Danfoss EKA 202, EKA 203 Installation guide

Installation Guide

Bluetooth Adapter

Type EKA 202 & EKA 203

Bluetooth Adapter (EKA 202 & EKA 203) is a plug in type device for ERC and EETa range of controllerstoprovidebluetoothconnectivitywithcompanionmobileapplication'KoolConnect'.

Bluetooth Low Energy 5.2

Simple Plug and Play module

• Powered from controller

Scan

• Data logging for 15 days

to

connect

• Real time clock with power back up option

<![if ! IE]>

<![endif]>Danfoss 80G8346

 

080R4219

AN404136884216en-000101

Fig. 1: EKA 202/203

Technical specifications:

Specifications

EKA 202

 

EKA 203

 

 

 

 

 

Input voltage

5 V DC / 12 V DC

 

5 V DC / 12 V DC

 

 

 

 

 

Max Current

70 mA

 

76 mA

 

 

 

 

 

Bluetooth version

5.2

 

5.2

 

 

 

 

 

Bluetooth range (without any obstruction around)

10 m

 

10 m

 

 

 

 

 

Data storage duration

15 days

 

15 days

 

 

 

 

 

RTC power back up

No power backup

 

36 hours (approx.)

 

 

 

 

 

Communication interface with controller

UART, One wire

 

UART, One wire

 

 

 

 

 

Operating temperature

-25 – +55 °C

 

-25 – +55 °C

 

 

 

 

Maximum humidity

<90% RH (Non-condensing)

<90% RH (Non-condensing)

 

 

 

 

 

Storage temperature

-40 – +70 °C

 

-40 – +70 °C

 

 

 

 

 

Ordering code

Bluetooth adapter

080N0022 (Single Pack)

| 080N0026 (I Pack)

080N0023 (Single Pack) | 080N0027 (I Pack)

 

 

 

 

Interface cable

080N0329 (ERC 11x) |

080N0327 (ERC21x) |

080N0325 (EETa)

 

Supported Controllers

ERC11x, ERC21x (080G34xx series only) and EETa

 

 

 

 

Approvals1)

CE, UL, FCC, ISED

 

 

1) For latest approval status and other local approvals, please check at danfoss.com or contact your local Danfoss representative.

Dimensions (units are in mm)

Fig. 2: Top view

59.6

<![if ! IE]>

<![endif]>ctconne to Scan

B

Fig. 3: Rear view

<![if ! IE]>

<![endif]>Danfoss 80G8311

 

17.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

<![if ! IE]>

<![endif]>35

C

<![if ! IE]>

<![endif]>Danfoss 80G8340

A.Bluetooth Adapter

B.QR code chip

C.TTL port for connection with controller

Procedure for adapter installation

1.Detach the QR code chip from the Bluetooth Adapter by breaking. The QR code chip is used for pairing with mobile application.

<![if ! IE]>

<![endif]>ctnneo otcScan

<![if ! IE]>

<![endif]>Danfoss80G8345

2.Attach the QR code chip to the door or any clean part of the cabinet that can be easily accessed for the pairing procedure.

Scan to connec

t

 

<![if ! IE]>

<![endif]>Danfoss 80G8315

<![if ! IE]>

<![endif]>Danfoss 80G8315

© Danfoss | Climate Solutions | 2022.02

AN404136884216en-000101 | 1

Danfoss EKA 202, EKA 203 Installation guide

3.Secure the Bluetooth Adapter in a convenient location using double sided tape (Fig. 4-5) or by screw mounting (Fig. 6)

Fig. 4

Fig. 5

<![if ! IE]>

<![endif]>Danfoss 80G8313

<![if ! IE]>

<![endif]>Danfoss 80G8314

Fig. 6

<![if ! IE]>

<![endif]>Danfoss 80G8317

4.Power off the controller by switching off the main supply to the controller.

5.Connect the Bluetooth Adapter to communication port of controller using interface cable (Fig. 7)

TTL port in ERC21x and EETa

DI port in ERC11x

Fig. 7

Bluetooth Adapter

Interface

cable

Controller

Note:

<![if ! IE]>

<![endif]>Danfoss 80G8316

Ensure the Bluetooth Adapter is installed away from heating source, direct sunlight, dripping water, dusty environment.

Avoid any obstruction around the adapter that impacts Bluetooth communication.

Interface cable ordered separately for the respective controller to be used for connecting Bluetooth Adapter to Controller.

Power up sequence and connection with mobile application:

Function

Description

Power up the controller connected with Power-up Bluetooth Adapter.

Bluetooth Adapter starts power up initialization (it gets power from connected controller).

 

After power up initialization, the adapter

 

establishes communication with connected

Established

controller and start broadcasting.

communication

 

with controller and

 

broadcasting.

Unsuccessful identification/communication with

 

 

controller.

Connection with mobile

Search and connect broadcasting adapter using

KoolConnect companion app. Click on "Set

app and Real time clock

time" when mobile app shows alert message to

(RTC) update

synchronize the adapter time with mobile time.1)

1) Note:

Illustration

Blue Red Green

<![if ! IE]>

<![endif]>Danfoss80G8341

Green

<![if ! IE]>

<![endif]>Danfoss80G8342

Green

<![if ! IE]>

<![endif]>Danfoss80G8347

Red

<![if ! IE]>

<![endif]>Danfoss80G8343

Blue

<![if ! IE]>

<![endif]>Danfoss80G8344

LED info

White – Blue – Red – Green LED blinking in sequence indicates power up initialization.

After few seconds, Green LED rapid flashes indicating controller detection is in progress.

Green LED slow flashes (1s/1s)

Red LED rapid flashes.

LED turns to constant Blue indicating Bluetooth is connected.

1.Ensure that the module is connected to the mobile app after final power up and installation to finalize the setup properly. If the module is not connected after final power up at customer's site, the module will log the data without the correct time stamp.

2.If the Bluetooth Adapter is changed from one controller model to another (ex: ERC112C to ERC112D or EETa 3W), all the logged data from previous controller are erased and start logging afresh from new controller. The data from previous controller is retained if one code no. is changed to another code no. within the same controller model.

KoolConnect companion mobile app download and connection:

Android version 8.0 or later

 

iOS 11 or later (Iphone 8 & above)

 

 

 

KoolConnect

2 | AN404136884216en-000101

© Danfoss | Climate Solutions | 2022.02

Loading...