Fact Sheet
VLT® HVAC Basic Drive FC 101
Convenient and compact control
IP54
Quiet
cooling fan operation
over the entire power
range
IP20
Efficient control of
induction and permanent
magnet motors in all HVAC
applications
Product range
3 x 200-240 V ...................................0.25-45 kW
3 x 380-480 V ...................................0.37-90 kW
3 x 525-600 V ..................................... 2.2-90 kW
Optimized for basic operation
of fans, pumps and compressors, the
VLT® HVAC Basic Drive has built-in
functions that reduce initial costs and
increase productivity.
Available enclosure ratings
IP20
IP21/UL Type 1 (separate option kit)
IP54
This drive is the most compact unit
in its class, and can deliver up to 25%
energy savings. Integrated DC coils reduce harmonics without the extra cost
and space required for external devices.
Feature Benefit
All built-in – low investment
Most common HVAC protocols for BMS
controller connectivity are embedded
Built-in PI controller No external PI controller required
Smart Logic Controller Often makes PLC unnecessary
Sensorless pump control No need for external pressure transmitter
Save energy – less operation cost
Flow compensation function Saves energy
Automatic Energy Optimizer function Saves additional 5-15% energy
PM motor control in open loop Increased efficiency especially at part load
Sleep mode Saves energy and extends lifetime
Unequalled robustness – maximum uptime
Robust single enclosure Maintenance-free
Unique variable-speed cooling concept with no
forced air flow over electronics
Max ambient temp. up to 50° C No external cooling
Flying Start Reduced mechanical wear on equipment
Fire override mode Enhanced safety
Thermistor input Prevents motor overheating
User friendly – save commissioning and operating cost
Operate both PM and induction motors Versatile, only one drive type required
Easy connectability and start-up wizard Effective commissioning and operation
Alpha-numeric display/improved HMI
Cooling fan operation adjusts precisely to load Silent or low noise level only
Auto restart Saves time and money
Bypass frequencies Less noise and vibrations/resonances
Global HVAC support organization Local service – globally
Built-in DC coils and EMC filters – no harmonic concerns
Built-in EMC filter Meets protection class C1, C2 or C3
Integrated DC choke Small power cables. Meets EN 61000-3-12
Fewer extra gateway solutions needed
Problem-free operation in harsh environments
Display in multiple languages and
metric/imperial units
drives.danfoss.com
Easy commissioning
n Configure with a start-up wizard
n Easy-to-program parameters
n Alphanumeric display
n Hand – Off – Auto keys
n Status LCDs
n Easy to install and wire up
n 7 languages and numeric
programming
Your choice
n Enclosures: IP20/Chassis or
IP21/Type 1 or IP54
n Optional harmonic filters
for 5% or 10% THDi
n Minimum 25 m C3
as standard built-in
Optional: C1/C2 filters
Specifications
Mains supply (L1, L2, L3)
Supply voltage
Supply frequency 50/60 Hz
Displacement power factor (cos φ) Near unity (> 0.98)
Switching frequency on input supply L1, L2, L3 1 time/minute max.
Output data (U, V, W)
Output voltage 0-100% of supply voltage
Switching on output Unlimited
Ramp times 1-3600 sec.
Open/closed loop 0-400 Hz
Digital inputs
Programmable digital inputs 4
Logic PNP or NPN
Voltage level 0-24 V DC
Analog inputs
Analog inputs 2
Modes 1 voltage or current
Voltage level 0 V to +10 V (scaleable)
Current level 0/4 to 20 mA (scaleable)
Analog output (can be used as digital output)
Programmable analog outputs 2
Current range at analog output 0/4 to 20 mA
Relay outputs
Programmable relay outputs 2 (240 VAC, 2 A and 400 VAC, 2 A)
Fieldbus communication
Standard built-in:
BACnet mstp
FC Protocol
200–240 V ±10%
380–480 V ±10%
525–600 V ±10%
N2 Metasys
FLN Apogee
Modbus RTU
Dimensions
Power
Frame IP Class 3 x 200-240 V 3 x 380-480 V 3 x 525-600 V Incl. decoupling plate
H1 IP20 0.25-1.5 kW/0.3-2 HP 0.37-1.5 kW/0.5-2 HP - 195/7.7 273/10.7 75/2.9 168/6.6
H2 IP20 2.2 kW/3 HP 2.2-4 kW/3-5.4 HP - 227/8.9 303/11.9 90/3.5 190/7.5
H3 IP20 3.7 kW/5 HP 5.5-7.5 kW/7.5-10 HP - 255/10.0 329/13.0 100/3.9 206/8.1
H4 IP20 5.5-7.5 kW/7.5-10 HP 11-15 kW/15-20 HP - 296/11.7 359/14.1 135/5.3 241/9.5
H5 IP20 11 kW/15 HP 18.5-22 kW/25-30 HP - 334/13.1 402/15.8 150/5.9 255/10.0
H6 IP20 15-18.5 kW/20-25 HP 30-45 kW/40-60 HP 18.5-30 kW/25-40 HP 518/20.4 595/23.4-635/25.0 239/9.4 242/9.5
H7 IP20 22-30 kW/30-40 HP 55-75 kW/75-100 HP 37-55 kW/50-75 HP 550/21.7 630/24.8-690/27.2 313/12.3 335/13.2
H8 IP20 37-45 kW/50-60 HP 90 kW/125 HP 75-90 kW/100-125 HP 660/26.0 800/31.5 375/14.8 335/13.2
H9 IP20 – – 2.2-7.5 kW/3-10 HP 372/14.6 374/14.7 130/5.1 205/8.0
H10 IP20 – – 11-15 kW/15-20 HP 475/18.7 419/16.5 165/6.5 249/9.8
I2 IP54 – 0.75-4 kW/1-5.4 HP – 332/13.1 – 115/4.5 225/8.8
I3 IP54 – 5.5-7.5 kW/7.5-10 HP – 368/14.5 – 135/5.3 237/9.3
I4 IP54 – 11-18.5 kW/15-25 HP – 476/18.7 – 180/7.1 290/11.4
I6 IP54 – 22-37 kW/30-50 HP – 650/25.6 – 242/9.5 260/10.2
I7 IP54 – 45-55 kW/60-75 HP – 680/26.8 – 308/12.1 310/12.2
I8 IP54 – 75-90 kW/100-125 HP – 770/30.3 – 370/14.6 335/13.2
DKDD.PFP.100.A4.02 © Copyright Danfoss Drives | 2017.07
(kW/HP)
Height
(mm/inch)
Width
(mm/inch)
Depth
(mm/inch)
EtherNet/IP™ and DeviceNet™ are trademarks of ODVA, Inc.