Data Sheet

Micro Channel Heat Exchanger

Type MCHE D1300-C

Condenser – standard series

D1300-C is ideal for use in a number of various applications, such as Residential AC, Condensing units, Air driers, Cabinet cooling and Indoor display.

MCHEs have an ingeniously simple allaluminum design that is not only lightweight but also prevents galvanic corrosion.

The refrigerant-carrying tubes are formed to optimize heat transfer, enabling the production of more compact, but equally effective, cooling solutions. The smart louvered fin design maximizes surface contact, reducing the airside pressure loss, improving efficiency and reducing noise levels.

Features:

• Reduce refrigerant system charge

• Improve efficiency – More compact/better COP/increased capacity

• Cost - Less sensitive to …uctuations in raw material prices

• Better corrosion characteristics due to allaluminum design

AI133486416424en-000701

Micro Channel Heat Exchanger, type MCHE D1300-C

Product speci€cation

Technical data

Table 1: Technical data

 

 

 

 

 

Inlet ID

Outlet ID

Continuous

Max. working

Model

Coil length

Coil height

Core depth

Fin pitch

operating

diameter

diameter

pressure

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

D1300-C

552 (mm)

517 (mm)

16 (mm)

1.1 (mm)

9.7 (mm) 0.38

8.2 (mm)

-40 °C / 121

°C

45 (bar)

21.7 (in)

20.3 (in)

0.6 (in)

23 (FPI)

(in)

0.32 (in)

-40 °F / 250

°F

650 (psi)

 

 

 

 

 

 

 

 

 

 

 

Weight / internal volume

Coil weight: 2.174 kg / 4.8 lb

Internal volume: 0.4 l / 24.41 in3

Material speci€cation

MPE Tube: AA3102

Fins: AA3003Mod clad with AA4343

Manifold: AA3003 clad with AA4343

Side plate: AA3003

Inlet/Outlet tubes: Copper

Performance data

Table 2: Performance data of R410A and R134a

Air Velocity

 

 

 

Performance [KW/Btu/h×1000]

 

 

 

[m/s]

 

R410A

 

 

R134a

 

[ft/min]

Δ=10 K / 18 °F

Δ=15 K / 27 °F

Δ=20 K / 36 °F

Δ=25 K/ 45 °F

Δ=10 K / 18 °F

Δ=15 K / 27 °F

Δ=20 K / 36 °F

Δ=25 K/ 45 °F

1.0/197

2.08/7.1

3.73/12.73

5.08/17.33

6.42/21.91

2.3/7.85

3.61/12.32

4.91/16.75

6.2/21.15

1.5/295

3.27/11.16

5.15/17.57

7.02/23.95

9.23/31.49

3.15/10.75

4.98/16.99

6.78/23.13

8.57/29.24

2.0/394

4.05/13.82

6.39/21.8

9.04/30.84

11.61/39.61

3.89/13.27

6.16/21.02

8.41/28.69

10.65/36.34

2.5/492

4.75/16.21

7.49/25.56

10.74/36.64

13.79/47.05

4.54/15.49

7.22/24.63

9.85/33.61

12.49/42.62

3.0/591

5.37/18.32

8.49/28.97

12.49/42.62

15.79/53.88

5.13/17.5

8.16/27.84

11.18/38.15

14.41/49.17

 

 

 

 

 

 

 

 

 

Table 3: Performance data of R404A and R407C

Air Velocity

 

 

 

Performance [KW/Btu/h×1000]

 

 

 

[m/s]

 

R404A

 

 

R407C

 

[ft/min]

Δ=10 K / 18 °F

Δ=15 K / 27 °F

Δ=20 K / 36 °F

Δ=25 K/ 45 °F

Δ=10 K / 18 °F

Δ=15 K / 27 °F

Δ=20 K / 36 °F

Δ=25 K/ 45 °F

1.0/197

2.37/8.09

3.71/12.66

5.04/17.2

6.55/22.35

1.44/4.91

2.98/10.17

4.37/14.91

5.74/19.58

1.5/295

3.23/11.02

5.08/17.33

6.91/23.58

9.27/31.63

1.87/6.38

4.1/13.99

6.03/20.57

7.95/27.13

2.0/394

3.96/13.51

6.26/21.36

9.07/30.95

11.65/39.75

2.51/8.56

5.08/17.33

7.49/25.56

9.88/33.71

2.5/492

4.61/15.73

7.29/24.87

10.75/36.68

13.79/47.05

2.93/10

5.93/20.23

8.78/29.96

11.67/39.82

3.0/591

5.18/17.67

8.31/28.35

12.28/41.9

15.77/53.81

3.27/11.16

6.7/22.86

9.94/33.92

13.73/46.85

 

 

 

 

 

 

 

 

 