Data sheet
Non return Valve - Danfoss NVD 895
•
Description
Features:
• Operating position: horizontal and vertical
• Minimum occupation of space
• Very low head loss
• For pumping, water supply, general industry
Closing system: double plate with return spring
• Using these check valves on networks
equipped with piston pumps or compressors
is not recommended.
Main Data:
• DN 50 - 400
• kVS 35.7 - 5867 m3/h
• PN 10/16
• Medium:
- Circulation water, drinking water or chilled
glycolic water up to 50 %
• Medium Temperature:
- 10 … 100 °C
• Mounting between flanges PN10/16
• Compliance with Pressure Equipment
Directive 2014/68/EU
• Approvals:
Ordering
Note:
The indicated pressure for the
different categories of fluids
(L1/L2/G1/G2) is under no condition
a guarantee of use.
Therefore, it is essential to validate
the use of products under given
operating conditions.
Dimensions
16
PS (bar)
16
0.5 065B7501
D
Code No.
065B7495
16
DN
50 35.7
65 64.7 15 065B7496
80 116.1 12 065B7497
100 253.3 10 065B7498
125 4 81.8 0.5 065B7499
150 698.4 13 0.5 065B7500
200 1345. 5
250 2249.5 0.5 14 065B7502
300 3098 0.5 11 065B7503
400 5867 - 8 065B7504
DN
50 50 54 60 10 9 1.2
65 65 54 73 129 1.8
80 80 57 89 144 2.9
100 100 64 114 164 3.9
125 12 5 70 141 194 5.8
150 150 76 168 220 8
200 200 95 219 275 14
250 250 108 273 330 22
300 300 143 324 380 34
400 400 191 410 491 83
Kv
(m3/h)
A
(mm)B(mm)C(mm)D(mm)
PN
10/16 16
PFA
(bar)
L1 L2 G1 G2
16
10
Weight
(kg)
© Danfoss | 2019.04 VD.BO.L2.02 | 1
Data sheet Danfoss NVD 895
Design
Pos. Description Material EURO ANSI
Casing DN50-150
1
DN200-400
2 Plates Stainless steel GX 5CrN i19-10 AISI 304
3 Seal EPDM − −
4 Spring Stainless steel X5 CrN iMo17 -12-2 AISI 316
5 Steam Stainless steel X 5Cr NiM o17-12-2 AISI 316
6 Bearing PTFE − −
7 Eye bolt DN>150 Steel XC15 − −
8 Plugs Brass − −
Cast iron + epoxy
Ductile iron + epox y
EN -G JL-2 50
EN-GJS-400.15
ASTM A 48 35 B
ASTM A 536 60-40 -18
Headloss diagram
DN
50
Opening pressure
(mm)
Kv
(m3/h)
35.7 7. 81
65 64.7 6 .81
80 116 .1 4.86
100 253.3 2.49
125 4 81.8 1.68
150 698.4 1. 66
Near 0
200 1345. 5 1.41
250 2249.5 1.23
300 3098 1.35
400 5867 1.2
Direction for use:
• Solid line: Valve completely open
• Dotted line: opening stage of valve
M/CE
15
10
8
7
6
5
4
3
2
1
M/WC
10
8
7
6
5
4
3
2
1.5
1
.8
.7
.6
.5
.4
.3
.2
.15
DN
ζ
80
65
50
100
125
150
200
250
300
400
234 5
8
10
8
6
10
15
20253040506080
30
40
60
15
20
25
80
100
100
150
300
400
600
800
500
250
150
200
300
400
600
800
500
250
1000
1500
2000
2500
2000
3000
2500
1000
1500
3000
4000
5000
6000
8000
10000
© Danfoss | DHS-SRMT/SI | 2019.042 | VD.BO.L2.02
4000
15000
5000
DEBIT M3/H
6000
FLOW GALL
0
20000