MP 12 Hand Pumps
OPERATION This is a manually operated uni-directional pump.
These small displacement hand pumps are used typically for piloting the operation of small hydraulic cylinders or valves. These pumps can be mounted inline using the standard housing or in custom HICs. For smooth operation, inlet lines should not be excessively long, and the vertical distance between pump and tank level no more than 300 mm (12 inch).
These pumps can work in outdoor applications if the ambient air is not contaminated by powder and dust.
SPECIFICATIONS
DIMENSIONS
mm [in]
Size 12
3
Displacement Per Stroke
Max. pressure
NCS Cavity NCS12/2
Max tightening torque
cm [in3]
bar [psi]
Nm [lbf•in]
5 [0.305] 315 [4569]
80 [708]
MP12 detail drawing
SCHEMATIC
BC332376486121en-000101 • February 2020
AC - 8
Cartridge Valves Accessories Technical Information
MP 12 Hand Pumps
ORDERING INFORMATION
Example of designation MP 12
MP 12 / GL - T500 - G1/2 - V
00 = without handle
GL = with handle
T500 = extension
Housing Part #502500613
Seals
V = Viton Omit = Buna N
Standard housing
G1/2 = 1/2” BSP
00 = Cartridge only