Danfoss MCI 15BP Installation guide [da]

Instructions
!
MCI 15BP
047C0425
Montering - Mounting - Montage Mål - Dimensions - Abmessungen
Soft Start Motor Controller
047C0425
Forbindelse - Wiring - Verdrahtung
75°C
Kabel/ Wire mm2 (AWG) mm2 (AWG)
0.75 - 4
(18 - 12)
2 x 1
(2 x 18)
0.75 - 6
(18 - 10)
2 x 0.75 - 2.5
(2 x 18 - 14)
0.75 - 6
(18 - 10)
2 x 0.75 - 1.5
(2 x 18 - 16)
Pozidrive 1
0.5 Nm max.
4.4 lb-in max.
4 mm
0.5 Nm max.
4.4 lb-in max.
- Vigtigt: (Overhold max. skruedrejningsmomenter)
- Important: (Observe the maximum screw torque limits)
- Wichtig: (Max. Drehmoment beachten)
0.5 - 1.5 (20 - 16)
2 x 0.5 - 0.75
(2 x 20 - 18)
0.5 - 1.5 (20 - 16)
2 x 0.5 - 1.5 (2 x 20 - 16)
0.5 - 1.5 (20 - 16)
2 x 0.5 - 1.5 (2 x 20 - 16)
N.A.
3 mm
0.4 Nm max.
3.5 lb-in max.
DK Luftstrøm må ikke blokeres UK Airflow should not be blocked D Luftstrom muß ungehindert fließen
Info for UK customers only:Danfoss Ltd. Oxford Road, UB9 4LH Denham, UK
A2
A1
Do not connect power factor correction capacitors to the output.
P.S.: This product has been designed for class A equipment. Use of the product in domestic environment may cause radio interference, in which case the user may be required to employ additional mitigation methods.
Control voltage 24 - 230 V AC/DC (208 V AC) 24 - 400 V AC/DC (400 V AC) 24 - 480 V AC/DC (480 V AC)
Info for UK customers only:Danfoss Ltd. Oxford Road, UB9 4LH Denham, UK
©Danfoss A/S 12-2020 (RA-MC/mr) AN00008642308601-000401 / 1
Instructions
047C0425
Indstilling - Settings - Einstellungen
Bemærkninger - Remarks - Bemerkungen
Dansk English Deutsch
Anvend 2 mm x 0.5 mm skruetrækker.
Vær forsigtig ikke at idstille drejekon-
takterne imellem klik.
NB!
Motor Controlleren aflæser tid og
moment justeringen i stop tilstand.
MCI 15BP
Soft Start Motor Controller
Use 2 mm x 0.5 mm screwdriver.
Make sure that the switches click
into position, otherwise time and torque settings will not be correct.
The motor controller will read time and torque settings in the off state.
Repeated starts may trip motor protection relay.
047C0425
Schraubenzieher 2 mm x 0.5 mm
verwenden.
Schalter müssen einrasten, um korrekte Funktion zu gewährleisten.
Eingestellte Werte werden im aus­ geschalteten Zustand abgelesen.
Mehrfache Starts können Motor­ schutzrelais auslösen.
Startmoment indstilling - Initial torque setting - Einstellung der Startleistung
1. Indstil Ramp-up kontakt til max.
2. indstil Ramp-down kontakt til min.
3. Indstil Initial Torque kontakt til min.
4. Påtryk signalspænding i et par sekun­ der, hvis ikke motorakslen roterer øjeblikkelig efter start juster Initial torque en deling op. Gentag indtil motoraksel roterer øjeblikkelig efter start.
Hvis Initial torque justeringen ikke er tilstrækkeligt til at starte motoren, er det nødvendigt at anvende Kick-start.
1. Indstil Ramp-up tiden til max.
2. Indstil Ramp-down tiden til min.
3. Indstil Initial torque til minimum kick- start moment.
4. Påtryk signalspænding i et par sekun­der. Hvis belastningen stopper umid­delbart efter Kick-start perioden juster Inititial torque en deling op. Gentag indtil motoraksel fortsætter med at rotere efter Kick-start perioden.
1. Set Ramp-up switch to max.
2. Set Ramp-down switch to min.
3. Set Initial torque switch to min.
4. Apply control signal for a few seconds. If the load does not rotate immediately increase the Initial torque for one step and try again. Repeat until the load starts to rotate immediately on start up.
If the maximum Initial torque setting is not sufficient to start the motor, it is necessary to use Kick-start
1. Set Ramp-up switch to max.
2. Set Ramp-down switch to min.
3. Set Initial torque switch to min. kick start torque.
4. Apply control signal for a few seconds. If the load stops right after the kick start increase the Initial torque for one step and try again. Repeat until the load continues to rotate afte the "kick".
Start rampe indstilling - Ramp up settings - Einstellung der Startanstiegszeit
1. Indstil Ramp-up tiden til max. og start motor.
2. Gradvis nedsæt Ramp-up tiden indtil motor og belastning netop overbe­ lastes.
3. Juster Ramp-up tiden en deling op.
1. Set Ramp-up switch to max. and start motor.
2. Decrease the Ramp-up time until mechanical surge is observed.
3. Increase Ramp-up time one step.
1. Ramp-up Schalter auf max. stellen
2. Ramp-down Schalter auf min. stellen
3. Initial torque Schalter auf min. stellen
4. Steuersignal einige Sekunden betäti­ gen. Falls der Motor nicht sofort an­ läuft Initital torque schrittweise erhö- hen, bis der Motor anläuft.
Falls Initial torque max. Einstellung nicht ausreicht um den Motor zu starten, muß Kick-start verwendet werden.
1. Ramp-up Schalter auf max. stellen
2. Ramp-down Schalter auf min. stellen
3. Initial torque Schalter auf min. Kick- start stellen.
4. Steuersignal einige Sekunden betäti­ gen. Falls der Motor sofort wieder stoppt, Initial torque schrittweise er- höhen, bis der Motor sofort nach dem "Kick" anläuft.
1. Ramp-up Schalter auf max. stellen.
2. Ramp-up Zeit solange verkürzen bis Überbelastung beobachtet wird.
3. Ramp-up Zeit um einen Schritt erhö­ hen.
Stop rampe indstilling - Ramp down settings - Einstellung der Startanstiegszeit
1. Indstil Ramp-down tiden til max. og afbryd signalspændingen.
2. Gradvis nedsæt Ramp-down tiden indtil motor og belastning netop over­ belastes.
3. Juster Ramp-down tiden en deling op.
1. Set Ramp-down switch to max. and switch off the control voltage.
2. Decrease the Ramp-down time until mechanical surge is observed.
3. Increase Ramp-up time one step.
1. Ramp-down Schalter auf max. stel­ en und Steuersignal ausschalten.
2. Ramp-down Zeit solange verkürzen bis Überbelastung beobachtet wird.
3. Ramp-down Zeit um einen Schritt erhöhen.
AN00008642308601-000401 ©Danfoss A/S 12-2020 (RA-MC/mr) / 2