.
Product Highlights
Output expansion modules are associated with a
PLUS+1® controller. PLUS+1® GUIDE (Graphical User
Integrated Development Environment) applications
running in the controller write outputs to expansion
module pins as if the pins are physically located on
the controller. Pin properties are configured in the
controller’s GUIDE application.
PLUS+1® compliance eliminates need for the system
designer to write CAN transmit and receive messages
in both the controller and associated expansion
modules.
Application Development
Users configure expansion modules using PLUS+1
GUIDE. This Microsoft® Windows®-based
development environment features a user-friendly,
field proven, icon-based graphical programming tool,
application downloader, and service/diagnostic tool.
Features
•
12 pin DEUTSCH DTM connector
•
9 to 36 Vdc power supply, monitored
internally
•
1 CAN 2.0B port
•
3 mounting alternatives: stack, end, or
side
•
CE compliant
Outputs
6 universal (PWMOUT/DOUT/PVGOUT)
outputs that are user-defined as either:
®
•
Digital: (3 A), configurable as a source or
sink;
•
PWM: (30 to 4000 Hz) configurable as
open or closed loop with current
control;
•
Analog voltage: open loop PWM at 4000
Hz.
•
Any PWMOUT/DOUT/PVGOUT can be
used to provide reference power to one
PVG valve.
Comprehensive technical literature is
online at www.danfoss.com
©
Danfoss | June 2017 AI00000015en-001201 | 1
OX012-010 dimensions and pin assignments
114.4 [4.50]
158.2 [6.23]
2 X 25.3 [1.0]
107.0 [4.21]
62.0 [2.44]
35.3 [1.39]
51.6 [2.03]
47.1 [1.85]
144.5 [5.69]
2199A
mm [in]
Caution
This device is not field serviceable. Opening the device housing
will void the warranty.
12 Pin connector
Pin Controller function
C1-P1 Power ground C1-P2 Power supply +
C1-P3 CAN +
C1-P4 CAN C1-P5 CAN shield
C1-P6 PWMOUT/DOUT/PVGOUT
C1-P7 PWMOUT/DOUT/PVGOUT
C1-P8 PWMOUT/DOUT/PVGOUT
C1-P9 PWMOUT/DOUT/PVGOUT
C1-P10 PWMOUT/DOUT/PVGOUT
C1-P11 PWMOUT/DOUT/PVGOUT
C1-P12 Power supply +
Caution
PCB damage may occur. All device power supply + pins must be
connected to battery +.
Specifications
Supply voltage 9 to 36 V
Operating temperature
(ambient)
Storage temperature –40°C to 85°C [–40°F to 185°F]
Programming temperature 0°C to 70°C [ 32°F to 158°F]
IP rating (with mating connector
attached)
EMI/RFI rating 100 V/M
Weight 0.34 kg [0.75 lb]
Vibration IEC 60068-2-64
Shock IEC 60068-2-27 test Ea
Maximum current, sourcing 16 A
Maximum current, sinking 8 A
DC
–40°C to 70°C [–40°F to 158°F]
IP 67
Use care when wiring mating connector. Pinouts listed are for
device pins.
Ordering information
Product part number
OX012-010 10100996
Related products part numbers
CG150 CAN/USB Gateway 10104136
DEUTSCH mating
connector
bag assembly
PLUS+1® GUIDE
single user license
10102025
(16 to 20 AWG)
10101000
10100944
(20 to 24 AWG)
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | June 2017 AI00000015en-001201