Danfoss Modified Cover Material Installation guide

Danfoss Modified Cover Material Installation guide

Technical Info

Modified Cover Material

220 - 240V / 50Hz Compressors

In the latest standard “Safety of household and similar electrical appliances, IEC60335-1, Edition 4” the flammability safety demands have been changed.

This new standard becomes e ective in EU (EN 60335-1) from October 2005 for light commercial appliances and from October 2006 for household appliances. Other countries can have di erent schedules.

Danfoss will change the cover material according to the table to comply with this new standard. The cover code nos. will not be changed.

Our existing Capron 8202 covers would normally (e .g. with PTC in a household appliance) comply with this new standard. Generally, this material is acceptable if electrical connections (≥0.2 Amps) under the cover are placed ≥ 3 mm from the cover. However, if e.g. a special wiring of a HST start equipment (relay and not PTC) is used, the distance can be less than 3 mm.

Therefore, Danfoss will change the material of the cover in connection with our TL, NL, and FR compressors for 220-240V/50Hz operation from Capron 8202 to Ultramid B3S and in connection with our PL, TF, NF, FF, and SC compressors for 220-240V/50Hz operation to Noryl SE1.

The change of material will take place by the end of September 2005atthelatest.

In case of the standard Ultramid cover (code no. 103N2010) for TL, NL, and FR it is permissible that an inside electrical connection touches the cover. However, there has to be a certain free space outside thecover(ø20x50mmtoelectrical connections). If this is not the case, the “disturbing” external part has tobeofnon-flammablematerialor it has to be able to pass the needle flame test.

220 - 240V / 50Hz

 

Material

Compressor type

Cover code no.

Today

New

PL

103N0491

Capron 8202

Noryl SE1***

TL, NL, FR

Standard = 103N2010

Capron 8202

Ultramid B3S**

Special = 103N2011

 

Noryl SE1***

 

 

TF, NF, SF

117U1023

Capron 8202

Noryl SE1***

SC

103N2009

Capron 8202

Noryl SE1***

Terminal board*

117U1022

Capron 8202

Noryl SE1***

TheNorylcover103N2011hastobeusedif

•CompressorandappliancehavetobeULapproved(e.g.for 220V60Hz applications)or

Flammablepartsaresurroundingthecover,insideø20x50mmtoelectricalconnections (≥0.2Amps)andanelectricalconnectioniscloserthan3mmtothecover.

* = special electric equipment (please see literature“Electrical Equipment for Compressors”)

**= GWFI 850°C and 2 sec<GWT750°C<60 sec / cover will be identified with a“W”printed on the material

***= GWFI 850°C and GWT750°C<2 sec / cover will be identified with“PPO”printed on the material

Danfosscanacceptnoresponsibilityforpossibleerrorsincatalogues,brochuresandotherprintedmaterial.Danfossreservestherighttoalteritsproductswithoutnotice.Thisalsoappliestoproductsalready on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Compressors GmbH

REFRIGERATION AND AIR CONDITIONING

Mads Clausen Str. 7

D-24939 Flensburg / Germany compressors.danfoss.com

DEHC.EI.200.D1.02/520N0207 Produced by Danfoss Compressors, DEHC6093, 09.2005