Danfoss NVD 805 Data sheet

Data sheet

Non return Valve - Danfoss NVD 805

Description

Features:

Operating position: horizontal and vertical

Minimum occupation of space

Very low head loss

For pumping, water supply, general industry

Closing system: double plate with return spring

Sealing: metal on elastomere seat

Using these check valves on networks equipped with piston pumps or compressors is not recommended.

Main Data:

DN 50 - 600

kVS 39.4 - 11269 m3/h

PN 10/16

Medium:

-Circulation water, drinking water or chilled glycolic water up to 50 %

Medium Temperature:

-10 … 100 °C (EPDM seal), 80 °C (NBR seal)

Mounting between flanges PN10/16

Compliance with Pressure Equipment Directive 2014/68/EU

Flange drilling according to EN1092-2

• Approvals:

Ordering

Note:

The indicated pressure for the different categories of fluids (L1/L2/G1/G2) is under no condition a guarantee of use.

Therefore, it is essential to validate the use of products under given operating conditions.

˝

DN

Kv

PN

PFA

 

 

PS (bar)

 

Code No.

(m3/h)

(bar)

L1

L2

 

G1

G2

 

 

 

 

 

2

50

39.4

 

 

 

 

 

16

 

065B7505

2 ½

65

83

 

 

 

 

 

15

 

065B7506

3

80

138

 

 

16

 

 

12

 

065B7507

4

100

250

 

 

 

 

 

10

16

065B7508

5

125

505

 

 

 

 

 

 

 

065B7509

6

150

891

 

 

13

 

 

 

 

065B7510

8

200

1510

10/16

16

 

16

 

0.5

 

065B7511

10

250

2746

 

 

 

14

065B7512

 

 

 

 

 

 

12

300

3936

 

 

 

 

 

 

11

065B7513

14

350

4254

 

 

10

 

 

 

10

065B7514

16

400

5000

 

 

 

 

 

8

065B7515

 

 

 

 

 

 

18

450

6547

 

 

 

 

 

/

7

065B7516

20

500

7800

 

 

 

 

 

 

065B7517

 

 

 

 

 

 

 

24

600

11269

 

 

 

 

 

 

5

065B7518

Dimensions

˝

A

B

C

D

Weight

 

 

 

 

 

 

 

 

 

 

(DN)

(mm)

(mm)

(mm)

(kg)

 

 

 

 

 

 

 

 

 

 

2

50

54

60

109

1.2

 

 

 

 

 

 

 

 

 

 

2 ½

65

54

73

129

1.8

 

 

 

 

 

 

 

 

 

 

3

80

57

89

144

2.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

100

64

114

164

3.9

 

 

 

 

 

 

 

 

 

 

5

125

70

141

194

5.8

 

 

 

 

 

 

 

 

 

 

6

150

76

168

220

8

 

 

 

 

 

 

 

 

 

 

8

200

95

219

275

14

 

 

 

 

 

 

 

 

 

 

10

250

108

273

330

22

 

 

 

 

 

 

 

 

 

 

12

300

143

324

380

34

 

 

 

 

 

 

 

 

 

 

14

350

184

356

440

70

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

16

400

191

410

491

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

450

203

457

541

118

 

 

 

 

 

 

 

 

 

 

20

500

213

508

596

180

 

 

 

 

 

 

 

 

 

 

24

600

222

610

698

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© Danfoss | 2019.04

VD.BO.N2.02 | 1

Danfoss NVD 805 Data sheet

Data sheet

Danfoss NVD 805

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pos.

Description

 

 

 

Material

 

EURO

ANSI

 

 

 

 

 

Casing DN50-150

 

 

Cast iron + epoxy

EN-GJL-250

ASTM A 48 35 B

 

 

 

 

1

DN200-300&400

 

 

Ductile iron + epoxy

EN-GJS-400.15

ASTM A 536 65-45-12

 

 

 

 

 

*DN350&450-600

 

 

Cast iron + epoxy

EN-GJL-250

ASTM A 48 35 B

 

 

 

 

2

Plates

 

 

 

Aluminium bronze

CuAl10Fe5Ni5

C95400

 

 

 

 

3

Seal DN50-300&400

EPDM

 

 

 

 

 

DN350&450-600

 

 

NBR (nitrile)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Spring

 

 

 

Stainless steel

X5CrNiMo17-12-2

AISI 316

 

 

 

 

5

Steam DN50-300&400

Stainless steel

X3CrNiMo17-13-3

AISI 316

 

 

 

 

 

DN350&450-600

 

 

 

 

 

X5CrNi18-10

AISI 304

 

 

 

 

6

Bearing

 

 

 

PTFE

 

 

 

 

 

7

Eye bolt DN>150

 

 

Steel XC15

 

 

 

 

 

8

Plugs

 

 

 

Brass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Headloss diagram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DN

 

Opening pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm)

KV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ζ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(m3/h)

 

 

 

 

 

 

 

 

˝

 

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

50

 

 

 

 

 

 

39.40

6.30

 

 

 

 

 

 

 

2 1/2

 

65

 

 

 

 

 

 

83.00

4.10

 

 

 

 

 

 

 

3

 

80

 

 

 

 

 

 

138.00

3.40

 

 

 

 

 

 

 

4

 

100

 

 

 

 

 

 

250.00

2.50

 

 

 

 

 

 

 

5

 

125

 

 

 

 

 

 

505.00

1.45

 

 

 

 

 

 

 

6

 

150

 

 

 

 

 

 

891.00

1.00

 

 

 

 

 

 

 

8

 

200

 

 

Near 0

1510.0

1.10

 

 

 

 

 

 

 

10

 

250

 

 

2746.00

1.10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

300

 

 

 

 

 

 

3936.00

1.10

 

 

 

 

 

 

 

14

 

350

 

 

 

 

 

 

4254.00

1.30

 

 

 

 

 

 

 

16

 

400

 

 

 

 

 

 

5000.00

1.60

 

 

 

 

 

 

 

18

 

450

 

 

 

 

 

 

6547.00

1.50

 

 

 

 

 

 

 

20

 

500

 

 

 

 

 

 

7800.00

1.60

 

 

 

 

 

 

 

24

 

600

 

 

 

 

 

 

11269.00

1.60

 

 

 

 

 

 

Direction for use:

Solid line: Valve completely open

Dotted line: opening stage of valve

PSI ∆P M/CE

DN

Debit m3/h

Flow gallon/min

2 | VD.BO.N2.02

© Danfoss | DHS-SRMT/SI | 2019.04

Loading...