Danfoss OLSP Data sheet

Data Sheet

Priority Valve

Type OLSP

Introduction

Danfoss introduce a new priority valve for flanging on gear pumps.

Use and function

The priority valve OLSP 80 is to be used in connection with e.g. Danfoss gear pumps type SNP and steering units type OSPC LS, OSPF LS, OSPD LS and OSPQ LS in load sensing steering systems, where maximum oil flow doesn’t exceed 80 l/min.

OLSP priority valves are to be flanged on gear pumps with outlet ports square flange type 35.

Versions

Load sensing static priority valves

Load sensing static steering units require load sensing static priority valves. Load sensing static steering systems have no oil flow in the LS connection when the steering unit is in neutral position.

Load sensing dynamic priority valves

Load sensing dynamic steering units require load sensing dynamic priority valves. Load sensing dynamic steering systems have a constant oil flow in the LS connection from the priority valve to the steering unit even when the steering unit is in neutral position.

Features

For flanging on pumps directly

Simplified installation

Compact design

Low pressure drop

Optional port connections

Available for both static and dynamic systems

Comprehensive technical literature online at powersolutions.danfoss.com

© Danfoss | Jun 2016

520L0759 | AI00000081en-US0203 | 1

Danfoss OLSP Data sheet

Technical data

Max. pressure on connections

Priority valve

Rated flow to P

Max. pressure on connections

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

P,EF

 

CF

 

LS

 

 

 

 

 

 

 

 

 

 

 

bar

[psi]

bar

[psi]

bar

[psi]

 

 

 

 

 

 

 

 

OLSP 80

80

280

[4060]

240

[3480]

240

[3480]

 

 

 

 

 

 

 

 

Dimensions

OLSP 80

CF G 3/8 w. spot face; 15 mm (0.59 in) deep; x = ø28, max 1.5 mm deep; or

M18 x 1.5 ISO 6149 15 mm (0.59 in) deep, y = ø29, max 1.5 mm deep

EF G 1/2 w. spot face; 15 mm deep; y = ø34, max 1.5 mm deep; or M22 x 1.5 ISO 6149; 15 mm deep; x = ø34, max 1.5 mm deep

LS G 1/4 w. spot face; 12.5 mm deep

M12 x 1.5 ISO 6149; 12.5 mm deep

For details please see Technical Information 11007611

<![if ! IE]>

<![endif]>Ø6.5 [0.26]

 

24.7 [0.972]

Ø24.4 [0.961]

33 [1.30]

1.88 [0.74] deep

<![if ! IE]>

<![endif]>24.7 [0.972]

 

<![if ! IE]>

<![endif]>31.2 [1.228]

<![if ! IE]>

<![endif]>43.5 [1.713]

<![if ! IE]>

<![endif]>38 [1.50]

 

 

84 [3.31]

 

X

Y

32 [1.26]

19.5 [0.768]

38 [1.50]

 

 

 

25 [0.98]

<![if ! IE]>

<![endif]>[0.04]Ø11

20 [0.89] 52 [2.05]

<![if ! IE]>

<![endif]>91 [3.58]

 

LS

<![if ! IE]>

<![endif]>[1.30]

 

<![if ! IE]>

<![endif]>33

CF

EF

 

 

 

24 [0.94]

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2 | © Danfoss | Jun 2016

520L0759 | AI00000081en-US0203