Danfoss Modified Cover Material Installation guide

Modified Cover Material
220 - 240V / 50Hz Compressors
Technical Info
In the latest standard “Safety of household and similar electrical appliances, IEC60335-1, Edition 4” the flammability safety demands have been changed. This new standard becomes effective in EU (EN 60335-1) from October 2005 for light commercial appliances and from October 2006 for household appliances. Other countries can have different schedules. Danfoss will change the cover material according to the table to comply with this new standard. The cover code nos. will not be changed. Our existing Capron 8202 covers would normally (e .g. with PTC in a household appliance) comply with this new standard. Generally, this material is acceptable if electrical connections (≥0.2 Amps) under the cover are placed ≥ 3 mm from the cover. However, if e.g. a special wiring of a HST start equipment (relay and not PTC) is used, the distance can be less than 3 mm.
Therefore, Danfoss will change the material of the cover in con­nection with our TL, NL, and FR compressors for 220-240V/50Hz operation from Capron 8202 to Ultramid B3S and in connection with our PL, TF, NF, FF, and SC compressors for 220-240V/50Hz operation to Noryl SE1.
The change of material will take place by the end of September 2005 at the latest.
220 - 240V / 50Hz Material Compressor type Cover code no. Today PL 103N0491 Capron 8202 Noryl SE1***
TL, NL, FR
TF, NF, SF SC 103N2009 Capron 8202 Noryl SE1*** Terminal board*
The Noryl cover 103N2011 has to be used if
• Compressor and appliance have to be UL approved (e. g. for 220V 60Hz applications) or
• Flammable parts are surrounding the cover, inside ø20x50 mm to electrical connections (≥0.2 Amps) and an electrical connection is closer than 3 mm to the cover.
* = special electric equipment (please see literature “Electrical Equipment for Compressors”)
** = GWFI 850°C and 2 sec<GWT750°C<60 sec / cover will be identified with a “W” printed on the material
*** = GWFI 850°C and GWT750°C<2 sec / cover will be identified with “PPO” printed on the material
Standard = 103N2010 Capron 8202 Ultramid B3S**
Special = 103N2011 Noryl SE1***
117U1023 Capron 8202 Noryl SE1***
117U1022 Capron 8202 Noryl SE1***
In case of the standard Ultramid cover (code no. 103N2010) for TL, NL, and FR it is permissible that an inside electrical connection touch es the cover. However, there has to be a certain free space outside the cover (ø 20x50 mm to electrical connections). If this is not the case, the “disturbing” external part has to be of non-flammable material or it has to be able to pass the needle flame test.
New
-
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Compressors GmbH
Mads Clausen Str. 7 D-24939 Flensburg / Germany
REFRIGERATION AND AIR CONDITIONING
DEHC.EI.200.D1.02/520N0207 Produced by Danfoss Compressors, DEHC6093, 09.2005
compressors.danfoss.com
Loading...