Danfoss MCHE D1400-C Data sheet

Data Sheet
Micro Channel Heat Exchanger Type MCHE D1400-C
Condenser – standard series
D1400-C MCHE condenser is ideal for use in many dierent applications, such as chillers, residential AC and commercial split/roof tops.
MCHEs have an ingeniously simple all­aluminum design that is not only lightweight but also prevents galvanic corrosion.
The refrigerant-carrying tubes are formed to optimize heat transfer, enabling the production of more compact, but equally eective, cooling solutions. The smart louvered n design maximizes surface contact, reducing the air­side pressure loss, improving eciency and reducing noise levels.
Features:
• Reduce refrigerant system charge
• Improve eciency – More compact/better COP/increased capacity
• Cost - Less sensitive to uctuations in raw material prices
• Better corrosion characteristics due to all­aluminum design
AI280341601519en-000801
Model
Coil length
Coil height
Core depth
Fin pitch
Inlet ID
diameter
Outlet ID diameter
Continuous
operating
temperature
Max. working
pressure
D1400-C
780 (mm)
30.7 (in)
771 (mm)
30.4 (in)
16 (mm)
0.6 (in)
1.1 (mm) 23 (FPI)
9.7 (mm)
0.38 (in)
9.7 (mm)
0.38 (in)
-40 °C / 121 °C
-40 °F / 250 °F
45 (bar)
650 (psi)
Air Velocity
Performance [KW/Btu/h×1000]
[m/s]
R410A
R134a
[ft/min]
Δ=10 K / 18 °F
Δ=15 K / 27 °F
Δ=20 K / 36 °F
Δ=25 K/ 45 °F
Δ=10 K / 18 °F
Δ=15 K / 27 °F
Δ=20 K / 36 °F
Δ=25 K/ 45 °F
1.0/197
5.64/19.24
8.69/29.65
11.73/40.02
15.15/51.69
5.43/18.53
8.36/28.52
11.27/38.45
14.17/48.35
1.5/295
7.79/26.58
12.02/41.01
16.76/57.19
21.29/72.64
7.43/25.35
11.5/39.24
15.55/53.06
19.57/66.77
2.0/394
9.66/32.96
14.93/50.94
21.05/71.82
26.75/91.27
9.15/31.22
14.2/48.45
19.23/65.61
24.77/84.52
2.5/492
11.32/38.62
18.26/62.3
24.93/85.06
31.72/108.23
10.65/36.34
16.56/56.5
22.49/76.74
29.08/99.22
3.0/591
12.82/43.74
20.86/71.17
28.5/97.24
36.26/123.72
11.98/40.88
18.69/63.77
26.17/89.29
32.96/112.46
Air Velocity
Performance [KW/Btu/h×1000]
[m/s]
R404A
R407C
[ft/min]
Δ=10 K / 18 °F
Δ=15 K / 27 °F
Δ=20 K / 36 °F
Δ=25 K/ 45 °F
Δ=10 K / 18 °F
Δ=15 K / 27 °F
Δ=20 K / 36 °F
Δ=25 K/ 45 °F
1.0/197
5.58/19.04
8.62/29.41
11.99/40.91
15.2/51.86
3.68/12.56
7/23.88
10.13/34.56
13.24/45.17
1.5/295
7.64/26.07
11.82/40.33
16.76/57.19
21.26/72.54
5/17.06
9.66/32.96
14.01/47.8
18.6/63.46
2.0/394
9.39/32.04
15.35/52.37
20.95/71.48
26.63/90.86
6.12/20.88
11.94/40.74
17.39/59.33
23.44/79.98
2.5/492
10.91/37.22
18.11/61.79
24.72/84.34
31.42/107.21
7.1/24.23
13.95/47.6
20.87/71.21
27.68/94.44
3.0/591
12.27/41.87
20.6/70.29
28.15/96.05
35.78/122.08
7.92/27.02
15.79/53.88
23.91/81.58
31.53/107.58
Micro Channel Heat Exchanger, type MCHE D1400-C
Product specication
Technical data
Table 1: Technical data
Weight / internal volume
Coil weight: 4.541 kg / 10.0 lb Internal volume: 0.74 l / 45.16 in
3
Material specication
MPE Tube: AA3102 Fins: AA3003Mod clad with AA4343 Manifold: AA3003 clad with AA4343 Side plate: AA3003 Inlet/Outlet tubes: Copper
Performance data
Table 2: Performance data of R410A and R134a
Table 3: Performance data of R404A and R407C
© Danfoss | Climate Solutions | 2021.02 AI280341601519en-000801 | 2
Loading...
+ 3 hidden pages