adapter plate. For information refer to Prepare Gasket
®
DriveMotor FCP 106 and FCM 106 Operating
in VLT
Instructions.
Crimp terminals. Order numbers from manufacturer
•
TE (AMP standard power timer contacts):
927827-1 (0.5-1 mm2) [AWG 20-17]
•
927833-1 (1.5-2.5 mm2) [AWG 15.5-13.5]
•
927824-1 (2.5-4 mm2) [AWG 13-11]
•
1.1.3 Safety Instructions
For important information about safety precautions for installation, refer to VLT
Instructions
®
DriveMotor FCP 106 and FCM 106 Operating
WARNING
DISCHARGE TIME
The frequency converter contains DC-link capacitors, which
can remain charged even when the frequency converter is
not powered. Failure to wait the specified time after power
has been removed before performing service or repair work,
could result in death or serious injury.
1.Stop motor.
2.Disconnect AC mains, permanent magnet type
motors, and remote DC-link power supplies,
including battery back-ups, UPS, and DC-link
connections to other frequency converters.
3.Wait for the capacitors to discharge fully, before
performing any service or repair work. The duration
of waiting time is specified in Table 1.1.
Voltage
[V]
3x4000.55–7.54
High voltage can be present even when the warning LED indicator